SeaLevel R23008-01 Скачать руководство пользователя страница 20

                                                                                                                               

               

                                                                             

 

 

20 

 
         © Sealevel Systems, Inc. 

RELIO R2 SYNC Manual   |  SL9255  10/2021 

 

CMOS Battery 

The R2 SYNC includes a 3V DC type CR2032 battery that supplies the RTC and CMOS memory of the COM 
Express CPU module.  

Danger of explosion if battery is incorrectly replaced

 

 Replace only with the same or equivalent type 

recommended 

by the manufacturer.  Dispose of used batteries according to the manufacturer’s 

instructions.  

 

 

To fulfill the requirements of EN 60950, the R2 SYNC incorporates two current-limiting devices (resistor and 
diode) in the battery power supply path. 

System Description 

The following I/O connectors use industry standard pin outs for maximum compatibility. 

 

 

Front Panel I/O Connectors 

 

 

Содержание R23008-01

Страница 1: ...1 Sealevel Systems Inc RELIO R2 SYNC Manual SL9255 10 2021 Relio R2 SYNC User Manual RELIO R2 SYNC...

Страница 2: ...CTURING 10 SYSTEM OPERATION 11 POWER BUTTON 11 POWER STATES 11 SYNCHRONOUS SERIAL COMMUNICATION PORTS 11 INTERNAL BAUD RATE GENERATOR 11 CONTROL AND STATUS REGISTERS DEFINITION 12 INTERFACE SELECTION...

Страница 3: ...m solutions in the fastest time possible Common I O features include serial analog and digital I O Sealevel s extensive library of proven I O circuits can be included as required to meet the specific...

Страница 4: ...control signals implemented o Compatible with Sealevel 5402 and 5402e Synchronous cards 1 Display Port Compatible Video Output 2 Gigabit Ethernet Ports 2 USB 2 0 Ports 64GB mSATA Solid State Drive Pow...

Страница 5: ...er Supply Desktop 90 264VAC 47 63Hz 21VDC regulated 3000mA output with a KPPX 4P connector Advisory Conventions Warning The highest level of importance used to stress a condition where damage could re...

Страница 6: ...he CA104 is a standard DB25F to DB25M serial extension cable Extend a DB25 cable or locate a piece of hardware where it is needed with this six foot 72 inch cable The connectors are pinned one to one...

Страница 7: ...30 Twisted Pair Serial Cable 72 inch Length Item CA174 DB25 Female to DB25 Male Twisted Pair Serial Cable 72 inch Length Twisted Pairs provide increased data integrity in high speed serial application...

Страница 8: ...with steady state CPU usage greater than 50 some additional cooling must be used to ensure safe operation of the electronics The R2 SYNC computer system is a fan less solid state computer that relies...

Страница 9: ...output to the R2 SYNC system Typical power consumption varies depending on COM Express Module memory capacity OS software activity and peripheral devices AC current draw will never exceed 1 4 A All n...

Страница 10: ...l Name 1 Positive DC Power 2 Negative DC Power GND 3 Negative DC Power GND 4 Positive DC Power Manufacturing All Sealevel Systems printed circuit boards are built to UL 94V0 rating and are 100 electri...

Страница 11: ...standby state by holding the Power Button for 3 seconds The system can also be awoken from S3 or S4 with a USB input device such as a HID compliant keyboard or mouse To be awoken from a standby state...

Страница 12: ...D2 SD1 SD0 15 RD SD15 SD14 SD13 SD12 SD11 SD10 SD9 SD8 Field Description IRQST SCC interrupt status 1 No interrupt pending on ESCC 0 Interrupt pending on ESCC DSRA DSRA 1 DSRA not active 0 DSRA active...

Страница 13: ...are high impedance 1 0 0 0 1 not supported 2 0 0 1 0 RS 232 3 0 0 1 1 not supported 4 0 1 0 0 RS 485T with 120 termination 5 0 1 0 1 RS 485 without termination 6 7 8 9 0 1 1 0 not supported A 1 0 1 0...

