SeaLevel 2433 Скачать руководство пользователя страница 24

                                                                                                                               

               

                                                                             

 

 

24 

 
         © Sealevel Systems, Inc. 

2433 Manual   |  SL9348       8/2021 

 

 

Select the ‘BERT’ tab and with the loopback connected to the port you 
wish to test, click on the ‘Start’ button. If te

sting RS-485, be sure that 

ECHO is enabled. (Pictured below) 

  

 

 

If the COM port is working properly, the green light will glow, and the 
Transmit Frames and Receive Frames will increase. The Tx and Rx Data 
Rates will show the calculated data rate. (Pictured below) 

 

 

 

You can continue testing this port with different configurations or 
proceed with testing other ports, if necessary. 

 

If these steps do not solve your problem, please call Sealevel 

Systems’ Technical Support, (864) 

843-4343. Our technical support is free and available from 8:00 AM to 5:00 PM Eastern Time 
Monday through Friday. For email support contact 

[email protected]

Содержание 2433

Страница 1: ...1 Sealevel Systems Inc 2433 Manual SL9348 8 2021 SeaLINK 4M SC User Manual 2433 ...

Страница 2: ...TION 9 HARDWARE CONFIGURATION 10 HARDWARE DESCRIPTION 14 SEALATCH USB 16 SEALATCH LOCKING USB CABLES 17 ELECTRICAL SPECIFICATIONS 18 SILK SCREEN 2433 20 TECHNICAL SPECIFICATIONS 21 APPENDIX A TROUBLESHOOTING 22 APPENDIX B HOW TO GET ASSISTANCE 25 APPENDIX C ELECTRICAL INTERFACE 26 APPENDIX D ASYNCHRONOUS COMMUNICATIONS 28 APPENDIX E SILK SCREEN 2433 29 APPENDIX F COMPLIANCE NOTICES 31 WARRANTY 32 ...

Страница 3: ...of the enclosure for easily connecting additional SeaLINK devices or standard USB peripherals The 2433 integrates three SeaLATCH USB ports which are fully compatible with standard USB cables The metal thumbscrew on the included USB cable with a SeaLATCH USB type B connector provides a secure connection and prevents accidental cable disconnection Additionally the highly retentive type B connector h...

Страница 4: ... TR124 Wall mount AC power supply 5VDC 4A locking DC connector Advisory Conventions Warning The highest level of importance used to stress a condition where damage could result to the product or the user could suffer serious injury Important The middle level of importance used to highlight information that might not seem obvious or a situation that could cause the product to fail Note The lowest l...

Страница 5: ... is a standard AT style RS 232 modem cable with a DB9F connector on one end and a DB25M connector on the other This cable is 72 inches in length DB9F to DB9M Extension Cable Item CA127 The CA127 allows users to extend a DB9 cable up to six feet The connectors are pinned one to one so the cable is compatible with any device or cable that has DB9 connectors DB9F RS 422 to DB25M RS 530 Cable Item CA1...

Страница 6: ...ny cable with a DB9M connector Terminal Block Dual DB9F to 18 Screw Terminals Item TB06 The TB06 terminal block breaks out dual DB9 connectors to 18 screw terminals to simplify field wiring of serial connections including RS 422 and RS 485 networks The TB06 is designed to connect directly to Sealevel dual port DB9 serial cards or any cable with DB9M connectors Adapters and Converters DB9F to RJ45 ...

Страница 7: ...the listing 3 Click the Install Drivers button 4 The setup file will automatically detect the operating environment and install the proper components To confirm that the SeaCOM driver has been successfully installed click on the Start button and then select All Programs You should see the SeaCOM program folder listed You are now ready to proceed with connecting the 2433 to your system Refer to the...

Страница 8: ...Found New Hardware wizard will appear first for the root hub and then for each port that you are installing Follow the instructions on the following page to finish installation The installation will repeat twice for each COM port a total of 4 times on two port devices This is a limitation in the way Windows installs USB serial devices 1 Click on Install the software automatically followed by the N...

Страница 9: ...enu click Device Manager 3 Continue with step 4 below To access Device Manager in Windows 7 1 Right click on Computer in the Start menu 2 Click Manage in the fly out menu to launch the Computer Management console window 3 In the left pane under System Tools click Device Manager 4 In right pane near the bottom expand the Ports COM LPT section by clicking the symbol 5 You should now see the COM assi...

Страница 10: ... electrical interface follow the steps below 1 Open Device Manager and locate Ports COM LPT following the steps above You should see each of the 2433 s ports listed 2 Select one of the ports by right clicking on it and selecting Properties from the fly out menu The serial port properties menu will appear 3 Click on the Interface Settings tab The Sealevel SeaCOM driver adds the Interface Settings t...

Страница 11: ...lly for each mode The pull up PU and pull down PD resistor settings are shown in the table below Mode PU Setting PD Setting RS 232 Always Off Always Off RS 422 Always Off Always Off RS 485 Always On Always On Line Termination A 120 ohm resistor is across each RS 422 485 input If multiple devices are configured in an RS 485 network only the devices on each end should have the termination in place T...

Страница 12: ...12 Sealevel Systems Inc 2433 Manual SL9348 8 2021 HARDWARE CONFIGURATION CONTINUED Electrical Specificiations ...

Страница 13: ...o received This can be beneficial if the software can handle echoing i e using received characters to throttle the transmitter but it can also confuse the system if the software cannot support echoing Echo configuration is software selectable for half duplex RS 485 By default ECHO is disabled and this configuration can be set by placing a check next to Enable Echo in the RS 485 Advanced Configurat...

Страница 14: ...king connector and high retention type B port are shown below The 2433 also includes two convenient USB 1 1 hub ports on the front of the enclosure Each of the USB hub ports provides a full 500mA to peripheral devices The two locking USB hubs ports can secure peripherals to the device when used with USB cables with SeaLATCH type A connectors Item CA332 and CA355 Status LEDs Status LEDs on the fron...

Страница 15: ...ection of the power cable DB9M Serial Connectors The 2433 includes four DB9M serial connectors on the back of the device Pinouts for these connections are included in the Electrical Specifications section Input power is connected to pin 9 on each of the DB9M connectors for easily powering common 5V serial peripherals such as bar code scanners receipt printers and signature input devices Each seria...

Страница 16: ...e metal to metal connection and prevents accidental cable disconnection Sealevel incorporates SeaLATCH locking USB ports on many USB I O devices Accidental cable disconnection is the most common point of failure with USB industrial I O devices and SeaLATCH cables and connectors prevents that while being fully compatible with standard USB cables The image below shows the 2433 secured with included ...

Страница 17: ...rd USB type A connector This cable provides a secure connection between Sealevel products with a SeaLATCH type B port and legacy USB type A ports The CA356 is included with Sealevel devices with a SeaLATCH type B port Item CA332 The CA332 is a 72 cable with both SeaLATCH type A and B connectors This cable secures both ends of the cable to devices with SeaLATCH USB ports and offers complete protect...

Страница 18: ...rates to 921 6K bps The input power is connected to pin 9 on each of the DB9 connectors for conveniently powering 5 VDC serial peripheral devices at a maximum of 500mA per port Each DB9 serial port is fused at 500mA to protect the SeaLINK serial adapter from an over current situation Do not connect pin 9 to any devices that have Ring Indicator RI enabled Doing so can result in damage to your devic...

Страница 19: ...L9348 8 2021 ELECTRICAL SPECIFICATIONS CONTINUED Pin 9 provides 5VDC 500mA output RS 422 RS 485 Four Wire DB9 Male Pin Signal 1 RX 2 RX 3 TX 4 TX 5 GND 9 5VDC Pins 6 8 are no connect RS 485 Two Wire DB9 Male Pin Signal 3 DATA 4 DATA 5 GND ...

Страница 20: ...20 Sealevel Systems Inc 2433 Manual SL9348 8 2021 Silk Screen 2433 9 5VDC Pins 1 2 6 8 are no connect ...

Страница 21: ...g Storage Temperature Range 0º to 70º C 32º to 158º F 50º to 105º C 58º to 221º F Humidity Range 10 to 90 R H Non Condensing 10 to 90 R H Non Condensing Power Consumption Supply line 5 VDC Rating 4A Maximum via locking 2 1mm Barrel plug Manufacturing All Sealevel Systems printed circuit boards are built to UL 94V0 rating and are 100 electrically tested These printed circuit boards are solder mask ...

Страница 22: ...t is enabled and functioning properly in the operating system The presence of the Universal Serial Bus controllers listing in Device Manager will confirm that USB support is enabled in Windows 98 ME 2000 XP or Vista operating systems 4 While Device Manager is open locate the COM ports described under Verifying Installation in the Installation and Configuration section of this manual 5 Once you hav...

Страница 23: ...b select the COM port you want to test and click on the Open button Pictured below Click the Settings button to open the COM Properties menu Change your parameters to 9600 bits per second 8 data bits no parity 1 stop bit and no flow control as pictured below Click Apply and Ok ...

Страница 24: ... Transmit Frames and Receive Frames will increase The Tx and Rx Data Rates will show the calculated data rate Pictured below You can continue testing this port with different configurations or proceed with testing other ports if necessary If these steps do not solve your problem please call Sealevel Systems Technical Support 864 843 4343 Our technical support is free and available from 8 00 AM to ...

Страница 25: ...vides an FAQ section on its web site Please refer to this to answer many common questions This section can be found at http www sealevel com faq asp Sealevel Systems maintains a web page on the Internet Our home page address is www sealevel com The latest software updates and newest manuals are available via our web site Technical support is available Monday to Friday from 8 00 a m to 5 00 p m eas...

Страница 26: ...gic states The RS 232 and the EIA TIA 574 specification define two types of interface circuits Data Terminal Equipment DTE and Data Circuit Terminating Equipment DCE The IC485 is a DCE device RS 422 The RS 422 specification defines the electrical characteristics of balanced voltage digital interface circuits RS 422 is a differential interface that defines voltage levels and driver receiver electri...

Страница 27: ...allow for 32 drivers and 32 receivers to be connected to one line This interface is ideal for multi drop or network environments RS 485 tri state driver not dual state will allow the electrical presence of the driver to be removed from the line Only one driver may be active at a time and the other driver s must be tri stated RS 485 can be cabled in two ways two wire and four wire mode Two wire mod...

Страница 28: ...of the character is defined by the transmission of a pre defined number of stop bits usually 1 1 5 or 2 An extra bit used for error detection is often appended before the stop bits Asynchronous Communications Bit Diagram This special bit is called the parity bit Parity is a simple method of determining if a data bit has been lost or corrupted during transmission There are several methods for imple...

Страница 29: ...29 Sealevel Systems Inc 2433 Manual SL9348 8 2021 Appendix E Silk Screen 2433 Pin Signal 3 DATA 4 DATA 5 GND ...

Страница 30: ...30 Sealevel Systems Inc 2433 Manual SL9348 8 2021 9 5VDC ...

Страница 31: ...d to correct the interference at the user s expense EMC Directive Statement Products bearing the CE Label fulfill the requirements of the EMC directive 89 336 EEC and of the low voltage directive 73 23 EEC issued by the European Commission To obey these directives the following European standards must be met EN55022 Class A Limits and methods of measurement of radio interference characteristics of...

Страница 32: ...nty Warranty service may be obtained by delivering the Product to Sealevel and providing proof of purchase Customer agrees to ensure the Product or assume the risk of loss or damage in transit to prepay shipping charges to Sealevel and to use the original shipping container or equivalent Warranty is valid only for original purchaser and is not transferable This warranty applies to Sealevel manufac...