1. Read all instructions before connecting or 

operating this unit.

2. Retain this Owners Manual for future 

reference.  For technical assistance 

beyond what is covered in this manual 

contact Technical Service.

3. Save your carton!  ProSEAL laminators 

are shipped in special cartons and should 

be used in case your ProSEAL laminator 

should ever require service or need to be 

transported.

NOTICE! Failure to return machines 

properly packed in original packaging 

will impose a fifteen percent 

restocking fee plus costs to repair 

shipping damage.  Contact Technical 

Service for a return authorization (see 

rear cover). 

WARNING!  Do not modify the plug in 
any way.

IMPORTANT SAFEGUARDS

When using electrical appliances, basic 

precautions should always be taken to reduce 

the risk of electrical shock and injury to 

persons, including the following:

NOTE:  Disconnect the laminator from the 

main power supply before cleaning!

6.

Do  not  immerse  any  part  of  the 
laminator in water or other liquids.

7.

This unit should be situated away from heat 

sources such as heat register or 

stoves/ovens.

8.

The laminator's location or position should 

not interfere with its proper ventilation. Do 

not install or place in a built-in enclosure 

such as a bookcase.

9.

Do not operate the laminator with a 

damaged cord or plug, or after the laminator 

has been dropped or damaged in any 

manner. If purchased in U.S./Canada, 

return the laminator to SEAL Graphics or if 

purchased in Europe or Asia, return to your 

ProSEAL reseller for examination, repair or 

adjustment.

10. Do not let the cord hang over the edge of a 

counter/bench or touch hot surfaces.

11. Always unplug the laminator when it is not 

in use for a long period.

12. This unit should only be connected to a 

power supply outlet of the voltage, 

amperage, and frequency marked on the 

rear panel. The laminator has a grounded 

plug (three prongs). To reduce the risk of 

electrical shock, this plug is intended to fit 

only a grounded outlet of the proper 

amperage, and in only one way. If it does 

not fit in the outlet, contact a qualified 

electrician.

4.

Do not use the laminator for other 

than its intended use.

5.

The Laminator case may be cleaned 

with a lint-free cloth, lightly 

dampened with a mild soap and 

water solution.  Do not use spray-on 

cleaners.

All manuals and user guides at all-guides.com

Содержание PROSEAL 44

Страница 1: ...ProSEAL 44 Pouch Board Laminator ProSEAL 44 Laminator Owners Operation Manual All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...2 ProSEAL 44 Pouch Board Laminator All manuals and user guides at all guides com...

Страница 3: ...PANEL 8 MOUNTING USING A ProSEAL MOUNTING BOARD 9 MOUNTING USING A ProSEAL POUCH BOARD 10 ENCAPSULATING USING A ProSEAL FLEXIBLE POUCH 11 CLEANING YOUR LAMINATOR 12 TROUBLESHOOTING GUIDE 13 SPARE PAR...

Страница 4: ...been designed to be used with ProSEAL Pouch Boards and ProSEAL Flexible Pouches When used with these products you are able to laminate and encapsulate prints in one step Your laminator has not been te...

Страница 5: ...h as heat register or stoves ovens 8 The laminator s location or position should not interfere with its proper ventilation Do not install or place in a built in enclosure such as a bookcase 9 Do not o...

Страница 6: ...xist report this to the Freight Company or Dealer to file a claim Contact Technical Service see rear cover to determine if a replacement machine should be shipped to you NOTICE Retain original packagi...

Страница 7: ...rom the right hand side of the unit 3 Once the arrow has reached the desired nip setting release the knob or gently pull the knob out to lock it in place See Figure 1A Caution Set the Nip Control Knob...

Страница 8: ...ess temperature and is ready for use REVERSE Pressing and holding the top button reverses the direction of the rollers This is used to clear jams or foreign objects should one be drawn into the lamina...

Страница 9: ...he inlet opening Ensure the board will enter centered and straight A gentle push may be required to start the board into the laminator Hold the edges of the board until it is engaged in the unit and t...

Страница 10: ...matches the Pouch Board thickness Ensure that the unit is set to Hot Mode and that the LED is not flashing Slowly insert the Pouch Board into the inlet opening Ensure that the Pouch Board will enter c...

Страница 11: ...assist in the handling of large Flexible Pouches It is made of materials that will not damage or cause excessive wear to your ProSEAL Laminator 5 Adjust the Control Knob to the 3 16 5mm setting for t...

Страница 12: ...output Adhesive build up may eventually damage the rollers When laminating a small amount of adhesive will squeeze out between the laminate films and onto the top and bottom rollers This residue accu...

Страница 13: ...king a louder humming noise and or it is stalling Only after pushing very hard the board is accepted Reset the main circuit breaker at the service panel The main circuit breaker is tripped Replace fus...

Страница 14: ...4LR3002A TABLE FRONT 026004005A FOOT 380LR4001A POWER CORD 350LR3025A PCB CONTROL ASS Y 350LR3026A PCB MAIN ASS Y 032LR3013A INLAY CONTROL Please contact your distributor or sales person for replaceme...

Страница 15: ...Board An adhesive coated board used for mounting images Nip The spot where the top and bottom rollers meet Out Feed The back of the laminator where completed images emerge Pouch Board An adhesive coat...

Страница 16: ...Process Speed 44 1120 mm Maximum Working Width Process 122 lbs 55 kg Shipping Weight 111 lbs 50 kg Net Weight 20 510 mm Depth 53 1350 mm Overall Width 12 300 mm Height Mechanical Specifications are su...

Страница 17: ...s representative for details Note Used and Not Refurbished Equipment is sold on an AS IS basis with No Warranty For more information regarding this warranty please contact your distributor WARNING Any...

Страница 18: ...486 6502 Fax 1 800 966 4554 SEAL CUSTOMER SERVICE For information and placing orders Tel 1 800 257 7325 Fax 1 800 966 4554 Specification subject to change without notice Seal Graphics Americas Corpor...

Отзывы: