• Always connect your dehumidifier using a grounded, dedicated

  electrical connection that is GFCI protected with at least 15 amp capacity.

      •The use of any other type of wiring will void your warranty.

• Install dehumidifier according to all applicable local, state, and national

  codes

• Be sure to follow your GFCI manufacturer’s maintenance instructions.

  You will typically need to test the operation of the trip circuit monthly. 

      • For ease of testing and operation, it may be helpful to put the test

        switch and indicator lights in a convenient location. 

• Your dehumidifier should only be repaired by a qualified technician. 

• Do not insert objects or your fingers into the inlet or discharge.

• Do not use water to clean the exterior of the dehumidifier. To clean unit, 

  unplug from power, then use a damp cloth to wipe the exterior. 

• Do not stand on dehumidifier or place objects on it.

• Do not use with extension cord or plug adapter.

• Unless otherwise noted, all maintenance should be done with the unit 

  powered off.

 

 

                         

Model Number:                                  Date Of Purchase: 

                                       

Specifications

 

Capacity @ 80°F/60%RH:  

120 Pints Per Day

Airflow @ 0.0” SP:

  300CFM

Operating Temp. Range:

  33-105°F

Operating Relative Humidity Range:

  36%-90%

COP:  

2.8 L/kWh

Refrigerant:  

R410A

Amperage Usage:

  7.6 Amps

Power Supply:

  115V/60Hz/Single Phase

Outlet Requirement:

  15 Amp, 3 Prong, GFCI

Sound Level:

  60 dBa

Dimensions

 

LxWxH:

  23.75” x 14” x 16”

ETL Listed:

  Yes

 

                                       

How It Works

 

WatchDog dehumidifiers use an integrated humidistat to monitor the 

conditioned space. When the relative humidity goes above the selected 

setpoint, the dehumidifier will energize. Air is then drawn across an

evaporator coil, which is cooler than the dew point of air. This means moisture 

will condense out of the air. The air is then reheated through the condenser 

coil and distributed back into the room. 

                                 

Installation Requirements 

• The area where the dehumidifier is located should be sealed with a vapor 

barrier.

• If the unit is installed in a crawl space, all vents should be sealed.

• For proper ventilation, neither the inlet or discharge should be positioned 

against a wall. The inlet needs a minimum of 12” clearance and the discharge 

requires a minimum of 36” clearance.

• For the best air diffusion, install the unit so that a side panel faces the wall.

• WatchDog dehumidifiers are only intended for operation when the unit 

is upright and level with the feet on the ground (unless using a WatchDog

Hanging Kit). 

                                 

Содержание WatchDog NXT120C

Страница 1: ...Installation and Operations Manual Seaira Global LLC 14021 NC Highway 50 Surf City NC 28445 910 660 0962 WatchDog NXT120C...

Страница 2: ...ow it Works Installation Requirements Installation Key Functions Indicator Lights Remote Control Operating Instructions Unit Diagram Maintenance Dehumidifier Storage Ducted Applications Troubleshootin...

Страница 3: ...charge Do not use water to clean the exterior of the dehumidifier To clean unit unplug from power then use a damp cloth to wipe the exterior Do not stand on dehumidifier or place objects on it Do not...

Страница 4: ...il which is cooler than the dew point of air This means moisture will condense out of the air The air is then reheated through the condenser coil and distributed back into the room Installation Requir...

Страница 5: ...Functions 1 Power Key Use this button to turn the dehumidifier on and off Press once to turn machine on You will hear two beeps and the light will illuminate green solid or flashing depending on mode...

Страница 6: ...ically and the display will show E4 After a 1 minute delay the fan motor will turn off and the dehumidifier will not operate until the problem has been resolved Check to verify that the pump is functi...

Страница 7: ...ted If the humidity is above the setpoint the light will be solid green and the machine will operate If the humidity is below the setpoint the unit will be in standby mode and the light will be flashi...

Страница 8: ...he machine will start running Press the button againto turn the machine off 2 Up Button Down Button Use the up and down arrows to adjust the humidity level 3 Mode Use the mode button to switch between...

Страница 9: ...continue to operate for 1 minute after the unit has shut off DO NOT DISCONNECT THE POWER CORD TO FORCE THE UNIT TO STOP 4 Water Drainage The WatchDog NXT120c has an integrated condensate pump During...

Страница 10: ...re doing any maintenance Cleaning the Machine Body Use a soft damp cloth to clean the exterior of unit Do not use any soap or solvents Coil Maintenance Once per year clean the coils with an approved c...

Страница 11: ...e desired drain The pump requires routine maintenance that is not covered by the warranty Preventative maintenance is necessary to prevent issues from dirt and slime that may accumulate in the drain s...

Страница 12: ...l does not appear clean move on to Advanced Cleaning Complete about once per year depending on environment Advanced Pump Cleaning Complete as needed 1 Press the drain button to drain the water from th...

Страница 13: ...Ducted Applications Ducting the dehumidifier allows the unit to be in one room while conditioning an adjacent room Both the inlet return grille and the supply grille are designed for 10 flex ducting D...

Страница 14: ...13 Troubleshooting...

Страница 15: ...if the pump is operational by pressing the drain button Check if the pump energizes and de energizes properly Additionally check to see if any water purged from the system 3 If you haven t cleaned th...

Страница 16: ...e day the shipment left the warehouse Please be sure to record serial and date of installation in the spaces provided on page 2 of the manual You will need this information to receive an RA number 2 I...

Страница 17: ...D LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED IN LAW OR IN FACT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE SEAIRA GLOBAL S TO...

Отзывы: