3.1

 

Trolley Assembly (fig.1)

3.1.1  Attach the two castor wheels (10) to the base plate (16) using washers (9)  

 

and nuts (8).

3.1.2  Turn the base plate upside down and attach the axles (14) to the base plate  

 

using hex bolts (15) and then slide the wheels (13) onto the axles and    

 

secure using washers (12) and hex bolts (11). Turn the base plate over so  

 

that it is now supported on its wheels.

3.1.3  Slide the two pump support brackets (4) onto the handle (3) and attach    

 

them using hex grub screws (5).

3.1.4  Slide the accessory support (7) onto the other side of the handle and attach  

 

using hex grub screw (5), insert stopper (6) into the top of the accessory   

 

support.

3.1.5  Slide the handle assembly into the base plate until it bottoms out on the    

 

stops and secure with two hex grub screws (17).

3.1.6

 

Slide the drum holder support into the handle and secure using knob (1).

3.1.7  Adjust the pump support brackets, so that they fully support the pump 

 

assembly and check all nuts are tight.

3.2 

Pump and Air Regulator/Lubricator Assembly

3.2.1  Apply a small amount of liquid thread sealant onto the threads of the air    

 

inlet of the pump and attach the air regulator/lubricator (fig.2).

❐ 

WARNING!

 

DO NOT

 allow thread sealant to enter the pump.

3.2.2  Attach the outlet pipe to the male outlet thread on the pump and attach the  

 

male threaded end of the pipe to the Digital Hose End Meter.

3.2.3  Attach the nozzle valve pipe assembly to the outlet of the Digital Hose End  

 

Meter.

❐ 

WARNING!

 

DO NOT

 overtighten the swivel connections.

3.2.4  Slide the locking nut, locking ring and the barrel nut onto the pick up probe  

 

of the pump (fig.3), screw the locking nut onto the barrel nut to lock the 

 

assembly to the pick up probe.

3.2.5  Insert the pump assembly into the support brackets on the trolley and hang  

 

the meter onto the accesssory support bracket.

fig.1

fig.2

A

BC

fig.3

Locking

 

Nut

Lock Ring

Barrel Nut

  3.  AssemBly

Содержание AK4561D

Страница 1: ... a slope or traverse slopes which may cause the unit to topple The unit must be stored on a level surface Keep the pump clean and store in a safe dry childproof location WARNING DO NOT allow uncontrolled discharge of fluids thus polluting the environment All liquids must be disposed of according to local authority regulations Instructions for Oil dispensing system air operated Model No AK4561D 1 S...

Страница 2: ... secure using knob 1 3 1 7 Adjust the pump support brackets so that they fully support the pump assembly and check all nuts are tight 3 2 Pump and Air Regulator Lubricator Assembly 3 2 1 Apply a small amount of liquid thread sealant onto the threads of the air inlet of the pump and attach the air regulator lubricator fig 2 WARNING DO NOT allow thread sealant to enter the pump 3 2 2 Attach the outl...

Страница 3: ...g 5 1 and fig 5 2 simultaneously to display the current correction factor Qty Dispensed Qty Indicated x Current Correction Factor New Correction Factor 4 6 Programming the Correction Factor 4 6 1 Remove the rubber protective cover from the meter and unscrew the four phillips screws fig 6 holding the digital meter remove from the gun 4 6 2 Press button 2 on the rear of the meter fig 7 2 for 1 sec t...

Страница 4: ...pensing System Air Operated Model AK4561D 2002 95 EC RoHS Directive 2002 96 EEC WEEE Directive 14th November 2008 Signed by Steve Buckle AK4561D Issue No 1 14 11 08 fig 9 5 1 Changing the Digital Meter Battery 5 1 1 Remove the rubber protective cover from the meter 5 1 2 Remove the screw and cover from the side of the meter 5 1 3 Remove and replace battery fig 8 5 1 4 Replace cover and secure with...