Original Language Version
© Jack Sealey Limited
Sealey Group, kempson Way, Suffolk business Park, bury St Edmunds, Suffolk. IP32 7aR
01284 757500
01284 703534
www.sealey.co.uk
ENvIRONMENt PROtECtION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note
: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important
: No Liability is accepted for incorrect use of this product.
Warranty
: Guarantee is 12 months from purchase date, proof of which is required for any claim.
AK624 | Issue: 1 09/10/18
°C
%
Min Torque:
27
Max torque:
204
Min
Max
20%
40.8
39.17
42.43
60% 122.4
117.50
127.30
100%
204
195.84
212.16
Min Torque:
Max torque:
Min
Max
20%
0
0.00
0.00
60%
0
0.00
0.00
100%
0
0.00
0.00
Tool Model Number
Tool Serial Number
Tested by (print name)
Date of test
4
Notes:
© Jack Sealey Limited
Issue 4P 30/05/18
Declara on of Conformance
(in accordance with BS EN ISO 6789-1:2017)
1
Measurement error
2
Average
Humidity
Test units: (Nm, lb/ etc)
30
59
TORQUE TESTER
4266
2018/6/20
±1%
0.031kgf.m
Test machine type/name
Test
%
Test
Load
Test machine serial No.
Test machine calibra on date
Test
Load
Tolerance ± 4 % of Test Load
Test
%
1
2
4
5
Tolerance ± 4 % of Test Load
2
Completed test reading
3
3
4
Average
John Li
3
3
The observed values fall within the maximum permissible devia on (tolerance). For tools with a
flexible head, the result is valid only if the measuring axis is perpendicular to the axis of the tool.
TORQUE TOOL
CAL IBRATION CERTIFICATE
4
This Sealey Declara on of Conformance is issued at the me of manufacture. Its' validity is open
ended un the torque tool is used for the first me. The default re-calibra on period of 12 months (or
5,000 cycles, whichever occurs first) starts a er first use of the torque tool (BS EN ISO 6789-1:2017,
clause 5.3 refers).
AK624
1
Tes ng is in compliance with Interna onal Standard procedures, with test equipment calibrated by a
laboratory traceable to Interna onal Standards.
1
2
Nm
Measurement uncertainty
Ambient temperature
2
Measurement error shall be less than ¼ of the maximum permissible rela ve devia on of the torque
tool.
1
Completed test reading
3
Clockwise
(This part 2 to be completed only where applicable)
5