7.  TROUBLESHOOTING

Problem

Possible cause

Remedy

Jack will not lift the load

Overloaded

Oil level low

Release valve not correctly closed

Air in system

Piston rod not functioning

Packing worn or defective

Use jack with correct capacity

Top up oil level

Check and close release valve

Open release valve and air vent (if fitted) 

and pump the handle 15 to 20 times. Close 

valve and re-try

Clean and replace oil

Replace packing

Jack does not lift high enough or 

feels spongy

Oil level too high or low

Worn seals

Air in system

Release valve not closed

Fill or remove excess oil

Return jack to local service agent

Open release valve and air vent (if fitted) 

and pump the handle 15 to 20 times. Close 

valve and re-try

Check and close release valve

Jack lifts poorly

Pump packing or valves 

malfunctioning

Oil is dirty

Air in the system

Replace packing and/or clean valves

Replace packing and/or clean valves

Replace oil

Open release valve and air vent (if fitted) 

and pump the handle 15 to 20 times. Close 

valve and re-try Replace oil

Open release valve and air vent (if fitted) 

and pump the handle 15 to 20 times. Close 

valve and re-try

Jack lifts but will not hold the 

load

Release valve partially open

Dirt on valve seats

Air in system

Faulty seals

Packing worn or defective

Check and close release valve

Lower jack, close release valve. Place foot 

on front wheel and pull up lifting arm to it’s 

full height by hand. 

Open the release valve to lower arm

Open release valve and air vent (if fitted) 

and pump the handle 15 to 20 times. Close 

valve and re-try

Replace packing or contact local service 

agent

Replace packing

Jack does not lower completely

Unit requires lubrication

Piston rod bent or damaged

Jack frame/link system distorted 

due to overloading/poor 

positioning

Air in system

Release valve partially open

Jack spring damaged

Oil all external parts

Replace rod or contact local service agent

Replace parts or contact local service 

agent

O

pen release valve and air vent (if fitted) 

and pump the handle 15 to 20 times. Close 

valve and retry

Check and fully open release valve

Replace spring or contact local service 

agent

Jack does not lower at all

Release valve still closed

Check and fully open release valve

Note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call 

our technical team on [email protected] or 01284 757505.

Important

: No Liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.

3290CX.V2     Issue:2 (3)     08/02/21

Отзывы: