Each cache segment is actually a self-contained circular buffer whose length is an integer number of logical blocks. The 
drive dynamically creates and removes segments based on the workload. The wrap-around capability of the individual 
segments greatly enhances the cache’s overall performance.

Note.

The size of each segment is not reported by Mode Sense command page 08h, bytes 14 and 15. The value 
0XFFFF is always reported regardless of the actual size of the segment. Sending a size specification using the 
Mode Select command (bytes 14 and 15) does not set up a new segment size. If the STRICT bit in Mode page 
00h (byte 2, bit 1) is set to one, the drive responds as it does for any attempt to change an unchangeable param-
eter.

4.5.1

Caching write data 

Write caching is a write operation by the drive that makes use of a drive buffer storage area where the data to be written to 
the medium is stored while the drive performs the Write command. 

If read caching is enabled (RCD=0), then data written to the medium is retained in the cache to be made available for future 
read cache hits. The same buffer space and segmentation is used as set up for read functions. The buffer segmentation 
scheme is set up or changed independently, having nothing to do with the state of RCD. When a write command is issued, if 
RCD=0, the cache is first checked to see if any logical blocks that are to be written are already stored in the cache from a 
previous read or write command. If there are, the respective cache segments are cleared. The new data is cached for 
subsequent Read commands.

If the number of write data logical blocks exceed the size of the segment being written into, when the end of the segment is 
reached, the data is written into the beginning of the same cache segment, overwriting the data that was written there at the 
beginning of the operation; however, the drive does not overwrite data that has not yet been written to the medium.

If write caching is enabled (WCE=1), then the drive may return Good status on a write command after the data has been 
transferred into the cache, but before the data has been written to the medium. If an error occurs while writing the data to the 
medium, and Good status has already been returned, a deferred error will be generated.

The Synchronize Cache command may be used to force the drive to write all cached write data to the medium. Upon 
completion of a Synchronize Cache command, all data received from previous write commands will have been written to the 
medium. Section 11.3.2 shows the mode default settings for the drive.

4.5.2

Prefetch operation

If the Prefetch feature is enabled, data in contiguous logical blocks on the disk immediately beyond that which was requested 
by a Read command are retrieved and stored in the buffer for immediate transfer from the buffer to the host on subsequent 
Read commands that request those logical blocks (this is true even if cache operation is disabled). Though the prefetch 
operation uses the buffer as a cache, finding the requested data in the buffer is a prefetch hit, not a cache operation hit.

To enable Prefetch, use Mode Select page 08h, byte 12, bit 5 (Disable Read Ahead - DRA bit). DRA bit = 0 enables prefetch.

The drive does not use the Max Prefetch field (bytes 8 and 9) or the Prefetch Ceiling field (bytes 10 and 11).

When prefetch (read look-ahead) is enabled (enabled by DRA = 0), the drive enables prefetch of contiguous blocks from the 
disk when it senses that a prefetch hit will likely occur. The drive disables prefetch when it decides that a prefetch hit is not 
likely to occur.

Содержание ST1200MM0007

Страница 1: ...ate Enterprise Performance 10K HDD v7 100713202 Rev C July 2013 Standard Models ST1200MM0007 Self Encrypting Drive Models ST1200MM0017 SED FIPS 140 2 Models ST1200MM0027 SED ISE Models ST1200MM0037 In...

Страница 2: ...e gigabyte or GB equals one billion bytes and one terabyte or TB equals one trillion bytes Your computer s operating system may use a different standard of measurement and report a lower capacity In a...

Страница 3: ...9 4 2 PERFORMANCE CHARACTERISTICS 9 4 2 1 Format command execution time for 512 byte sectors minutes 9 4 2 2 General performance characteristics 9 4 3 START STOP TIME 10 4 4 PREFETCH MULTI SEGMENTED C...

Страница 4: ...assword 28 8 3 RANDOM NUMBER GENERATOR RNG 29 8 4 DRIVE LOCKING 29 8 5 DATA BANDS 29 8 6 CRYPTOGRAPHIC ERASE 29 8 7 AUTHENTICATED FIRMWARE DOWNLOAD 30 8 8 POWER REQUIREMENTS 30 8 9 SUPPORTED COMMANDS...

Страница 5: ...ense data 43 11 4 MISCELLANEOUS OPERATING FEATURES AND CONDITIONS 45 11 4 1 SAS physical interface 45 11 4 2 Physical characteristics 48 11 4 3 Connector requirements 48 11 4 4 Electrical description...

Страница 6: ...wer vs input output operations per second 22 Figure 4 Location of the HDA temperature check point 23 Figure 5 Recommended mounting 24 Figure 6 Mounting configuration dimensions 26 Figure 7 Example of...

Страница 7: ...umbers business hours Authorized Service Centers For information regarding Warranty Support visit http www seagate com support warranty and replacements For information regarding data recovery service...

Страница 8: ...roducts and need further assistance please contact the Field Applications Engineer FAE or our global support services group as shown on page 1 Unless otherwise stated the information in this manual ap...

Страница 9: ...eatures as noted in this product manual 2 1 1 Electromagnetic compatibility The drive as delivered is designed for system integration and installation into a suitable enclosure prior to use The drive...

Страница 10: ...C If these drives have the Korean Communications Commission KCC logo they comply with KN22 KN 24 and KN61000 Taiwanese BSMI If this model has the Taiwanese certification mark then it complies with Chi...

Страница 11: ...3068 SAS Interface Manual Seagate part number 100293071 ANSI SAS Documents SFF 8223 2 5 Drive Form Factor with Serial Connector SFF 8460 HSS Backplane Design Guidelines SFF 8470 Multi Lane Copper Conn...

Страница 12: ...t the outermost radius of the media to eliminate the possibility of destroying or degrading data by landing in the data zone The heads automatically go to the ramp load unload when power is removed fr...

Страница 13: ...prietary protective layer for improved durability and environmental protection 3 3 PERFORMANCE Programmable multi segmentable cache buffer 600MB s maximum instantaneous data transfers 10K RPM spindle...

Страница 14: ...ber 100293071 A value of zero in the Number of Blocks field indicates that the drive will not change the capacity it is currently formatted to have A number other than zero and less than the maximum n...

Страница 15: ...verify 123 Execution time measured from receipt of the last byte of the Command Descriptor Block CDB to the request for a Status Byte Transfer to the Initiator excluding connect disconnect When changi...

Страница 16: ...using the Mode Select command however in actual operation the prefetch feature overlaps cache operation somewhat as described in sections 4 5 1 and 4 5 2 All default cache and prefetch mode parameter...

Страница 17: ...ing written into when the end of the segment is reached the data is written into the beginning of the same cache segment overwriting the data that was written there at the beginning of the operation h...

Страница 18: ...tions but not caused by the read If an unrecoverable data error is detected a MEDIUM ERROR 03h in the Sense Key will be reported Multiple unrecoverable data errors resulting from the same cause are tr...

Страница 19: ...t attempt fails or any time the drive looses sync the drive initiated link reset The drive will initiate link reset once per second but alternates between port A and B Therefore each port will attempt...

Страница 20: ...acceptable level To determine rate error events are logged and compared to the number of total operations for a given attribute The interval defines the number of operations over which to measure the...

Страница 21: ...here are two test coverage options implemented in DST 1 Extended test 2 Short test The most thorough option is the extended test that performs various tests on the drive and scans every logical block...

Страница 22: ...hort test or 010b for the extended test in bytes 1 bits 5 6 and 7 5 2 6 2 3 Short and extended tests DST has two testing options 1 short 2 extended These testing options are described in the following...

Страница 23: ...e message to abort the diagnostic To abort a DST executing in background mode use the abort code in the DST Function Code field This will cause a 01 self test aborted by the application client code to...

Страница 24: ...t spinning PowerChoiceTM can be invoked using one of these two methods Power Condition mode page method Enable and initialize the idle condition timers and or the standby condition timers The timer va...

Страница 25: ...page 0x1A Idle conditions enabled disabled Idle condition timer values 100ms increments default saved current changeable Power Condition Vital Product Data VPD Page VPD page 0x8A Supported power condi...

Страница 26: ...e Notify Spinup primitive 5 See paragraph 6 3 1 Conducted noise immunity Specified voltage tolerance includes noise and transient response 6 Operating condition is defined as random 8 block reads 7 Du...

Страница 27: ...5 No terminator power 6 3 1 Conducted noise immunity Noise is specified as a periodic and random distribution of frequencies covering a defined frequency range Maximum allowed noise values given belo...

Страница 28: ...tical axis To calculate BTUs per hour multiply watts by 3 4123 Figure 2 1200GB at 3Gb DC current and power vs input output operations per second 1200GB models in 6Gb operation Typical power dissipatio...

Страница 29: ...d operation at case temperatures beyond the rated MTBF temperature will degrade the drive MTBF and reduce product reliability Air flow may be required to achieve consistent nominal case temperature va...

Страница 30: ...newave Shock may be applied in the X Y or Z axis Shock is not to be repeated more than once every 2 seconds b Non operating The limits of non operating shock shall apply to all conditions of handling...

Страница 31: ...s chlorine and nitric oxide classes G and H per ASTM B845 However this accelerated testing cannot duplicate every potential application environment Users should use caution exposing any electronic com...

Страница 32: ...or detailed mounting configuration dimensions See Section 10 3 Drive mounting Note These dimensions conform to the Small Form Factor Standard documented in SFF 8201 and SFF 8223 found at www sffcommit...

Страница 33: ...modules tested National Voluntary Laboratory Accreditation Program NVLAP accredited laboratories perform cryptographic module compliance conformance testing Seagate Enterprise SED The SEDs referenced...

Страница 34: ...em The DEK is itself encrypted when it is stored on the media and when it is in volatile temporary storage DRAM external to the encryption engine A unique data encryption key is used for each of the d...

Страница 35: ...is unlocked 8 5 DATA BANDS When shipped from the factory the drive is configured with a single data band called Band 0 also known as the Global Data Band which comprises LBA 0 through LBA max The host...

Страница 36: ...nd a commensurate increase of about 150mW in power consumption There is no additional drain on the 12V supply See the tables in Section 6 3 for power requirements on the standard non SED drive models...

Страница 37: ...e drive if programmed to do so performs error recovery procedures to attempt to recover the data The error recovery procedures used depend on the options previously set in the Error Recovery Parameter...

Страница 38: ...or will be reported 9 3 SAS SYSTEM ERRORS Information on the reporting of operational errors or faults across the interface is given in the SAS Interface Manual The SSP Response returns information to...

Страница 39: ...or to returning to service host initiated commands Overhead associated with a return to host servicing activity from BMS only impacts the first command that interrupted BMS this results in a typical d...

Страница 40: ...smitted at LBA boundaries across the interface if RDPROTECT and WRTPROTECT bits are nonzero values Type 2 does allow the use of 10 and 16 byte commands with zero values in the RDPROTECT and WRTPROTECT...

Страница 41: ...ctors Power is supplied through the SAS connector The drive is shipped from the factory low level formatted in 512 byte logical blocks Reformat the drive only if a different logical block size needs t...

Страница 42: ...stiffness where K is the mounting surface stiffness units in lb in or N mm and X is the out of plane surface distortion units in inches or millimeters The out of plane distortion X is determined by de...

Страница 43: ...the same or different SCSI domains Each drive port has a unique SAS address The two ports have the capability of independent port clocking e g both ports can run at 6Gb s or the first port can run at...

Страница 44: ...te Code page C1h Y Device Behavior page C3h Y Device Identification page 83h Y Extended Inquiry Data page 86h Y Firmware Numbers page C0h Y Jumper Settings page C2h Y Mode Page policy page 87h N Power...

Страница 45: ...age 1Ch Y Background Scan mode subpage 01h Y Notch and Partition Page 0Ch N Protocol Specific Port page 19h Y Power Condition page 1Ah Y Rigid Disk Drive Geometry page 04h Y Unit Attention page 00h Y...

Страница 46: ...ocol Out B5h Y SED models only Seek 6 0Bh Y Seek 10 2Bh Y Send Diagnostics 1Dh Y Rebuild Assist page 42h Y Supported Diagnostics pages 00h Y Translate page 40h Y Start Unit Stop Unit spindle ceases ro...

Страница 47: ...Support is available on special request 5 Approximately 1 5 increase in time to complete this command for a SED drive versus a non SED drive of the same capacity Write Buffer modes 0 2 supported 3Bh...

Страница 48: ...0 32 Copyright 112 127 30 31 32 20 53 65 61 67 61 74 65 20 41 6C 6C 20 notice 128 143 72 69 67 68 74 73 20 72 65 73 65 72 76 65 64 20 Copyright year changes with actual year SCSI Revision support See...

Страница 49: ...ion on the media prior to shipping 3 Current values Current values are volatile values being used by the drive to control its operation A Mode Select command can be used to change the values identifie...

Страница 50: ...0 00 00 00 00 00 00 00 DEF 87 0a 00 14 ff 00 00 00 00 00 ff ff CHG 87 0a 0f ff 00 00 00 00 00 00 ff ff DEF 88 12 14 00 ff ff 00 00 ff ff ff ff 80 20 00 00 00 00 00 00 CHG 88 12 a5 00 00 00 ff ff ff ff...

Страница 51: ...are provided in the SAS Interface Manual Figure 10 Physical interface Table 8 Miscellaneous features Supported Feature or condition N Automatic contingent allegiance N Asynchronous event notification...

Страница 52: ...SEAGATE ENTERPRISE PERFORMANCE 10K HDD V7 PRODUCT MANUAL REV C 46 Figure 11 SAS device plug dimensions...

Страница 53: ...SEAGATE ENTERPRISE PERFORMANCE 10K HDD V7 PRODUCT MANUAL REV C 47 Figure 12 SAS device plug dimensions detail...

Страница 54: ...a backpanel or accept cables 11 4 5 Pin descriptions This section provides a pin out of the SAS device and a description of the functions provided by the pins Table 10 SAS pin descriptions Pin Signal...

Страница 55: ...mon ground pins The supply current and return current must be distributed as evenly as possible among the pins Current to the drive through the long power pins may be limited by the system to reduce i...

Страница 56: ...ransmitted during the SNW 3 training gap The DFE circuit can derive an optimal equalization characteristic to compensate for many of the receive losses in the system 2 A Feed Forward Equalizer FFE opt...

Страница 57: ...er track 9 C cache operation 10 cache segments 11 caching write data 11 Canadian Department of Communications 3 capacity unformatted 9 CBC 28 CE Marking 4 check condition status 45 China RoHS directiv...

Страница 58: ...und shift noise 49 grounding 36 H HDA 35 36 head and disk assembly See HDA heads read write data 9 heat removal 35 heat source 35 host equipment 36 hot plugging the drive 13 humidity 23 humidity limit...

Страница 59: ...er inch 9 peak operating current 20 peak to peak measurements 21 performance characteristics 9 detailed 9 general 9 performance highlights 7 physical damage 25 physical interface 45 physical specifica...

Страница 60: ...P 1 in Mode Select command 45 SNW 3 training gap 50 Specification 50 spindle brake 6 standards 3 Standby1 18 Standby2 18 START STOP UNIT command 18 start stop time 10 surface stiffness allowable for n...

Страница 61: ...nited States 408 658 1000 ASIA PACIFIC Seagate Singapore International Headquarters Pte Ltd 7000 Ang Mo Kio Avenue 5 Singapore 569877 65 6485 3888 EUROPE MIDDLE EAST AND AFRICA Seagate Technology SAS...

Отзывы: