Figure 14.
Recommended mounting
Note.
Image is for reference only, may not represent actual drive.
6.5.4.2
Vibration
a. Operating—normal
The drive as installed for normal operation, shall comply with the complete specified performance while subjected to con-
tinuous vibration not exceeding
5-500 Hz @ 0.5 G (zero to peak)
Vibration may be applied in the X, Y, or Z axis.
Operating normal translational random flat profile
10 - 500 Hz (translational random flat profile)
0.5 GRMS
b. Operating—abnormal
Equipment as installed for normal operation shall not incur physical damage while subjected to periodic vibration not
exceeding:
15 minutes of duration at major resonant frequency
5-500 Hz @ 0.75 G (X, Y, or Z axis)
Vibration occurring at these levels may degrade operational performance during the abnormal vibration period. Specified
operational performance will continue when normal operating vibration levels are resumed. This assumes system recov-
ery routines are available.
Operating abnormal translational random flat profile
10 - 500 Hz (translational random flat profile)