background image

ELECTRONIC DIGITAL HEIGHT GAUGE

Model no:

 AK9636D.V2

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAfETy

 

‰

   WARNING! Ensure Health and Safety, local authority and general workshop practice regulations are adhered to when using  

  tools and equipment.

 

‰

   WARNING! Some edges, in particular the scribe are sharp and caution should be used when handling, store safely in the    

  storage case when not in use. 

 

8

  

DO NOT

 use the gauge if damaged.

 

9

   Maintain the gauge in good and clean condition for best and safest performance.

 

9

   Keep the work area clean, uncluttered and ensure there is adequate lighting. 

 

9

   Maintain correct balance and footing. ensure the floor is not slippery and wear non-slip shoes.

 

9

   Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery. Contain or tie back long hair.

 

9

   Keep children and unauthorised persons away from the work area.

2.  INTRODUCTION

 

  Precision ground base with 6 button electronic gauge. Includes fine adjustment control carriage for accurate use. 6-digit lCd read-out  

 

  displays in metric or imperial. Supplied with scriber foot and clamp. Powered by CR2032 battery (included) and supplied with storage  

 

 case.

3.  SpECIfICATION

Measuring range

: .................................... 0 - 300mm / 0 - 12in

Accuracy

: ...................................................0.03mm / 0.0012in

Resolution

: .................................................0.01mm / 0.0001in

Repeatability

: .............................................0.01mm / 0.0005in

Power switch

mm / inch selection

Relative / Absolute

Zero setting button

+ preset button

- preset button

A Scale

B Beam

C  Fine adjustment 

d  lCd display

e  Fastening Screw

F  Battery lid

G Base

H Scribe

operating temperature: ............................................... 0 - 40ºC

Storage temperature: ..............................................  -20 - 70ºC

Max. relative humidity: ......................................................  80%

4.  OpERATION

4.1.    

TO fIT SCRIbER

4.1.1.   

Place the clamp upon the arm extending from the slider.

4.1.2.   

Slot the scriber into the clamp and tighten.

4.2.   

 

Turn the gauge on by pressing the power button (Fig 1.1).

4.3.    

Select the desired units of measurement (inch / mm) using the selection button (Fig 1.2).

4.4.    

To set the gauge to absolute zero at any point, press the Zero setting button (Fig 1.4). 

4.5.    

To set the origin to a value other than zero, use the +/- preset buttons (Fig 1.5.6).

4.5.1.  

 

To increase the value of the origin, press the zero setting button and +preset button  

 

 

simultaneously. The word “set” will flash in the display. To increase the value by   

 

   fig.1

1

6

5

2

4

A

B

C

d
e

F
G

H

3

   fig.2

Arm

Clamp

Scriber

  

AK9636d.V2 Issue 2 (HF) 05/10/18

Original Language Version

© Jack Sealey limited