SeaLevel 7106e Скачать руководство пользователя страница 20

 

 

20 

© Sealevel Systems, Inc.  7106e Manual   |   SL9268  11/2022 

In the main WinSSD window, click on the ‘BERT’ tab (Bit Error Rate test).  

Click on the ‘Start’ button.  

 

 

 

Содержание 7106e

Страница 1: ...1 Sealevel Systems Inc 7106e Manual SL9268 11 2022 Ultra 530 LPCIe User Manual 7106e...

Страница 2: ...ION 10 HARDWARE INSTALLATION 13 TECHNICAL DESCRIPTION 15 TECHNICAL SPECIFICATIONS 16 APPENDIX A TROUBLESHOOTING 17 APPENDIX B HANDLING INSTRUCTIONS 22 APPENDIX C ELECTRICAL INTERFACE 23 APPENDIX D ASY...

Страница 3: ...re control This allows the 7106e to be used with standard serial communications applications and removes the risk of bus contention and data corruption In RS 232 mode all modem control signals are imp...

Страница 4: ...ntions Warning The highest level of importance used to stress a condition where damage could result to the product or the user could suffer serious injury Important The middle level of importance used...

Страница 5: ...le with DB25 connectors The cable is fully shielded against interference and the connectors are molded to provide strain relief Dual metal thumbscrews secure the cable connections and prevent accident...

Страница 6: ...connector to 9 screw terminals to simplify field wiring of serial connections It is ideal for RS 422 and RS 485 networks yet it will work with any DB9 serial connection including RS 232 The TB05 incl...

Страница 7: ...king The 7106e operates asynchronously only and does not support isochronous clocking modes Electrical Interface Selection via Hardware Serial port on the 7106e has the ability to be used as RS 232 RS...

Страница 8: ...corresponds to a specific portion of the interface If multiple 7106e adapters are configured in a RS 485 network only the boards on each end should have switches T PU and PD ON If using the board in...

Страница 9: ...ng available only via software selection It helps minimize electromagnetic interference in applications where higher baud rates are not required RS 485 Auto Enable Delay RS 485 Auto Enable Delay is an...

Страница 10: ...s website If you are utilizing an operating system prior to Windows 7 please contact Sealevel by calling 864 843 4343 or emailing support sealevel com to receive access to the proper driver download a...

Страница 11: ...lect your product If you installed your hardware prior to loading installing the software please click on the Click here if you installed hardware before software link and follow the listed instructio...

Страница 12: ...l Panel 3 Launch the SeaCOM installer executable from the directory where it was downloaded 4 When the InstallShield Wizard window appears click the Next button to initiate the software installation 5...

Страница 13: ...ware installation process will automatically be used to configure the adapter Once the hardware installation completes you may need to restart the computer to finalize the installation process Verifyi...

Страница 14: ...console window 3 In the left pane under System Tools click Device Manager 4 In right pane near the bottom expand the Multi port serial adapters section by clicking the symbol 5 Locate the ULTRA 530 L...

Страница 15: ...control applications The 7106e provides a UART with a 256 byte TX and RX FIFOs providing programmable baud rates data format and interrupt control DB25 Male Connector Pin Assignments Pin RS 232 RS 42...

Страница 16: ...densing 10 to 90 R H Non Condensing MTBF Telcordia SR 332 prediction method Mean Time Between Failure 1 500 000 hours At 25 C ambient Manufacturing All Sealevel Systems Printed Circuit boards are buil...

Страница 17: ...If you have a loopback plug put it on the adapter connector If you do not have a loopback plug you can use female jumper wires to make the connection to verify the functionality RS 232 requires pins 2...

Страница 18: ...lder in the Start menu On the Port Information tab select the associated COM port and click the Open button This will first open the COM port From this tab the port can also be closed See image below...

Страница 19: ...19 Sealevel Systems Inc 7106e Manual SL9268 11 2022 Change your parameters to 9600 bits per second 8 data bits no parity 1 stop bit and no flow control as pictured below Click Apply and OK...

Страница 20: ...20 Sealevel Systems Inc 7106e Manual SL9268 11 2022 In the main WinSSD window click on the BERT tab Bit Error Rate test Click on the Start button...

Страница 21: ...ted data rate This verifies that the adapter is working properly You can continue testing this port with different configurations or proceed with testing other ports if necessary If these steps do not...

Страница 22: ...ically sensitive components in protective packaging or on anti static mats Grounding Methods The following measures help to avoid electrostatic damages to the device 5 Cover workstations with approved...

Страница 23: ...n a differential interface logic levels are defined by the difference in voltage between a pair of outputs or inputs In contrast a single ended interface for example RS 232 defines the logic levels as...

Страница 24: ...d The EIA Electronic Industry Association created the RS 530 specification to detail the pin out and define a full set of modem control signals that can be used for regulating flow control and line st...

Страница 25: ...he character is defined by the transmission of a pre defined number of stop bits usually 1 1 5 or 2 An extra bit used for error detection is often appended before the stop bits Figure 1 Asynchronous C...

Страница 26: ...extreme this ground current can cause equipment malfunction or even destruction Cabling Recommendations When connecting the 7106e in a RS 485 network care should be taken that both ends of the network...

Страница 27: ...27 Sealevel Systems Inc 7106e Manual SL9268 11 2022 Appendix F Mechanical Drawing...

Страница 28: ...d to correct the interference at the users expense EMC Directive Statement Products bearing the CE Label fulfill the requirements of the EMC directive 89 336 EEC and of the low voltage directive 73 23...

Страница 29: ...nty Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase Customer agrees to ensure the Product or assume the risk of loss or damage in transit to prep...

Отзывы: