background image

Gravity & suction feed/air discharGe 
oil drainer

model no:   

aK459dX.v2

thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these instructions, 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  safety

 

‰

   WarninG

: ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this  

 

 equipment.

 

9

   Familiarise yourself with the application and limitations of the oil drainer, as well as the potential hazards.

 

‰

   WarninG

: disconnect the drainer from the air supply before changing accessories, servicing or performing any maintenance.

 

9

   maintain  the  drainer in good condition (use an authorised service agent).

 

9

   Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

 

9

   Keep the work area clean, uncluttered and ensure there is adequate lighting.

 

9

   Keep the drainer clean for best and safest performance.

 

9

   maintain correct balance and footing. ensure the floor is not slippery and wear non-slip shoes.

 

9

   Keep children and unauthorised persons away from the working area.

 

‰

   WarninG

: ensure correct air pressure is maintained and not exceeded.

 

9

   Keep air hose away from heat, oil and sharp edges. Check air hose for wear before each use, and ensure that all connections are    

 secure.

 

8

   do not 

use the drainer for any purpose other than that for which it is designed.

 

8

   do not

 operate the drainer if any parts are damaged or missing as this may cause failure and/or personal injury.

 

8

   do not

 stand on the drainer.

 

8

   do not

 adjust or tamper with the safety valve.

 

8

   do not

 move the drainer by the hose, or pull the hose sharply from the air supply.

 

8

   do not

 place attachments close to your face and 

do not 

point hose at other persons or animals.

 

8

   do not

 allow untrained persons to operate the drainer.

 

8

   do  not

 operate the drainer when you are tired, under the influence of alcohol, drugs or intoxicating medication.

 

8

   do not

 leave the drainer operating unattended.

 

8

   do not

 direct air from the air hose at yourself or others.

 

9

   When not in use disconnect from the air supply, vent reservoir and store in a safe, dry, childproof area.

 

9

   dispose of waste oil in accordance with local authority regulations.

 

‰

   WarninG:  do not

 pollute the environment by allowing uncontrolled discharge of waste oil.

2. 

introduction

 

Steel fabricated 90ltr reservoir and telescopic steel drain pan fitted with filter grid. Venturi suction pump powers oil dipstick probes    

 

and includes a set of quick release probes. Gravity or suction feed reservoir with air discharge. Fitted with oil level indicator tube. 

 

Supplied with mercedes adaptor.

3. 

specification

Model no: ........................................................aK459dX.v2

Capacity: ........................................................................90ltr

minimum Height to Pan: .......................................... 1300mm

maximum Height to Pan: ......................................... 1750mm

Gravity Feed: .................................................................. Yes

Suction Feed: .................................................................. Yes

Gravity discharge: ........................................................... no

Air discharge: ................................................................. Yes

Pump discharge ............................................................... no

4.  air supply

4.1. 

 

Recommended hook up is shown in fig.1. 

4.2. 

 

Ensure the air valve is in the “Off” position before connecting to the air supply.

4.3.    

You will require an air pressure of 7 bar.

 

‰

 WarninG: 

ensure the air supply is clean and does not exceed pressures 

 

specified in these Instructions. Too high an air pressure and/or unclean air will

 

shorten the drainer life due to excessive wear, and may be dangerous.

AK459dX.V2  Issue 2  19/11/18

Original Language Version

© Jack Sealey limited

Refer to 

instruction

manual

Wear protective 

gloves

Wear eye 

protection

Wear protective 

clothing

fig.1

Содержание AK459DX.V2

Страница 1: ...ny parts are damaged or missing as this may cause failure and or personal injury 8 8 DO NOT stand on the drainer 8 8 DO NOT adjust or tamper with the safety valve 8 8 DO NOT move the drainer by the hose or pull the hose sharply from the air supply 8 8 DO NOT place attachments close to your face and DO NOT point hose at other persons or animals 8 8 DO NOT allow untrained persons to operate the drai...

Страница 2: ... SUCTION 6 2 1 Open valve fig 6 4 completely by turning it counter clockwise Close the suction valve fig 6 1 close air valve fig 6 5 and close the drain valves fig 6 2 and fig 6 6 6 2 2 Connect the compressed air at 7bar 100psi to quick coupling fig 5 2 open the ball valve fig 5 1 and valve fig 5 4 Air will flow out of the muffler fig 5 3 6 2 3 When the arrow of the vacuum gauge approaches the red...

Страница 3: ...t from air supply and vent any pressure remaining in the reservoir by opening drainpan valve fig 8 5 and or air valve fig 7 2 NOTE The unit storage tank has been fitted with a safety valve factory calibrated to 0 5Bar 7 25psi NOTE Some cars have a built in suction probe In this case check vehicle manufacturer s data to determine the correct suction probe to be used fig 9 Original Language Version ...

Страница 4: ...he product becomes completely unserviceable and requires disposal drain any fluids if applicable into approved containers and dispose of the product and fluids according to local regulations Note It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice Important No Liability is accepted for incorrect use...

Отзывы: