SeaLevel MIL-188-C Скачать руководство пользователя страница 3

SECTION 3. 

OPTION SELECTION

 

 
The board contains several jumper straps for each port.  These jumper straps must be set for 
proper operation. 
 

PORT ENABLE / DISABLE 

 
Each port on the MIL-188-C / MIL-188-114 adapter

 

can be enabled or disabled with switch 

position 8 on the dip-switch.  The port is enabled with the switch "On" or "Closed" and 
disabled when "Off" or "Open".  If any port is disabled, be sure to also disable the interrupt 
request for that port by removing the IRQ jumper (see Figure 3). 
 
INTERFACE SELECTION: 
 
E1: 

Determines whether the receiver interface is MIL-188-C single-ended unbalanced, 

 

or MIL-188-114 balanced differential.  With the jumpers at E1 installed, MIL-188-C 

 

is selected, and the inverting receiver input is grounded.  With the jumpers 

removed,  or floating on one pin, the MIL-188-114 differential interface is selected. 

 
NOTE:

 

You must either install or remove all four jumpers.  Any other combination of 

 

jumpers (i.e. one on three off) is not a valid combination and can cause  erratic

 

data. 

 
E2: 

These headers select the interrupt request for each serial port.  If COM1: is 

 

selected, this jumper must be on the IRQ4 setting.  If COM2: is selected, this 

 

jumper must be on IRQ3.  

 

NOTE

Most communications software applications default COM3: to IRQ4 and  COM4:  to 

 

IRQ3. This requires the sharing of interrupts between COM1: and COM3:, and 

 

between COM2: and COM4:.  While this is the default, it is not always the preferred

 

  

setting.  Check your software configuration instructions to determine the 

 

most  

appropriate IRQ selection. 

 

 

 

FIGURE 3 

HEADER E2 ILLUSTRATION (IRQ 4 SELECTED) 

 

Any two or more ports can share a common IRQ by placing the jumpers on the same IRQ 
setting and setting the appropriate selections at E4. Consult your particular software for IRQ 
selection.  If no interrupt is desired, remove the jumper. 

 
NOTE:

  

IRQ 2 on "AT" class machines is not available .  IRQ 9 is substituted in place of 

 

IRQ 2. To select IRQ 9 place jumper on the IRQ 2 position. 

Содержание MIL-188-C

Страница 1: ...CIFICATIONS 6 WARRANTY FIGURES 1 ADDRESS SELECTION TABLE 2 DIP SWITCH ILLUSTRATION 3 HEADER E2 IRQ ILLUSTRATION 4 HEADER E4 MULTI IRQ ILLUSTRATION 5 MIL 188 114 PIN OUT 6 MIL 188 C PIN OUT 7 SILK SCRE...

Страница 2: ...DRESS BINARY SWITCH POSITION SETTING Hex A9 A0 1 2 3 4 5 6 7 280 287 1010000XXX OFF ON OFF ON ON ON ON 2A0 2A7 1010100XXX OFF ON OFF ON OFF ON ON 2E8 2EF 1011101XXX OFF ON OFF OFF OFF ON OFF 2F8 2FF 1...

Страница 3: ...all four jumpers Any other combination of jumpers i e one on three off is not a valid combination and can cause erratic data E2 These headers select the interrupt request for each serial port If COM1...

Страница 4: ...allation For Windows Users Start by choosing Install Software at the beginning of the CD Choose Asynchronous COM Port Software SeaCOM Other Operating Systems Refer to the appropriate section of the Se...

Страница 5: ...88 114 Serial Interface adapter Part 3202 provides one asynchronous serial port with the MIL 188 C Single Ended or MIL 188 114 Differential communications standard interface These interfaces are commo...

Страница 6: ...X Receive Negative 3 Input CTSB CTS Clear To Send Pos 13 Input CTSA CTS Clear To Send Neg 5 Input DSRB DSR Data Set Ready Pos 22 Input DSRA DSR Data Set Ready Neg 6 Input DCDB DCD Data Carr Detect Pos...

Страница 7: ...his period Sealevel Systems will at it s option replace or repair it at no additional charge except as set forth in the following terms This warranty does not apply to products damaged by misuse modif...

Отзывы: