SeaLevel PIO-96.PCI Скачать руководство пользователя страница 25

 

Appendix D - Compliance Notices 

Sealevel Systems 

PIO-96.PCI 

Page 

22

 

Appendix D - Compliance Notices 

Federal Communications Commission Statement 

FCC - This equipment has been tested and found to comply with the limits for 
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are 
designed to provide reasonable protection against harmful interference when 
the equipment is operated in a commercial environment. This equipment 
generates, uses, and can radiate radio frequency energy and, if not installed and 
used in accordance with the instruction manual, may cause harmful interference 
to radio communications. Operation of this equipment in a residential area is 
likely to cause harmful interference. In such case the user will be required to 
correct the interference at his own expense. 
 

EMC Directive Statement

 

Products bearing the CE Label fulfill the requirements of the 
EMC directive (89/336/EEC) and of the low-voltage directive 
(73/23/EEC) issued by the European Commission. 
 

To obey these directives, the following European standards must be met: 
 
• 

EN55022 Class A

  - “Limits and methods of measurement of radio 

interference characteristics of information technology equipment” 

 
• 

EN55024

 

-'Information technology equipment Immunity  

characteristics Limits and methods of measurement' 

 
• 

EN60950 (IEC950)

  - “Safety of information technology 

 

equipment, including electrical business equipment” 

 

Warning 

This is a Class A Product. In a domestic environment this product may 
cause radio interference in which case the user may be required to take 
adequate measures. 

 
Always use cabling provided with this product if possible. If no cable is 
provided or if an alternate cable is required, use high quality shielded cabling to 
maintain compliance with FCC/EMC directives. 
 

 

Содержание PIO-96.PCI

Страница 1: ...Part 8009 Sealevel Systems Inc 155 Technology Place P O Box 830 Liberty SC 29657 USA Phone 864 843 4343 FAX 864 843 3067 www sealevel com PIO 96 PCI USER MANUAL TM...

Страница 2: ...AMMERS INTERFACE API 8 Reading the Inputs 8 Reading the Outputs 8 Presetting an Output Port 8 Writing the Outputs 8 Interrupts 8 Port Configuration 9 Relative Addressing vs Absolute Addressing 10 Addr...

Страница 3: ...e 3 50 Pin Ribbon Cable Pin Out 7 Figure 4 Control Words Port Direction 9 Figure 5 Absolute byte Address any configuration 11 Figure 6 Relative byte Address 11 Figure 7 Absolute Bit Address Same for a...

Страница 4: ...r TB07 50 pin terminal block Installation Card Setup The PIO 96 PCI is a fully compliant PCI Plug and Play adapter All card resources i e I O address IRQ selection are auto assigned by either your sys...

Страница 5: ...slot and remove the blank metal slot cover 4 Remove the clamping portion of the bracket from the card 5 Gently insert the PIO 96 PCI into the slot Make sure that the adapter is seated properly 6 Feed...

Страница 6: ...to low level driver development Popular development environments including Visual C Visual Basic and Delphi are supported for application development SeaI O includes sample applications and a utility...

Страница 7: ...rty Software Support Third party software support for many HMI MMI and other process control software is included on the product installation CD For the most up to date information on third party soft...

Страница 8: ...ransceiver Each input is capable of sinking up to 24 mA while each output can source up to 15 mA Recommended Operating Conditions Min Max Input 0 V 5 25 V Source 15 mA Sink 24 mA Electrical Characteri...

Страница 9: ...re 2 below provides the bussed resistor and corresponding port The resistors insure that no line is floating which is not connected This provides consistent biasing on all un terminated lines Bussed C...

Страница 10: ...in ribbon cable pin out Figure 3 50 Pin Ribbon Cable Pin Out Description Pin Port A A0 47 A1 45 A2 43 A3 41 A4 39 A5 37 A6 35 A7 33 Port B B0 31 B1 29 B2 27 B3 25 B4 23 B5 21 B6 19 B7 17 Port C C0 15...

Страница 11: ...API returns the complement of value that is currently being used to drive the outputs The outputs cannot be read with relative addressing absolute addressing must be used Refer to Relative Addressing...

Страница 12: ...ault on power up The default settings are based on the settings in the control panel application when last changed and saved after re booting Control Word 0 Bank 1 A1 B1 C1 Control Word 1 Bank 2 A2 B2...

Страница 13: ...the I O address base 0 Port 1 refers to the I O address base 1 Relative addressing mode on the other hand refers to input and output ports in a logical fashion With a Port argument of 0 and an API fun...

Страница 14: ...8 R W B2 9 R W C2 10 R W A3 16 R W B3 17 R W C3 18 R W A4 24 R W B4 25 R W C4 26 R W Figure 5 Absolute byte Address any configuration Port API Port Relative Address function Port Type A1 0 R Input B1...

Страница 15: ...71 A2 7 135 A3 7 199 A4 7 8 B1 0 72 B2 0 136 B3 0 200 B4 0 9 B1 1 73 B2 1 137 B3 1 201 B4 1 10 B1 2 74 B2 2 138 B3 2 202 B4 2 11 B1 3 75 B2 3 139 B3 3 203 B4 3 12 B1 4 76 B2 4 140 B3 4 204 B4 4 13 B1...

Страница 16: ...Port Address Port A1 A2 A3 A4 B1 B2 B3 B4 C1 C2 C3 C4 Figure 8 Relative Byte Address Print and fill in for your configuration Bank 1 P2 Bank 2 P3 Bank 3 P4 Bank 4 P5 Address Port Bit Address Port Bit...

Страница 17: ...ohm pull up resistors on each port Reading the Outputs The value that is currently being used to drive the outputs will be returned Presetting an Output Port Each port has an output register associat...

Страница 18: ...ort C2 RD WR PC2D7 PC2D6 PC2D5 PC2D4 PC2D3 PC2D2 PC2D1 PC2D0 Base B Control Word Port 2 WR CW2D7 0 0 CW2D4 CW2D3 CW2D2 CW2D1 CW2D0 Base C Interrupt configuration Port 2 RD WR 0 0 0 0 0 IRQEN2 IRQC21 I...

Страница 19: ...input 1 0 input 1 1 input Control Word X 0 Hex Value Port Setup 7 6 5 4 3 2 1 0 A B C Upper C Lower 1 X X 0 0 X 0 0 80 Out Out Out Out 1 X X 0 0 X 0 1 81 Out Out In In 1 X X 0 0 X 1 0 82 Out In Out Ou...

Страница 20: ...ect see table Figure 11 Interrupt Control Interrupt mode select table IRQCn1 IRQCn0 INT Type 0 0 Low level 0 1 High level 1 0 Falling edge 1 1 Rising edge Figure 12 Interrupt Mode Select Interrupt Rea...

Страница 21: ...C 4 to 158 F Humidity Range 10 to 90 R H Non Condensing 10 to 90 R H Non Condensing Power Consumption Supply line 5 VDC Rating 1000 mA Mean Time Between Failures MTBF Greater than 150 000 hours Calcul...

Страница 22: ...stallation files in the correct locations 1 Read this manual thoroughly before attempting to install the adapter in your system 2 Use Device Manager under Windows to verify proper installation 3 Use t...

Страница 23: ...tion on its web site Please refer to this to answer many common questions This section can be found at http www sealevel com faq htm 4 Sealevel Systems maintains a Home page on the Internet Our home p...

Страница 24: ...Appendix C Silk Screen Sealevel Systems PIO 96 PCI Page 21 Appendix C Silk Screen 4 20 6 80...

Страница 25: ...ence at his own expense EMC Directive Statement Products bearing the CE Label fulfill the requirements of the EMC directive 89 336 EEC and of the low voltage directive 73 23 EEC issued by the European...

Страница 26: ...uct Sealevel Systems will not be liable for any claim made by any other related party RETURN AUTHORIZATION MUST BE OBTAINED FROM SEALEVEL SYSTEMS BEFORE RETURNED MERCHANDISE WILL BE ACCEPTED AUTHORIZA...

Отзывы: