background image

 

 

 

 

 

 

 

 

 

7

1. Place dehumidifier on a level surface.

    • Do not place unit directly on vapor barrier. For example, use blocks 

      or pavers to create a level surface. 

    • If unit has been turned or flipped so that the compressor did not

      remain upright, place the unit on a level surface and wait a

      minimum of 2 hours before proceeding.

2. Set up the drain line

    • The drain line should be routed to a suitable drain on the outside.

    • THE DRAIN MUST FLOW DOWN WITH NO LOOPS OR DIPS.

    •

 Recommended Drain Option- Transition to PVC Pipe

      

1. Cut a piece of 3/4”OD PVC that is approx. 6” long.

       2. Insert cut PVC into a 3/4” elbow.

       3. Attach PVC+elbow to a 3/4”OD length of PVC to drain. 

       Keep the length of PVC as short as possible.

       4. Insert the open end of dehumidifier drain tube into 6” 

       piece of PVC so that it does not extend into elbow fitting. 

       5. For a proper flow, a minimum downward slop of 1” per 

      10’ run is required.

       6. Support the PVC tubing so that it maintains a smooth downward flow to drain.

3. Plug unit into a dedicated, 15 amp GFCI protected circuit.

             

 

 

  

                                 

• The display screen has two functions:

        1. When the unit is powered on, it shows the humidity of the space

        2. When setting the desired humidity level, the screen will show the

        set point. After a brief delay, it will revert to current humidity of the 

        space.  

         

• This light indicates that the unit is properly powered on and ready to

operate. 

• Always make sure the unit is “off” prior to performing any service, unless

otherwise indicated.

• If the humidity is above the setpoint, the light will be solid green and the 

machine will operate.

• If the humidity is below the setpoint, the unit will be in standby mode and 

the light will be flashing. 

        

         

• When the light illuminates green, it indicates that the dehumidifier

is set to continuous operation mode.

• When the light illuminates red, it means the unit is in auto defrost mode

and clearing the evaporate coils of any ice buildup.   

         

         

• When the light illuminates red, it indicates the compressor has been

initiated but is currently warming up. 

• Once the light switches to green, it means the compressor is currently

in working status.

         

         

Remote Control Instructions

 

WatchDog Dehumidifiers can be controlled using an optional remote

accessory. The remote connects to your dehumidifier via a 25’ CAT 5

cable, with the integrated sensor giving you multiple options for 

monitoring surrounding conditions. 

Example #1- Install the dehumidifier in the laundry room and 

duct it into the living room. Mount the remote in the living room and use 

the remote sensor.

Example #2- Install the dehumidifier in your crawl space with 

the remote mounted in your garage. 

NOTE: The symbols indicated below only 
show when the remote is powered on. 

 

         

1. On/Off (Power) Button

Press the on/off button and the

machine will start running (two

beeps). Press the button again

to turn the machine off. 

         

2. Up Button/ Down Button

Use the up and down arrows to

adjust the humidity level. 

         

3. Mode

Use the mode button to switch between dehumidifier and a ducted

application.

        • The      symbol on the display indicates the sensor on the 

           remote control is being utilized.

        • The     symbol on the display indicates the sensor on the 

          dehumidifier is being utilized. 

 

 

 f

           

4. Temperature

Press the temperature button to display the current temperature on the 

screen 

         

5. Continuous 

Press this button to switch the unit into continuous mode. “CONT.” will

appear on the display screen. 

         

6. Drain Pump 

This button is not applicable for WatchDog NXT85 models.  

         

Содержание WatchDog NXT85

Страница 1: ...Installation and Operations Manual Seaira Global LLC 14021 NC Highway 50 Surf City NC 28445 910 660 0962 WatchDog NXT85 ...

Страница 2: ...How it Works Installation Requirements Installation Key Functions Indicator Lights Remote Control Operating Instructions Unit Diagram Maintenance Dehumidifier Storage Ducted Applications Troubleshooting Spare Parts Warranty Information 2 2 3 3 3 4 4 6 7 8 9 9 11 11 12 13 14 ...

Страница 3: ...cted with at least 15 amp capacity The use of any other type of wiring will void your warranty Install dehumidifier according to all applicable local state and national codes Be sure to follow your GFCI manufacturer s maintenance instructions You will typically need to test the operation of the trip circuit monthly For ease of testing and operation it may be helpful to put the test switch and indi...

Страница 4: ...s an evaporator coil which is cooler than the dew point of air This means moisture will condense out of the air The air is then reheated through the condenser coil and distributed back into the room Installation Requirements The area where the dehumidifier is located should be sealed with a vapor barrier If the unit is installed in a crawl space all vents should be sealed For proper ventilation ne...

Страница 5: ...C into a 3 4 elbow 3 Attach PVC elbow to a 3 4 OD length of PVC to drain Keep the length of PVC as short as possible 4 Insert the open end of dehumidifier drain tube into 6 piece of PVC so that it does not extend into elbow fitting 5 For a proper flow a minimum downward slop of 1 per 10 run is required 6 Support the PVC tubing so that it maintains a smooth downward flow to drain 3 Plug unit into a...

Страница 6: ...osed on the external device Note that you may need to unplug the unit to reset the error code To set the unit to run continuously regardless of humidity simply use the down arrow key to set the humidity below 36 The continuous light will illuminate green and the display will show CO 3 Continuous Mode Use the up and down arrows to set the desired humidity setpoint on the display screen The setpoint...

Страница 7: ...cated If the humidity is above the setpoint the light will be solid green and the machine will operate If the humidity is below the setpoint the unit will be in standby mode and the light will be flashing 3 Continuous Mode Auto Defrost Light When the light illuminates green it indicates that the dehumidifier is set to continuous operation mode When the light illuminates red it means the unit is in...

Страница 8: ...ote is powered on 1 On Off Power Button Press the on off button and the machine will start running two beeps Press the button again to turn the machine off 2 Up Button Down Button Use the up and down arrows to adjust the humidity level 3 Mode Use the mode button to switch between dehumidifier and a ducted application The symbol on the display indicates the sensor on the remote control is being uti...

Страница 9: ...se the up and down arrow keys to adjust your desired setpoint typically 50 55 3 Stop the machine Press the power button again and the dehumidifier will stop Note that the fan will continue to operate for 1 minute after the unit has shut off DO NOT DISCONNECT THE POWER CORD TO FORCE THE UNIT TO STOP 4 Water Drainage ...

Страница 10: ...ore doing any maintenance Cleaning the Machine Body Use a soft damp cloth to clean the exterior of unit Do not use any soap or solvents Coil Maintenance Once per year clean the coils with an approved coil cleaner The coil cleaner should be a self rinsing foaming cleaner such as WEB Coil Cleaner Unit Diagram ...

Страница 11: ...n the control board cover Mix a 16 ounce solution of bleach 1 oz bleach 15 oz water OR vinegar 4 oz white vinegar 12 oz water Remove filter s so you have access to the drain tray Disconnect power to dehumidifier Pour the cleaning solution into the drain tray at the base of the coils If any cleaning solution gets on the coils flush with water Allow solution to soak for 15 minutes Pour in 16 32 ounc...

Страница 12: ...difier allows the unit to be in one room while conditioning an adjacent room Both the inlet return grille and the supply grille are designed for 10 flex ducting Ducting Installation Notes Be sure to secure the ducting with tie wrap Maximum total length of duct run 10 Inlet and outlet duct adapters are optional accessories Duct Adapter Installation Screw in the 4 screws on each duct adapter Flex Du...

Страница 13: ...12 Troubleshooting ...

Страница 14: ...13 Spare Parts ...

Страница 15: ... the day the shipment left the warehouse Please be sure to record serial and date of installation in the spaces provided on page 2 of the manual You will need this information to receive an RA number 2 If warranty service is necessary customer must contact Seaira Global Tech Support by phone 910 660 0962 to receive a Return Authorization RA number 3 Once an RA has been issued it is the customer s ...

Страница 16: ...ND LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED IN LAW OR IN FACT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE SEAIRA GLOBAL S TOTAL LIABILITY REGARDLESS OF NATURE OF CLAIM SHALL NOT EXCEED ORIGINAL PURCHASE PRICE OF THE PRODUCT IF A PRODUCT OR COMPONENT IS REPLACED WHILE UNDER WARRANTY THE APPLICABLE WARRANTY PERIOD SHALL NOT...

Отзывы: