background image

Seagate Nytro XF1230 SATA SSD Product Manual, Rev. H

19 

www.Seagate.com

SMART Support

6.2

SMART Attributes

The Nytro XF1230 supports the SMART attributes shown in the following table.

Table 16 SMART Attributes

ID

Attribute ID

Description

1

Raw Read Error Rate

Rate of hardware read errors that occurred when 
reading data from a device

5

Retired Block count

Count of number of blocks that have been 
reallocated, excluding pending sectors

9

Power on hours

The time accumulated while the power is on and 
operating

12

Power Cycle Count

Count of number of Power Cycles, excluding power 
mode commands

174

Unexpected Power Loss Count

Number of Issue on Unexpected Power Loss

175

Program Fail Count (Worst Case 
Component per die)

Maximum number of Program Error Events per die

176

Erase Fail Count (Worst Case 
Component per die)

Maximum number of Erase Error Events per die

177

Endurance Limit Met

Indicates the number of NAND wear

178

Used Reserved Block Count (Worst 
Case Component)

Number of used reserved blocks

179

Used Reserved Block Count (SSD Total)

Number of used reserved blocks in SSD

180

End to End Error Detection / Correction 
Rate

Number of error detection of the data path between 
host and NAND in SSD during last power-on

181

Program Fail Count

Number of Error Events on Program (Lifetime)

182

Erase Fail Count

Number of Error Events on Erase (Lifetime)

183

SATA Downshift Count

Number of times that SATA interface speed reduced

184

End to End Error Detection Count

Number of error detection of the data path between 
host and NAND in SSD of lifetime

187

Reported Uncorrectable Errors

Uncorrectable Error Count

188

Command Timeout Count

Number of total uncompleted commands

189

SSD Health Flags

Indicates PLP health status and Thermal Throttling 
status

190

SATA Error Counter

Number of encountered SATA error

194

Temperature (Celsius)

Temperature of the SSD

195

ECC On the Fly Rate

Hardware read error rate that occurred when reading 
data

199

Ultra DMA CRC Error Count

Number of Ultra DMA CRC error count (Lifetime)

201

Read Error Rate

Number of soft read errors (Count of UECC Error)

204

Soft ECC Correction Rate

Count of errors corrected by software ECC[citation 
needed]

231

SSD Life Left (%)

Indicates the approximate SSD life left, in terms of 
program/erase cycles or Flash blocks currently 
available for use.

234

Lifetime NAND programs in GB

Lifetime NAND programs in GB

Содержание Nytro XF1230-1A0240

Страница 1: ...Seagate Nytro XF1230 SATA SSD Product Manual XF1230 1A0240 XF1230 1A0480 XF1230 1A0960 XF1230 1A1920 100797573 Rev H October 2017...

Страница 2: ...ent and report a lower capacity In addition some of the listed capacity is used for formatting and other functions and thus will not be available for data storage Actual quantities will vary based on...

Страница 3: ...pported ATA Command List 16 5 1 ATA Feature Set 16 5 2 ATA Command Description 16 5 3 Security 17 5 3 1 Password Loss 17 6 SMART Support 18 6 1 SMART Command Set 18 6 2 SMART Attributes 19 6 3 SMART T...

Страница 4: ...Seagate Nytro XF1230 SATA SSD Product Manual Rev H 4 7 2 1 2 Substances of Very High Concern SVHC 24 7 2 2 China Requirements China RoHS 2 24 7 2 3 Taiwan Requirements Taiwan RoHS 25 7 3 Reference Doc...

Страница 5: ...m contacts Available services include Presales Technical support Global Support Services telephone numbers business hours Authorized Service Centers For information regarding Warranty Support visit ht...

Страница 6: ...im support Latency Read 140 s Typ Write 60 s Typ Latency measured with transfer size 4 KB and queue depth of 1 on a random workload and based on high density 1920 GB NAND 16 nm Performance Random Sust...

Страница 7: ...d data path protection Shock Operating 1500G duration 0 5ms Non Operating 1500G duration 0 5ms Temperature Range Operating 0 C to 70 C Temperature Sensor SMART Attribute ID 194 Vibration Operating 20...

Страница 8: ...riations may affect measured results MB s 1 000 000 bytes second Table 2 Nytro XF1230 Card Models Device Name Model Names Usable Capacity LBAs Nytro XF1230 XF1230 1A0240 240 GB 468 862 128 Nytro XF123...

Страница 9: ...n Shock may be applied in the X Y or Z axis Shock must not be repeated more than once every 2 seconds Table 5 Operating Voltage 240 GB 480 GB 960 GB 1920 GB Operating Voltage range Inrush Current 5 V...

Страница 10: ...of handling and transportation This includes both isolated drive and integrated drives Vibration may be applied in the X Y or Z axis 2 5 Reliability 2 6 Endurance NOTE Information on endurance 1 DWPD...

Страница 11: ...Rev H 11 www Seagate com Mechanical Information 3 Mechanical Information 3 1 Dimensions and Weight Weight 0 187 lbs 85 g Height Maximum 7 mm Width 69 85 0 25 Length 100 0 25 NOTE All dimensions are in...

Страница 12: ...o XF1230 SATA SSD Product Manual Rev H 12 www Seagate com Pin and Signal Descriptions 4 Pin and Signal Descriptions 4 1 Serial ATA Interface Connector Figure 2 Connector Physical Dimension and Connect...

Страница 13: ...2 5 inch connector supports built in latching capability 4 3 Connector Pin Signal Definitions NOTE Key and spacing separate the signal and power segments Table 11 Serial ATA Connector Pin Signal Defin...

Страница 14: ...for efficient integration into current and future IC manufacturing processes The signal is not suitable for directly driving an LED and is first buffered using a circuit external to the device before...

Страница 15: ...Seagate Nytro XF1230 SATA SSD Product Manual Rev H 15 www Seagate com Pin and Signal Descriptions Figure 4 Circuit of SSD Activity LED indication...

Страница 16: ...Hex Command Code Hex CHECK POWER MODE E5h SMART DISABLE OPERATION B0h D9h DATA SET MANAGEMENT 06h SMART ENABLE DISABLE B0h D2h DOWNLOAD MICROCODE 92h SMART ENABLE OPERATION B0h D8h EXECUTE DEVICE DIA...

Страница 17: ...ay to access the device READ SECTOR S 20h WRITE MULTIPLE C5h READ SECTOR S EXT 24h WRITE MULTIPLE EXT 39h READ SECTOR S W O RETRY 21h WRITE MULTIPLE FUA EXT CEh READ VERIFY SECTOR S 40h WRITE SECTOR S...

Страница 18: ...IATE 00h Execute SMART Off Line routine 01h Execute SMART Short Self test routine Off Line 02h Execute SMART Extended Self test routine Off Line 03h Execute SMART Conveyance self test routine in off l...

Страница 19: ...180 End to End Error Detection Correction Rate Number of error detection of the data path between host and NAND in SSD during last power on 181 Program Fail Count Number of Error Events on Program Lif...

Страница 20: ...ondition is also checked during drive self tests 241 Lifetime Writes From The Host in GB Track the number of user data in GB written by the host 242 Lifetime Reads From The Host in GB Track the number...

Страница 21: ...oltage Directive LVD 2014 35 EU Seagate drives are tested in representative end user systems Although CE marked Seagate drives comply with all relevant regulatory requirements and standards for the dr...

Страница 22: ...into the OEM s finished system level product by an end user The Customer Kits are considered devices under Morocco s Order of the Minister of Industry Trade Investment and Digital Economy No 2574 14...

Страница 23: ...e from the Superintendent of Documents U S Government Printing Office Washington DC 20402 Refer to publication number 004 000 00345 4 7 1 9 Japan VCCI This is a Class B product based on the standard o...

Страница 24: ...our Seagate Sales Representative 7 2 2 China Requirements China RoHS 2 China RoHS 2 refers to the Ministry of Industry and Information Technology Order No 32 effective July 1 2016 titled Management Me...

Страница 25: ...ument this document takes precedence Table 18 Taiwan Restricted Substances SSD Equipment Name Hard Disk Device SSD Type Designation Internal Use Only Unit Restricted Substance and its chemical symbol...

Страница 26: ...ited States 408 658 1000 ASIA PACIFIC Seagate Singapore International Headquarters Pte Ltd 7000 Ang Mo Kio Avenue 5 Singapore 569877 65 6485 3888 EUROPE MIDDLE EAST AND AFRICA Seagate Technology SAS 1...