Seek power (typical)

1.3W

Read/write power (typical)

Read: 1.25W; Write: 1.65W

Idle mode, low power (typical)

0.47W

Standby mode

0.12W (typical)***

Sleep mode

0.12W (typical)***

Voltage tolerance (including noise)

+5V ± 5%

Ambient temperature 

0° to 60°C (operating), –40° to 70°C (nonoperating)

Temperature gradient

 

(°C per hour max)

20°C (operating)

 

35°C (nonoperating)

Relative humidity

5% to 95% (operating)

 

5% to 95% (nonoperating)

Relative humidity gradient

30% per hour max

Wet bulb temperature

 

(°C max)

37.7 (operating)

 

40 (nonoperating)

Altitude, operating

–304.8 m to 3048 m (–1000 ft to 10,000

 

ft)

Altitude, nonoperating 

 

(meters below mean sea level, max)

–304.8 m to 12,192 m (–1000 ft to 40,000

 

ft)

Shock, operating (Gs max at 2ms)

350

Shock, nonoperating (Gs max at 1ms)

1000

Shock, nonoperating (Gs max at 0.5ms)

1000

Vibration, operating

1.0 G (0 to peak, 5–500 Hz)

Vibration, nonoperating

5.0 Gs (0 to peak, 5–500 Hz)

Drive acoustics, sound power (bels)

   Idle**

2.3 (typical)

 

2.5 (max)

  Seek

2.4 (typical)

 

2.6 (max)

Nonrecoverable read errors

1 per 10

14

 bits read

Annualized Failure Rate (AFR)

0.48%

Load/Unload (U/UL) cycles

 

 

25°C, 50% relative humidity

 

 

 

32°C, 80% relative humidity 

 

5°C, 80% relative humidity 

 

5°C, 10% relative humidity 

 

55°C, 16% relative humidity 

 

 

600,000 software-controlled power on/off cycles

 

50,000 hard power on/off cycles

 

 

600,000 software-controlled power on/off cycles

 

50,000 hard power on/off cycles

 

Warranty

To determine the warranty for a specific drive, use a web browser to access the

 

following web page:

 

http://www.seagate.com/www/en-us/support/warranty_&_returns_assistance

 

You will be asked to provide the drive serial number, model number (or part number)

 

and country of purchase. After submitting this information, the system will display the

 

 warranty information for your drive.

Supports Hotplug operation per

 

Serial ATA Revision 2.6 specification

Yes (requires COMRESET from host after a hotplug event)

Table 1: 

Drive specifications for 640, 500 and 400GB models

Drive specification

ST9640322AS

ST9640320AS

ST9500320AS

ST9400321AS

Содержание MOMENTUS ST9160316AS

Страница 1: ...Product Manual Momentus 100589392 Rev D November 2010 512 byte sector models ST9640320AS ST9500320AS ST9320310AS ST9250310AS ST9160316AS 4096 byte sector models ST9640322AS ST9400321AS ST9320312AS...

Страница 2: ...is publication may be reproduced in any form without written permission of Seagate Technology LLC Call 877 PUB TEK1 877 782 8351 to request permission One gigabyte or GB equals one billion bytes and o...

Страница 3: ...Humidity 13 3 10 4 Altitude 13 3 10 5 Shock 14 3 10 6 Vibration 14 3 11 Acoustics 15 3 12 Electromagnetic immunity 15 3 13 Reliability 16 3 14 Agency certification 16 3 14 1 Safety certification 16 3...

Страница 4: ...ii Momentus Product Manual Rev D...

Страница 5: ...nual Rev D iii List of Figures Figure 1 Typical 5V only startup and operation current profile 11 Figure 2 Serial ATA connectors 20 Figure 3 Attaching SATA cabling 20 Figure 4 Mounting dimensions top s...

Страница 6: ......

Страница 7: ...ales Technical support Global Support Services telephone numbers business hours Authorized Service Centers For information regarding Warranty Support visit http www seagate com www en us support warra...

Страница 8: ...algorithms Native Command Queuing NCQ with command ordering Full track multiple sector transfer capability without local processor intervention 1000 Gs nonoperating shock and 350 Gs of operating shoc...

Страница 9: ...system views the two devices as if they were both masters on two separate ports This essentially means both drives behave as if they are Device 0 master devices Note The host adapter may optionally e...

Страница 10: ...6 773 168 781 422 768 bytes per physical sector 4096 512 512 4096 Physical read write heads 4 Discs 2 Cache MB 8 Recording density in BPI bits in avg 1560k Track density TPI tracks in avg 325k Areal d...

Страница 11: ...12 192 m 1000 ft to 40 000 ft Shock operating Gs max at 2ms 350 Shock nonoperating Gs max at 1ms 1000 Shock nonoperating Gs max at 0 5ms 1000 Vibration operating 1 0 G 0 to peak 5 500 Hz Vibration non...

Страница 12: ...3 951 0 008 0 010in Weight 100 g 0 220 lb Power on to ready sec typical 3 6 Power on to ready sec max 4 5 Standby to ready sec typical 2 5 Standby to ready sec max 3 5 Track to track seek time read ms...

Страница 13: ...d errors 1 per 1014 bits read Annualized Failure Rate AFR 0 48 Load Unload U UL cycles 25 C 50 relative humidity 32 C 80 relative humidity 5 C 80 relative humidity 5 C 10 relative humidity 55 C 16 rel...

Страница 14: ...ing these drives in LBA mode all blocks sectors are consecutively numbered from 0 to n 1 where n is the number of guaranteed logical blocks as defined above See Section 5 3 1 Identify Device command w...

Страница 15: ...All times are measured using drive diagnostics The specifications in the table below are defined as follows Track to track seek time is an average of all possible single track seeks in both directions...

Страница 16: ...power is measured based on three random seek operations every 100ms This mode is not typical Read write power and current Read write power is measured with the heads on track based on three 63 sector...

Страница 17: ...de Server family of drives 3 9 3 Conducted noise Input noise ripple is measured at the host system power supply across an equivalent 15 ohm resistive load on the 5V line Using 5V power the drive is ex...

Страница 18: ...s is necessary Sleep mode The drive enters Sleep mode after receiving a Sleep command from the host In Sleep mode the drive buffer is in Self Refresh Low Power mode the heads are parked and the spindl...

Страница 19: ...C per hour 68 F per hour max without condensation Nonoperating 35 C per hour 95 F per hour max without condensation 3 10 3 Humidity 3 10 3 1 Relative humidity Operating 5 to 95 noncondensing 30 per ho...

Страница 20: ...quently put into operation is 1000 Gs based on a nonrepetitive half sine shock pulse of 1ms duration 3 10 6 Vibration All vibration specifications assume that the drive is mounted securely with the in...

Страница 21: ...iven by ISO 389 7 Tf curve minus 10dB at all frequencies 3 12 Electromagnetic immunity When properly installed in a representative host system the drive operates without errors or degradation in perfo...

Страница 22: ...3 14 1 Safety certification These products are certified to meet the requirements of UL60950 1 CSA60950 1 and EN60950 and so marked as to the certify agency 3 14 2 Electromagnetic compatibility Hard d...

Страница 23: ...described above to ensure that the total assembly enclosure disc drive motherboard power supply etc does comply with the limits for a Class B computing device pursuant to Subpart J Part 15 of the FCC...

Страница 24: ...t at the homogenous material level is over the threshold defined by the China RoHS MCV Standard 3 16 Corrosive environment Seagate electronic drive components pass accelerated corrosion testing equiva...

Страница 25: ...ling the drive put on a grounded wrist strap or ground yourself frequently by touching the metal chassis of a computer that is plugged into a grounded outlet Wear a grounded wrist strap throughout the...

Страница 26: ...2 Serial ATA connectors 4 3 Serial ATA cables and connectors The Serial ATA interface cable consists of four conductors in two differential pairs plus three ground connec tions The cable size may be 3...

Страница 27: ...se only M3 UNC mounting screws Do not overtighten the mounting screws Maximum torque 4 0 in lb 0 4519 N m Four 4 threads 0 080in 2 032 mm minimum screw engagement recommended Avoid excessive drive dis...

Страница 28: ...22 Momentus Product Manual Rev D Measurements shown in Figure 4 are in inches Figure 4 Mounting dimensions top side and end view...

Страница 29: ...drives incorporate connectors which enable you to hot plug these drives in accordance with the Serial ATA High Speed Serialized AT Attachment specification revision 2 0 This specification can be down...

Страница 30: ...d mate backplane configuration 4 All used voltage pins Vx must be terminated Power P1 V33 3 3V power P2 V33 3 3V power P3 V33 3 3V power pre charge 2nd mate P4 Ground 1st mate P5 Ground 2nd mate P6 Gr...

Страница 31: ...90h Flush Cache E7h Flush Cache Extended EAh Identify Device ECh Initialize Device Parameters 91h Read Buffer E4h Read DMA C8h Read DMA Extended 25h Read DMA without Retries C9h Read Long with Retrie...

Страница 32: ...Write Attribute Values B0h E1h S M A R T Write Log Sector B0h D6h Write Buffer E8h Write DMA CAh Write DMA Extended 35h Write DMA without Retries CBh Write Long with Retries 32h Write Long without Ret...

Страница 33: ...mber of logical cylinders 16 383 2 ATA reserved 0000H 3 Number of logical heads 16 4 Retired 0000H 5 Retired 0000H 6 Number of logical sectors per logical track 63 003FH 7 9 Retired 0000H 10 19 Serial...

Страница 34: ...fer cycle time per word 120 nsec 0078H 67 Minimum PIO cycle time without IORDY flow control 240 nsec 00F0H 68 Minimum PIO cycle time with IORDY flow control 120 nsec 0078H 69 74 ATA reserved 0000H 75...

Страница 35: ...s currently active 11 Ultra DMA mode 3 is currently active 12 Ultra DMA mode 4 is currently active 13 Ultra DMA mode 5 is currently active 14 Ultra DMA mode 6 is currently active Bit Word 93 13 1 80 c...

Страница 36: ...di cated above Table 9 Set Features command values 02H Enable write cache default 03H Set transfer mode based on value in Sector Count register Sector Count register values 00H Set PIO mode to default...

Страница 37: ...urns The diagnostic software ships with all new drives and is also available at http seatools seagate com This drive is shipped with S M A R T features disabled You must have a recent BIOS or software...

Страница 38: ...32 Momentus Product Manual Rev D...

Страница 39: ...6 cycles 16 Cylinders 8 D data transfer rates 2 DC power 10 Default logical geometry 8 density 4 6 Device Configuration Freeze Lock 25 Device Configuration Restore 25 Device Configuration Set 25 Diagn...

Страница 40: ...Nonoperating shock 14 Nonoperating vibration 14 Nonrecoverable read errors 5 7 nonrecoverable read errors 16 O Operating shock 14 Operating vibration 14 P Physical characteristics 9 Physical organizat...

Страница 41: ...ess 25 Set Multiple Mode 25 Shock 14 Shock nonoperating 5 7 Shock operating 5 6 7 single track seeks 9 Sleep 10 26 Sleep mode 5 6 12 sound power 5 7 Specification summary table 4 Spindle speed 4 6 9 S...

Страница 42: ...36 Momentus Product Manual Rev D...

Страница 43: ......

Страница 44: ...Seagate Technology LLC 920 Disc Drive Scotts Valley California 95066 4544 USA Publication Number 100589392 Rev D...

Отзывы: