Momentus 4200.3 PATA Product Manual, Rev. B

4.1.1

Supported ATA commands

The following table lists ATA-standard commands that the drive supports. For a detailed description of the ATA 
commands, refer to the Draft ATA-6 Standard.

Table 7: 

Supported commands

Command name

Command code (in hex)

ATA-standard commands

ATA Device Configuration Overlay

B1

H

ATA Service

A2

H

Check Power Mode

98

H,  

E5

H

Download Microcode

92

H

Execute Device Diagnostics

90

H

Flush Cache

E7

H

Flush Cache Extended

EA

H

Format Track (Legacy)

50

H

Identify Device

EC

H

Idle

97

H,  

E3

H

Idle Immediate

95

H,  

E1

H

Initialize Device Parameters

91

H

Read Buffer

E4

H

Read DMA 

C8

H, 

C9

H

Read DMA Extended

25

H

Read Log Extended

22

H

Read Multiple

C4

H

Read Multiple Extended

29

H

Read Native Max Address

F8

H

Read Native Max Address Extended

27

H

Read Sectors 

20

H, 

21

H

Read Sectors Extended

24

H

Read Verify Sectors 

40

H, 

41

H

Read Verify Sectors Extended

42

H

Recalibrate

10

H

Security Disable Password

F6

H

Security Erase Prepare

F3

H

Security Erase Unit

F4

H

Security Freeze Lock

F5

H

Security Set Password

F1

H

Содержание ST9408116A

Страница 1: ...Product Manual Momentus 4200 3 100398880 Rev B August 2007 ST980811A ST960813A ST9408116A...

Страница 2: ...States and or other countries All other trademarks or registered trademarks are the property of their respective owners One gigabyte or GB equals one billion bytes and one terabyte or TB equals one tr...

Страница 3: ...ity 17 2 14 Agency certification 17 2 14 1 Safety certification 17 2 14 2 Electromagnetic compatibility 17 2 14 3 FCC verification 18 2 15 Environmental protection 19 2 15 1 European Union Restriction...

Страница 4: ...ii Momentus 4200 3 PATA Product Manual Rev B...

Страница 5: ...mentus 4200 3 PATA Product Manual Rev B iii List of Figures Figure 1 Typical 5V startup and operation current profile 12 Figure 2 Jumper settings 22 Figure 3 Mounting dimensions top side and end view...

Страница 6: ...iv Momentus 4200 3 PATA Product Manual Rev B...

Страница 7: ...5 Tunneling Magnetoresistive TMR recording heads State of the art cache and on the fly error correction algorithms Full track multiple sector transfer capability without local processor intervention 9...

Страница 8: ...2 Momentus 4200 3 PATA Product Manual Rev B...

Страница 9: ...C and nominal power For convenience the phrases the drive and this drive are used throughout this manual to indicate ST980811A ST960813A and ST9408116A model drives 2 1 Specification summary The spec...

Страница 10: ...ical 3 0 Standby to ready sec typical 3 0 Track to track seek time msec typical 1 0 read 1 5 write Average random seek write msec typical 13 0 Average random seek read msec typical 11 0 Average random...

Страница 11: ...5 500 Hz Drive acoustics sound power bels 2 disc Idle 2 4 typical 2 6 max Performance seek 2 9 typical 3 1 max Nonrecoverable read errors 1 per 1014 bits read Annualized Failure Rate AFR 0 60 Load Un...

Страница 12: ...dby to ready sec typical 3 0 Track to track seek time msec typical 1 0 read 1 5 write Average random seek write msec typical 13 0 Average random seek read msec typical 11 0 Average random seek msec ty...

Страница 13: ...peak 5 500 Hz Drive acoustics sound power bels 2 disc Idle 2 4 typical 2 6 max Performance seek 2 9 typical 3 1 max Nonrecoverable read errors 1 per 1014 bits read Annualized Failure Rate AFR 0 60 Lo...

Страница 14: ...e drives in LBA mode all blocks sectors are consecutively numbered from 0 to n 1 where n is the number of guaranteed sectors as defined above 2 4 Physical organization Model Formatted capacity Guarant...

Страница 15: ...pical 835k Track density TPI tracks inch typical 150k Areal density Gbits inch2 max 132 Spindle speed RPM 0 2 5 400 Internal data transfer rate OD Mbits sec max 352 I O data transfer rate Mbytes sec m...

Страница 16: ...ured in performance mode Note These drives are designed to consistently meet the seek times represented in this manual Physical seeks regardless of mode such as track to track and average are expected...

Страница 17: ...perations every 100 msecs This mode is not typical Read write power and current Read write power is measured with the heads on track based on three 63 sector read or write operations every 100 msecs I...

Страница 18: ...host system power supply across an equivalent 15 ohm resistive load on the 5 volt line Using 5 volt power the drive is expected to operate with a maximum of 100 mV peak to peak square wave injected n...

Страница 19: ...time disc access is necessary Sleep mode The drive enters Sleep mode after receiving a Sleep command from the host In Sleep mode the drive buffer is in Self Refresh Low Power mode the heads are parke...

Страница 20: ...very 1000 feet 2 10 2 Temperature gradient 2 10 3 Humidity 2 10 3 1 Relative humidity 2 10 3 2 Wet bulb temperature 2 10 4 Altitude Operating 0 to 60 C 32 to 140 F Nonoperating 40 to 70 C 40 to 158 F...

Страница 21: ...bsequently put into operation is 900 Gs based on a nonrepetitive half sine shock pulse of 1 msec duration The nonoperating shock level that the drive can experience without incurring physical damage o...

Страница 22: ...in the following table A 1 No upset or degradation in performance beyond manufacturer s specified limits 2 No data loss B 1 Unit self recovers without user intervention 2 No data loss C 1 Upset OK pro...

Страница 23: ...rantee that all systems will comply with the directives The drive is designed for operation inside a properly designed enclosure with properly shielded I O cable if necessary and terminators on all un...

Страница 24: ...ology LLC has tested this device in enclosures as described above to ensure that the total assembly enclosure disc drive motherboard power supply etc does comply with the limits for a Class B computin...

Страница 25: ...clude standard operat ing procedures that ensure that restricted substances are not utilized in our manufacturing operations labora tory analytical validation testing and an internal auditing process...

Страница 26: ...20 Momentus 4200 3 PATA Product Manual Rev B...

Страница 27: ...e handling the drive put on a grounded wrist strap or ground yourself frequently by touching the metal chassis of a computer that is plugged into a grounded outlet Wear a grounded wrist strap througho...

Страница 28: ...ion 3 2 2 The Master or single drive option is the factory default setting Figure 5 Jumper settings 3 2 2 Cable select option Computers that use cable select determine the master and slave drives by s...

Страница 29: ...rew engagement recommended Measurements shown in Figure 6 are in inches Figure 6 Mounting dimensions top side and end view BOTH SIDES 2 2 12 MIN FULL THREAD 2X M3 X 0 5 6H MOUNTING HOLES BOTH SIDES 0...

Страница 30: ...24 Momentus 4200 3 PATA Product Manual Rev B...

Страница 31: ...or pins The following table summarizes the signals on the 44 pin ATA interface connector For a detailed description of these signals refer to the Draft ATA 6 Standard Table 6 Connector signals Signal...

Страница 32: ...evice Diagnostics 90H Flush Cache E7H Flush Cache Extended EAH Format Track Legacy 50H Identify Device ECH Idle 97H E3H Idle Immediate 95H E1H Initialize Device Parameters 91H Read Buffer E4H Read DMA...

Страница 33: ...tandby Immediate 94H E0H Vendor Unique 9AH FAH FBH Write Buffer E8H Write DMA CAH CBH Write DMA Extended 35H Write Log Extended 32H Write Multiple C5H Write Multiple Extended 39H Write Sectors 30H 31H...

Страница 34: ...28 Momentus 4200 3 PATA Product Manual Rev B Security Freeze Lock F5H Security Disable Password F6H Table 7 Supported commands Command name Command code in hex...

Страница 35: ...16 383 2 ATA reserved 0000H 3 Number of logical heads 16 4 Retired 0000H 5 Retired 0000H 6 Number of logical sectors per logical track 63 003FH 7 9 Retired 0000H 10 19 Serial number 20 ASCII character...

Страница 36: ...m PIO cycle time with IORDY flow control 120 nsec 0078H 69 74 ATA reserved 0000H 75 Queue depth 0000H 76 79 ATA reserved 0000H 80 Major version number 007EH 81 Minor version number 0000H 82 Command se...

Страница 37: ...tive 10 Multiword DMA mode 2 is currently active Bit Word 88 0 Ultra DMA mode 0 is supported 1 Ultra DMA mode 1 is supported 2 Ultra DMA mode 2 is supported 3 Ultra DMA mode 3 is supported 4 Ultra DMA...

Страница 38: ...set the default values of the features are as indicated above Table 8 Features register values 02H Enable write cache default 03H Set transfer mode based on value in Sector Count register Sector Count...

Страница 39: ...Refer to your system manufacturer s support website for the most up to date information Read and follow all instructions regarding the proper steps to be taken when replacing the system hard drive Som...

Страница 40: ...150 Inspirion 2650 Inspirion 300M Inspirion 5100 Inspirion 5150 Inspirion 600M Inspirion 8600 Inspirion 9100 Inspirion XPS Intel 845GBV Intel SPRINGDALE G Intellistation EPVO Intellistation M PRO JIA...

Страница 41: ...systems Table 10 Tested BIOS versions Vendor Release Revision ACER 1 01 ACPI Ver 1 20 AMI Various Various Apple 4 71F1 Apple 4 8 4F1 Award Various Various Compal 38118 v2 00 Compaq 68xxx Various Compa...

Страница 42: ...s an exclusive disc drive diagnostic software designed to troubleshoot most hard drive issues Desktop edition works with most ATA SATA or SCSI drives in desktop systems and has a 98 percent accuracy r...

Страница 43: ...s with product information program benefits and sales tools You may register for customized communications that are not available on the web These communications contain product launch EOL pricing pro...

Страница 44: ...vailable on a global basis for the return of defective products Contact your customer support representative for the location nearest you USA Canada Latin America support services For an extensive lis...

Страница 45: ...ins 25 Corrosive environment 19 CSA C22 2 950 17 CSEL 22 C Tick 18 current profile 12 cycles 17 D Data Defense 1 data transfer rates 1 DC power 11 demonstrate compliance 36 density 9 Diagnostic Defens...

Страница 46: ...ins 25 PIO 25 power consumption 11 power dissipation 11 power frequency h field immunity 16 power management 13 power on off cycles 17 power specifications 11 power management commands 27 power manage...

Страница 47: ...inup 11 spinup power 11 Standby 11 27 Standby Immediate 27 Standby mode 11 13 Standby to Ready 10 static discharge precautions 21 subassembly 18 support services 37 surge immunity 16 T technical suppo...

Страница 48: ...42 Momentus 4200 3 PATA Product Manual Rev B...

Страница 49: ......

Страница 50: ...Seagate Technology LLC 920 Disc Drive Scotts Valley California 95066 4544 USA Publication Number 100398880 Rev B Printed in U S A...

Отзывы: