ELECTRONIC DIGITAL HEIGHT GAUGE
Model no:
AK9636D.V2
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAfETy
WARNING! Ensure Health and Safety, local authority and general workshop practice regulations are adhered to when using
tools and equipment.
WARNING! Some edges, in particular the scribe are sharp and caution should be used when handling, store safely in the
storage case when not in use.
8
DO NOT
use the gauge if damaged.
9
Maintain the gauge in good and clean condition for best and safest performance.
9
Keep the work area clean, uncluttered and ensure there is adequate lighting.
9
Maintain correct balance and footing. ensure the floor is not slippery and wear non-slip shoes.
9
Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery. Contain or tie back long hair.
9
Keep children and unauthorised persons away from the work area.
2. INTRODUCTION
Precision ground base with 6 button electronic gauge. Includes fine adjustment control carriage for accurate use. 6-digit lCd read-out
displays in metric or imperial. Supplied with scriber foot and clamp. Powered by CR2032 battery (included) and supplied with storage
case.
3. SpECIfICATION
Measuring range
: .................................... 0 - 300mm / 0 - 12in
Accuracy
: ...................................................0.03mm / 0.0012in
Resolution
: .................................................0.01mm / 0.0001in
Repeatability
: .............................................0.01mm / 0.0005in
1
Power switch
2
mm / inch selection
3
Relative / Absolute
4
Zero setting button
5
+ preset button
6
- preset button
A Scale
B Beam
C Fine adjustment
d lCd display
e Fastening Screw
F Battery lid
G Base
H Scribe
operating temperature: ............................................... 0 - 40ºC
Storage temperature: .............................................. -20 - 70ºC
Max. relative humidity: ...................................................... 80%
4. OpERATION
4.1.
TO fIT SCRIbER
4.1.1.
Place the clamp upon the arm extending from the slider.
4.1.2.
Slot the scriber into the clamp and tighten.
4.2.
Turn the gauge on by pressing the power button (Fig 1.1).
4.3.
Select the desired units of measurement (inch / mm) using the selection button (Fig 1.2).
4.4.
To set the gauge to absolute zero at any point, press the Zero setting button (Fig 1.4).
4.5.
To set the origin to a value other than zero, use the +/- preset buttons (Fig 1.5.6).
4.5.1.
To increase the value of the origin, press the zero setting button and +preset button
simultaneously. The word “set” will flash in the display. To increase the value by
fig.1
1
6
5
2
4
A
B
C
d
e
F
G
H
3
fig.2
Arm
Clamp
Scriber
AK9636d.V2 Issue 2 (HF) 05/10/18
Original Language Version
© Jack Sealey limited
Refer to
instructions