Momentus 4200.2 Product Manual, Rev. D
13
2.11
Acoustics
Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea-
surements are consistent with ISO document 7779. Sound power measurements are taken under essentially
free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.
Note.
For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is
defined by the following equation:
Number of seeks per second = 0.4 / (average l average access time)
*During periods of drive idle, some offline activity may occur, according to the S.M.A.R.T. specification, which may increase acoustic and
power to operational levels.
2.12
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:
A - 1) No upset or degradation in performance beyond manufacturer’s specified limits.
2) No data loss.
B - 1) Unit self recovers without user intervention.
2) No data loss.
C - 1) Upset OK provided that unit will function after user intervention.
Table 4:
Drive level acoustics
Acoustic mode
Idle*
Quiet Seek
Performance Seek
2.4 bels (typ)
2.6 bels (max)
2.6 bels (typ)
2.8 bels (max)
2.9 bels (typ)
3.1 bels (max)
Table 5:
Electromagnetic immunity
Test
Description
Performance
level
Reference
standard
Electrostatic discharge
Contact, HCP, VCP: ± 4
kV; Air:
± 8 kV
B
EN 61000-4-2: 95
Radiated RF immunity
80 to 2,000 MHz, 10 V/m,
80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse modulation @ 200
Hz
A
EN 61000-4-3: 96
ENV 50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN 61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common, AC mains
B
EN 61000-4-5: 95
Conducted RF immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1
kHz sine
A
EN 61000-4-6: 97
Power Frequency H-field
immunity
1 A/m, 50Hz/60Hz, 3 axes
A
EN 61000-4-8: 97
Voltage dips, interrupts
30% Reduction for 25 cycles
>95% Reduction for 250 cycles
>95%, 0.5 cycles
C
C
B
EN 61000-4-11: 94