© Sealevel Systems, Inc.
- 8 -
ULTRA 530.LPCI User Manual
Baud Rates and Divisors for the ‘Div1’ mode
The following table shows some common data rates and the rates you should
choose to match them if using the adapter in the ‘Div1’ mode.
For this Data Rate
Choose this Data Rate
1200 bps
150 bps
2400 bps
300 bps
4800 bps
600 bps
9600 bps
1200 bps
19.2K bps
2400 bps
57.6 K bps
7200 bps
115.2 K bps
14.4 K bps
230.4K bps
28.8 K bps
460.8K bps
57.6K bps
921.6K bps
115.2K bps
If your communications package allows the use of Baud rate divisors, choose
the appropriate divisor from the following table:
For this Data Rate
Choose this Divisor
1200 bps
768
2400 bps
384
4800 bps
192
9600 bps
96
19.2K bps
48
38.4K bps
24
57.6K bps
16
115.2K bps
4
230.4K bps
3
460.8K bps
2
921.6K bps
1
Isochronous Clocking Jumpers
The Oxford Semiconductor 16C950 allows for the reception of both transmit and
receive clocks for isochronous communications (for a discussion on isochronous
clocking refer to the Technical Description section). The header that provides the
selection of either a modem control signal or the clock option is header E3.
Figure 12 - Header E3, Clocking and Modem control signal selection