Страница 14: ...RTS 19 6 56 31 81 DTR 20 7 57 32 82 DTR 23 8 58 33 83 TSET 24 9 59 34 84 TSET 11 10 60 35 85 RXD 3 11 61 36 86 RXD 16 12 62 37 87 CTS 5 13 63 38 88 CTS 13 14 64 39 89 DSR 6 15 65 40 90 DSR 22 16 66 4...

Страница 15: ...Data Output 3 RD Receive Data Input 4 RTS Request To Send Output 5 CTS Clear To Send Input 6 DSR Data Set Ready Input 7 GND Ground 8 DCD Data Carrier Detect Input 15 TXC Transmit Clock Input 17 RXC R...

Страница 16: ...gative Output 3 RDA RX Receive Negative Input 7 GND Ground 9 RXCB RXC Receive Clock Positive Input 11 TSETB TSET Transmit Signal Element Timing Output 12 TXCB TXC Transmit Clock Positive Input 14 TDB...

Страница 17: ...D Data Carrier Detect Positive Input 11 TSETB TSET Transmit Signal Element Timing Output 12 TXCB TXC Transmit Clock Positive Input 13 CTSB CTS Clear To Send Positive Input 14 TDB TX Transmit Positive...

Страница 18: ...Negative Input 9 RXCB RXC Receive Clock Positive Input 11 TSETB TSET Transmit Signal Element Timing Output 12 TXCB TXC Transmit Clock Positive Input 13 CTSB CTS Clear To Send Positive Input 14 TDB TX...

Страница 19: ...RXCB RXC Receive Clock Positive X Input 11 TSETB TSET Transmit Signal Element Timing W Output 12 TXCB TXC Transmit Clock Positive AA Input 14 TDB TX Transmit Positive S Output 15 TXCA TXC Transmit Cl...

Страница 20: ...replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions To fulfill the requirements of EN 60950 th...

Страница 21: ...21 Sealevel Systems Inc RELIO R2 SYNC Manual SL9255 10 2021 Rear Panel I O Connectors...

Страница 22: ...22 Sealevel Systems Inc RELIO R2 SYNC Manual SL9255 10 2021 Mechanical Drawings Top View...

Страница 23: ...Continued Bottom View The mounting brackets included with the computer allow options for two methods Flush Mounting If the computer is to be mounted to a thermally conductive surface it is recommended...

Страница 24: ...24 Sealevel Systems Inc RELIO R2 SYNC Manual SL9255 10 2021 Mechanical Drawings Continued Front View Rear View...

Страница 25: ...Raised Mounting If the computer is to be mounted to a thermally insulating surface such as a plastic or wood surface it is recommended to use the method that raises the computer 0 5 off the surface T...

Страница 26: ...2021 Mechanical Drawings Continued Rear view Side view If no airflow is present in the application environment orienting the computer so the heat sink fins run in the Z direction vertically up and dow...

Страница 27: ...wise unavailable or if desired the current versions of Sealevel software packages can be obtained from the Sealevel website see following instructions If you already have the Sealevel software proceed...

Страница 28: ...t and enter the BIOS 3 Press the F9 key to load optimal defaults then press enter to validate the change 4 Press the following key pattern Right arrow Enter Down arrow 9 times Enter Up arrow Enter F10...

Страница 29: ...ctrostatically sensitive components in protective packaging or on anti static mats Grounding Methods The following measures help to avoid electrostatic damages to the device Cover workstations with ap...

Страница 30: ...DTE and Data Circuit Terminating Equipment DCE RS 485 RS 485 is backwardly compatible with RS 422 however it is optimized for party line or multi drop applications The output of the RS 485 driver is c...

Страница 31: ...d by the transmission of a pre defined number of stop bits usually 1 1 5 or 2 An extra bit used for error detection is often appended before the stop bits The diagram below demonstrates asynchronous c...

Страница 32: ...m neglect abuse accidents or acts of nature are not covered under this warranty Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase Customer agrees t...

Отзывы: