background image

5.  trouBLeshootINg

6.  maINteNaNce

 

‰

   WarNINg: Disconnect from mains before cleaning or performing maintenance.

6.1. 

  

Cleaning and user maintenance should be carried out by competent persons.

6.2. 

  

After use and before performing maintenance, unplug and disconnect the battery charger.

6.3.    

Use a dry cloth to wipe all battery corrosion and other dirt or oil from the battery connectors, cords, and the charger case.

6.4. 

  

ensure that all of the charger components are in place and in good working condition, for example, the plastic boots on the battery  

 clips.

6.5. 

  

Servicing does not require opening the unit, as there are no serviceable parts.

6.6.    

All other servicing should be performed by qualified service personnel.

6.7. 

  

If the mains cable is damaged, 

Do Not

 use until repaired.

6.8. 

  

Store the charger unplugged. The cord will still conduct electricity until it is unplugged from the mains.

6.9. 

  

Store inside, in a cool, dry place.

6.10. 

Do Not

 store the connectors clipped together, on or around metal, or clipped to cables. If the charger is moved around the shop or  

 

transported to another location, take care to avoid/prevent damage to the cables, connectors and charger. Failure to do so could result  

 

in personal injury or property damage.

sealey group, Kempson Way, suffolk Business park, Bury st edmunds, suffolk. Ip32 7ar

 01284 757500 

 01284 703534 

 [email protected] 

 www.sealey.co.uk

eNVIroNmeNt protectIoN

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 

a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 

unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 
according to local regulations.

Note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice.

Important

: no liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.

Original Language Version

© Jack Sealey limited

A

UTOCHARGE400HF     Issue 1 22/08/18

Weee reguLatIoNs

Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment 
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid 

waste authority for recycling information.

Charging mode cannot be entered or 

selection cannot be made.

Switch damaged.

Improper operation of switch.

Check charger attachment to battery. 

Note:

 mode can only be changed when the battery is not 

connected. 

Parts support is available for this product. Please log on to  

www.sealey.co.uk, email [email protected] or telephone 01284 757500

 

symptom

solution

no reaction when powered on.

Check item is plugged into mains.

Check AC supply available

Return to Sealey stockist.

Содержание AUTOCHARGE400HF

Страница 1: ...blue only and are marked with The Class II symbol A Connect the BROWN live wire to the live terminal L B Connect the BLUE neutral wire to the neutral terminal N C After wiring check that there are no bare wires and ensure that all wires have been correctly connected 9 9 Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight 8 8 DO NOT connect either w...

Страница 2: ...inals 8 8 DO NOT allow power clamps to touch each other or to make contact with any metallic part of the vehicle 8 8 DO NOT cross connect power leads from charger to battery Ensure positive RED is to positive and negative BLACK is to negative 8 8 DO NOT pull the cables or clamps from the battery terminals 8 8 DO NOT operate within the vicinity of flammable liquids or gases 8 8 DO NOT use charger i...

Страница 3: ... red clamp on the clamp lead is not touching the battery or the fuel line 4 5 2 Connect the negative black clamp to the negative battery post and connect the positive red clamp to the positive battery post or vehicle chassis 4 6 BATTERY NOT CONNECTED TO A VEHICLE 4 6 1 Connect the red clamp to the positive battery post and connect the black clamp to the negative battery post 4 7 PERMANENT CONNECTI...

Страница 4: ...y type switch mode function selection 4 9 LCD Display modes 4 10 LED displayed codes CODE MODE REASON FAULT CODES AUT AUTO MODE SHORT CIRCUIT PROTECTION F01 PUL PULSE MODE OVER VOLTAGE PROTECTION F02 REC RECOND MODE OVER CURRENT PROTECTION F03 FUL FULLY CHARGED OVER TEMPERATURE PROTECTION F04 OVER TIME CHARGING F05 CHE ANALYSIS MODE REVERSE CONNECTION PROTECTION F06 Original Language Version Jack ...

Страница 5: ...nted materials instead of disposing of them as waste All tools accessories and packaging should be sorted taken to a recycling centre and disposed of in a manner which is compatible with the environment When the product becomes completely unserviceable and requires disposal drain any fluids if applicable into approved containers and dispose of the product and fluids according to local regulations ...

Отзывы: