S
AVVIO
10K.6 SAS P
RODUCT
M
ANUAL
, R
EV
. C
23
[1]
Measured with average reading DC ammeter. Instant12V current peaks will exceed these values. Power supply at nominal
voltage. N (number of drives tested) = 6, 35 Degrees C ambient.
[2]
For +12 V, a –10% tolerance is allowed during initial spindle start but must return to ±5% before reaching 9,936 RPM. The ±5% must
be maintained after the drive signifies that its power-up sequence has been completed and that the drive is able to accept selection
by the host initiator.
[3]
See +12V current profile in Figure 1 (for 900GB models) and Figure 2 (for 600GB models).
[4]
See +12V current profile in Figure 3 (for 450GB models) and Figure 4 (for 300GB models).
[5]
This condition occurs after OOB and Speed Negotiation completes but before the drive has received the Notify Spinup primitive.
[6]
See paragraph 6.3.1, "Conducted noise immunity." Specified voltage tolerance includes, noise, and transient response.
[7]
Operating condition is defined as random 8 block reads.
[8]
During idle, the drive heads are relocated every 30 seconds to a random location within the band from three-quarters to maximum
track.
Table 4
300GB standard model DC power requirements
N
OTES
3.0G
B MODE
6.0G
B MODE
(A
MPS
)
(A
MPS
)
(A
MPS
)
(A
MPS
)
Voltage
+5V
+12V [2]
+5V
+12V [2]
Regulation
[6]
±5%
±5% [2]
±5%
±5% [2]
Avg idle current DC
[1] [8]
0.32
0.12
0.32
0.12
Advanced Idle Current
Idle_A
3
σ
0.37
0.13
0.36
0.13
Idle_B
3
σ
0.25
0.11
0.25
0.11
Idle_C
3
σ
0.25
0.05
0.25
0.05
Standby
3
σ
0.24
0.01
0.24
0.01
Maximum starting current
(peak DC) DC
3
σ
[4]
0.82
0.80
0.87
0.80
(peak AC) AC
3
σ
[4]
1.05
1.84
1.07
2.47
Delayed motor start (max) DC
3
σ
[1] [5]
0.24
0.01
0.24
0.01
Peak operating current (random read):
Typical DC
[1] [7]
0.41
0.39
0.41
0.40
Maximum DC
3
σ
[1]
0.45
0.42
0.46
0.42
Maximum (peak) DC
3
σ
1.53
1.27
1.61
1.30
Peak operating current (random write)
Typical DC
0.42
0.31
0.42
0.31
Maximum DC
3
σ
0.46
0.33
0.45
0.33
Maximum (peak) DC
3
σ
1.01
1.28
1.08
1.30
Peak operating current (sequential read)
Typical DC
0.82
0.13
0.83
0.13
Maximum DC
3
σ
0.88
0.14
0.88
0.14
Maximum (peak) DC
3
σ
1.06
0.41
1.07
0.41
Peak operating current (sequential write)
Typical DC
0.78
0.13
0.78
0.13
Maximum DC
3
σ
0.81
0.14
0.82
0.14
Maximum (peak) DC
3
σ
1.05
0.44
1.00
0.42