SeaLevel SIO-104+2 Series Скачать руководство пользователя страница 8

 

© Sealevel Systems, Inc.  3502 Manual   |   SL9116    9/2022 

Installation 

Software Installation 

Windows Installation 

 

         Do not install the Adapter in the machine until the software has been fully installed

 

Only users running Windows 7 or newer should utilize these instructions for accessing and 
installing the appropriate driver via Sealevel’s website. If you are utilizing an operating system 
prior to Windows 7, please contact Sealevel by calling 864.843.4343 or emailing 

[email protected]

  to receive access to the proper driver download and installation 

instructions.  

 

1.

 

Begin by locating, selecting, and installing the correct software from the 

Sealevel 

software driver database

. 

2.

 

Select the Part Number (3502) for your device from the listing. 

3.

 

Click the ‘Download Now’ button for SeaCOM for Windows. 

4.

 

The setup file will automatically detect the operating environment and install the 
proper components.  

To confirm that the SeaCOM driver has been successfully installed, click on the ‘Start’ button, and then 
select ‘All Programs’. You should see the ‘SeaCOM’ program folder listed. 

You are now ready to proceed with connecting the 3502 to your system. Refer to the Hardware 
Installation section for details.

 

Other Operating Systems 

Refer to the appropriate section of the Serial Utilities Software. 

 

 

 

Содержание SIO-104+2 Series

Страница 1: ...1 Sealevel Systems Inc 3502 Manual SL9116 9 2022 SIO 104 2 User Manual 3502...

Страница 2: ...YOU GET STARTED 4 CARD SETUP 5 INSTALLATION 8 TECHNICAL DESCRIPTION 10 SPECIFICATIONS 12 APPENDIX A TROUBLESHOOTING 13 APPENDIX B HOW TO GET ASSISTANCE 14 APPENDIX C ELECTRICAL INTERFACE 15 APPENDIX D...

Страница 3: ...for your PC 104 application The SIO 104 2 when configured in the RS 422 485 mode provides an interface capable of long length high speed communications or when configured in the RS 232 mode provides a...

Страница 4: ...roduct to fail Note The lowest level of importance used to provide background information additional tips or other non critical facts that will not affect the use of the product Optional Accessories C...

Страница 5: ...required please contact Sealevel Systems Technical Support about a custom PAL option 1 2 3 3F8 On On On 2F8 On On Off 3E8 On Off On 2E8 On Off Off 2A0 Off On On 300 Off On Off 328 Off Off On Disabled...

Страница 6: ...This ability is especially useful in Windows Windows NT and OS 2 environments where the lower level I O control is abstracted from the application program This ability means that the user can effecti...

Страница 7: ...le for each position s operation Name Function PD Adds or removes the 1K ohm pull down resistor in the RS 422 RS 485 receiver circuit Receive data only PU Adds or removes the 1K ohm pull up resistor i...

Страница 8: ...allation instructions 1 Begin by locating selecting and installing the correct software from the Sealevel software driver database 2 Select the Part Number 3502 for your device from the listing 3 Clic...

Страница 9: ...sealevel com Physical Installation Extreme care should be taken when installing the adapter to avoid causing damage to the connectors After the adapter is installed connect your I O cables Please not...

Страница 10: ...interface is fully compatible with the DOS operating system all popular modem software network operating systems software and mouse drivers Features Selectable interrupts IRQs 3 4 5 7 9 10 11 12 15 Mu...

Страница 11: ...Send Negative 4 7 Output RX Receive Data Positive 1 1 Input RX Receive Data Negative 3 2 Input CTS Clear to Send Positive 8 9 Input CTS Clear to Send Negative 6 8 Input Please terminate any control si...

Страница 12: ...re Range 0 to 70 C 32 to 158 F 50 to 105 C 58 to 221 F Humidity Range 10 to 90 R H Non Condensing 10 to 90 R H Non Condensing Power Consumption Supply line 5 VDC Rating 220 mA Mean Time Between Failur...

Страница 13: ...4 Make sure the Sealevel Systems adapter is securely installed 5 If you are utilizing an operating system prior to Windows 7 please contact Sealevel by calling 864 843 4343 or emailing support sealev...

Страница 14: ...eb site Please refer to this to answer many common questions This section can be found at http www sealevel com faq asp 4 Sealevel Systems maintains a web page on the Internet Our home page address is...

Страница 15: ...n a differential interface logic levels are defined by the difference in voltage between a pair of outputs or inputs In contrast a single ended interface for example RS 232 defines the logic levels as...

Страница 16: ...e character is defined by the transmission of a pre defined number of stop bits usually 1 1 5 or 2 An extra bit used for error detection is often appended before the stop bits Figure 3 Asynchronous Co...

Страница 17: ...cing the form factor to 3 550 by 3 775 inches Eliminating the need for backplanes or card cages through its self stacking bus Minimizing component count and power consumption typically 1 2 Watts per m...

Страница 18: ...18 Sealevel Systems Inc 3502 Manual SL9116 9 2022 Appendix F Silk Screen...

Страница 19: ...y Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase Customer agrees to ensure the Product or assume the risk of loss or damage in transit to prepay...

Отзывы: