SeaLevel 8012e Скачать руководство пользователя страница 20

 

20 

© Sealevel Systems, Inc.  8012e Manual   |   SL9225  12/2022 

Hardware 

 

1.

 

With the system powered down, verify the I/O adapter is seated properly into the slot. 

 

PCI Express Card Edge 

 

 

 

 

2.

 

If a slot seems unresponsive, power the system down and install the I/O adapter on a 
different slot on the motherboard. 

3.

 

Install the Sealevel Software and I/O adapter in another computer.  

BIOS  

1.

 

PCIe adapters are automatically assigned addressing and IRQs by the system BIOS based on 
availability. Ensure that available IRQs are set to PCI/PNP (this represents ‘Plug and Play’).  

2.

 

If hardware installation issues persist, remove other bus level devices from your system to 
verify if this corrects the problem. 

 

Device Manager Verification 

Once your Sealevel Software is installed, verify the I/O adapter is properly enumerated. Navigate to the 
Device Manager for verification and configuration.  

To access the Device Manager, right click on ‘My Computer’ and choose ‘Manage’.  When the Computer 
Management menu appears, choose ‘Device Manager’. 

 

 

 

Содержание 8012e

Страница 1: ...1 Sealevel Systems Inc 8012e Manual SL9225 12 2022 DIO 16 LPCIe User Manual 8012e...

Страница 2: ...8 PHYSICAL INSTALLATION 9 PROGRAMMING THE DIO 16 LPCIE 10 TECHNICAL SPECIFICATIONS 17 APPENDIX A TROUBLESHOOTING 19 SEAIO DEVICE DRIVER CONFIGURATION 25 APPENDIX B HANDLING INSTRUCTIONS 28 APPENDIX C...

Страница 3: ...tance used to stress a condition where damage could result to the product or the user could suffer serious injury Important The middle level of importance used to highlight information that might not...

Страница 4: ...cable Extend a DB44 cable or locate a piece of hardware where it is needed with this six foot 72 cable The connectors are pinned one to one so the cable is compatible with any device or cable with DB4...

Страница 5: ...efore it can be used with any DB37 board regardless of the board s port gender The TB02 KT ships with a RoHS compliant TB02 terminal block a 6 piece of slotted Snap Track and two DIN rail mounting cli...

Страница 6: ...when energized The board meets the requirements a low profile PCI Express add in card as defined by the PCI SIG in the PCI Express Card Electromechanical Specification Revision 1 1 The DIO 16 LPCIe is...

Страница 7: ...DIO 32 PCI 8004H 16 Reed Relay Outputs 16 Opto isolated Inputs 10 30V ISO 16 PCI 8006 16 Opto isolated Inputs ISO 16 PCI 8006H 16 Opto isolated Inputs 10 30V REL 32 PCI 8007 32 Reed Relay Outputs PLC...

Страница 8: ...tall the proper components Follow the information presented on the screens that follow 5 A screen may appear with text similar to The publisher cannot be determined due to the problems below Authentic...

Страница 9: ...y installed To prevent damage from improper handling please reference Appendix B ESD Handling Instructions 1 Turn off PC power Disconnect the power cord 2 Remove the PC case cover 3 Locate an availabl...

Страница 10: ...al Basic using the ActiveX control included with SeaI O is advised Samples and Utilities A variety of sample programs and utilities both executable and source code are included with SeaI O Further doc...

Страница 11: ...PC without the risk of damage due to ground loops or ground faults Each sensor input pair has a current limiting resistor that is used to limit the input current to the opto isolator The opto isolato...

Страница 12: ...the DB 44 through the optocoupler out pin 41 and back to the power source If the current flow is between 2 and 20 mA this input will be read as logic 0 All the input associated with all open switches...

Страница 13: ...4 32 5 K6 15 33 6 K7 16 34 7 K8 17 35 The above diagram is representative of how lights or other devices can be controlled by the relay outputs When relay 2 on the card is closed it will allow current...

Страница 14: ...Signal Pin s Ground 22 23 24 5 Volts 39 12 Volts 1 DB 37 Male Pin Assignment Via optional DB 44 Male to DB 37 Male 6 cable Part Number CA206 Bit Port A Pins Port C Pins 0 2 20 10 28 1 3 21 11 29 2 4 2...

Страница 15: ...ler out pin 21 and back to the power source If the current flow is between 2 and 20 milliamps this input will be read as logic 0 All the input associated with all open switches will be read as logic 1...

Страница 16: ...to flow from the power source into pin 12 of the DB 37 through the optocoupler out pin 30 and back to the power source thereby turning the light labeled 2 on The above diagram shows the common path to...

Страница 17: ...RMS Reed Relay Output Ports Contact Max Power 10W Switching Voltage Max DC Peak AC Resistive 60V Switching Current Max DC Peak AC Resistive 0 5A Life Expectancy Typical Signal Level 1V 10mA 100 milli...

Страница 18: ...clude Output Power pins 5V 12V Environmental Specifications Specification Operating Storage Temperature Range 0 C 70 C 35 C 100 C Humidity Range 10 to 90 R H Non Condensing 10 to 90 R H Non Condensing...

Страница 19: ...t verify that your Sealevel Software is properly installed This places the required installation files in the correct locations In Windows it will be located here Start All Programs SeaIO Uninstall Re...

Страница 20: ...y assigned addressing and IRQs by the system BIOS based on availability Ensure that available IRQs are set to PCI PNP this represents Plug and Play 2 If hardware installation issues persist remove oth...

Страница 21: ...ree utilities were designed to verify the functionality of your Sealevel digital I O adapters To access these utilities navigate to Start All Programs SeaIO VB Test This utility allows the setting and...

Страница 22: ...SeaIOTST This utility is a Win32 console application designed for testing all calls to the driver This utility is very useful for verifying proper SeaIO driver configuration and hardware adapter sett...

Страница 23: ...23 Sealevel Systems Inc 8012e Manual SL9225 12 2022 SeaI O Classic Hardware This is an example of a properly enumerated SeaI O digital I O adapter in Windows Device Manager...

Страница 24: ...evice category and choose Properties This will show the Properties dialog box as seen below This verifies that the SeaI O digital I O adapter 8004 is correctly enumerated To properly configure your di...

Страница 25: ...river call The default value on installation is 250 000 microseconds 250 milliseconds Setting the sampling rate below 10 000 microseconds is not recommend as this can heavily tax the host processor Wh...

Страница 26: ...te SeaIO_ReadBit SeaIO_WriteBit SeaIO_WriteAllOutputs and SeaIO_ReadAllInputs These functions should be used exclusively by new applications Positive Logic PIO cards Inputs If the input threshold volt...

Страница 27: ...ten to the port the output is 0v DIO cards Inputs If the input threshold voltage has not been met the API returns a 1 If the input threshold voltage has been met the API returns a 0 Outputs If a 0 is...

Страница 28: ...ically sensitive components in protective packaging or on anti static mats Grounding Methods The following measures help to avoid electrostatic damages to the device 5 Cover workstations with approved...

Страница 29: ...29 Sealevel Systems Inc 8012e Manual SL9225 12 2022 Appendix C Example Circuits Input Circuit Output Circuit...

Страница 30: ...30 Sealevel Systems Inc 8012e Manual SL9225 12 2022 Appendix D 8012e PCB Drawing...

Страница 31: ...r to this to answer many common questions This section can be found at http www sealevel com faq htm 4 Sealevel Systems maintains a Home page on the Internet Our home page address is www sealevel com...

Страница 32: ...aring the CE Label fulfill the requirements of the EMC directive 89 336 EEC and of the low voltage directive 73 23 EEC issued by the European Commission To obey these directives the following European...

Страница 33: ...e radio interference in which case the user may be required to take adequate measures to prevent or correct the interference Always use cabling provided with this product if possible If no cable is pr...

Страница 34: ...nty Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase Customer agrees to ensure the Product or assume the risk of loss or damage in transit to prep...

Отзывы: