 7.  MAINTENANCE

6.5.4

  Press the RESET Key for 2 Seconds

 

We now go on to Direct change of the 

 

calibration factor: the word “Direct” 

 

appears together with the currently 

 

Used calibration factor. In the bottom 

 

left part of the display, an arrow appears 

 

(upwards or downwards) defining the direction (increase or  

 

decrease) of change of the displayed value when subsequent  

 

operations 5.5.5 or 5.5.6 are performed.

6.5.5

  Press the RESET Key

 

Arrow direction changes. the operation 

 

can be repeated to alternate the 

 

direction of the arrow.

6.5.6

  Press the CAL Key

 

the indicated value changes in the 

 

direction indicated by the arrow by one 

 

unit for each press of the cAl key. 

 

By continuous holding of the cAl key 

 

the first 5 units will change slowly and 

 

will then change quickly. If the desired value is exceeded,  

 

repeat the operations from point (5.4.5).

6.5.7 

   Press the RESET Key for 2 Seconds

 

ADB02 is informed that the calibration 

 

procedure is finished. Before performing 

 

this operation, make sure the indicated

 

value is that required.

6.5.8

 

At the end of the calculation, the new 

 

UsER K FActoR is shown for a few 

 

seconds, after which the restart cycle is

 

repeated to finally achieve standby.

ATTENTION! 

From now on, the indicated factor will become  

 

the calibration factor used by the meter and will continue to  

 

remain such even after a battery change.

6.5.9

 

the ADB02 stores the new work calibration 

 

factor and is ready to begin dispensing, 

 

using the UsER K FActoR that has just

 

been calculated.

6.6 

Unit Configuration

 

some models of meter feature a menu with which the user  

 

can select the main measurement unit, Quarts (Qts), Pints  

 

(Pts), Litres (L), Gallons (Gal).

 

The combination of the unit of measurement of the Partial  

 

register and that of the totals is predefined according to the  

 

following table:

 

 

 

To choose between the 4 available combinations:

6.6.1  Wait for ADB02 to go to standby.

6.6.2  Press the CAL and RESET keys together. Keep these  

 

pressed until the word “UnIt” appears on the screen together  

 

with the unit of measurement set at that time (in this example  

 

litres / litres).

 

6.6.3  Press the RESET key to select the desired combination of  

 

unit of measurement, amongst those shown below.

6.6.4  Save the new combination by pressing the CAL key at length.  

 

ADB02 will pass through the start cycle and will then be ready  

 

to dispense in the set units.

WARNING!

 

the Resettable total and total registers will be  

 

automatically changed to the new unit of measurement. no  

ADB06

Issue no: 1 - 19/06/13

Combination 

No

Unit of Measure of 

the Partial Register

Unit of Measure of 

the Totals Register

1

litres (l)

litres (l)

2

Gallons (Gal)

Gallons (Gal)

3

Quarts (Qts)

Gallons (Gal)

4

Pints (Pts)

Gallons (Gal)

 

ADB06 has been designed to require a minimum amount  

 

of maintenance.

7.1  

Battery Replacement

 

ADB06 is supplied with 2 x 1.5 V. alkaline AAA batteries and

 

features two low-battery alarm levels.

 

7.1.1  When the battery charge falls below the 

 

first level on the lcD, the fixed battery 

 

symbol appears. In this condition, ADB06 

 

continues to operate correctly, but the 

 

fixed icon warns the user that it is 

 

ADVIsABlE to change the batteries.

7.1.2  If ADB06 operation continues without 

 

changing the batteries, the second 

 

battery alarm level will be reached 

 

which will prevent operation. In this 

 

condition the battery icon starts to flash and is the only one  

 

to remain visible on the lcD.

WARNING! Discard the old batteries in accordance with  

 

local authority regulations.

 

7.1.3  Press RESET to update all the totals.

7.1.4   Fold back the outer rubber cover and remove the screw  

 

holding the right hand battery box cover in place (fig.3).  

 

Remove the cover to reveal the batteries (fig.4).

7.1.5  Remove the old batteries (fig.4).

7.1.6  Place the new batteries in the same position as the old ones.

7.1.7  secure the battery cover and pull the outer rubber cover  

 

back over the meter.

7.1.8  the unit will switch on automatically and normal operation  

 

can be resumed. It will display the same Reset total,  

 

the same Total and the same Partial indicated before the  

 

batteries were changed. After changing the batteries, the  

 

meter does not need calibrating again.

    Original Language Version 

© Jack sealey limited

fig.4

fig.3

Содержание Adblue ADB06

Страница 1: ...ORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED FAILURE TO DO SO MAY CAUSE DAMAGE OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE USE Thank you for purchasing a Sealey product Manufactured to a high standard this product will give you years of trouble free performance if these instructions are carefully followed and the product is cor...

Страница 2: ...3 Indication of calibration mode 4 Totals register 6 figures with moving comma FROM 0 1 to 999999 that can indicate two types of Total 4 1 General Total that cannot be reset TOTAL 4 2 Resettable total Reset TOTAL 5 Indication of total multiplication factor x10 x100 6 Indication of type of total TOTAL Reset TOTAL 7 Indication of unit of measurement of Totals L Litres Gal Gallons 8 Indication of Flo...

Страница 3: ...nd hold down the CAL button Why enter the calibration phases To display the currently used calibration factor Return to factory k factor after a previous calibration with user k factor Change the calibration factor using one of the two previously indicated procedures In calibration mode the partial and total dispensed quantities indicated on the display screen take on different meanings according ...

Страница 4: ...Real value ADB02 calculates the new USER K FACTOR This calculation could require a few seconds depending on the correction to be made During this operation the arrow disappears but the CAL indication remains If this operation is performed after operation 5 4 5 without changing the indicated value the USER K FACTOR would be the same as the FACTORY K FACTOR thus it is ignored 6 4 9 At the end of the...

Страница 5: ...ogether with the unit of measurement set at that time in this example Litres Litres 6 6 3 Press the RESET key to select the desired combination of unit of measurement amongst those shown below 6 6 4 Save the new combination by pressing the CAL key at length ADB02 will pass through the start cycle and will then be ready to dispense in the set units q WARNING The Resettable Total and Total registers...

Страница 6: ...gue on 01284 757525 and leave your full name and address including your postcode Under the Waste Batteries and Accumulators Regulations 2009 Jack Sealey Ltd are required to inform potential purchasers of products containing batteries as defined within these regulations that they are registered with Valpak s registered compliance scheme Jack Sealey Ltd s Batteries Producer Registration Number BPRN ...

Отзывы: