12
Momentus Product Manual, Rev. A
3.9.2
Conducted noise
Input noise ripple is measured at the host system power supply across an equivalent 15-ohm resistive load on
the +5V line.
Using 5V power, the drive is expected to operate with a maximum of 100mV peak-to-peak square-wave
injected noise at up to 10 MHz.
Note.
Equivalent resistance is calculated by dividing the nominal voltage by the typical RMS read/write
current.
3.9.3
Voltage tolerance
Voltage tolerance (including noise):
5V
±
5%