Spinpoint M8U-Internal Product Manual REV 3.4
100
INSTALLATION
Table 6-39: Descriptor Code Definition
Table 6-40: Formattable Capacity Descriptor
The
Number of Blocks
field indicates the maximum (or fixed) number of addressable blocks for the given
capacity descriptor.
The
Block Length
specifies the length in bytes of each logical block for the given capacity descriptor.
6.5.6 WRITE (10) Command (2Ah)
The WRITE (10) command (Table 6-41) requests that the UFI device write the data transferred by the host to
the medium.
Table 6-41: WRITE (10) Command
DPO:
This bit should be set to zero.
FUA:
This bit should be set to zero.
RelAdr
: This bit should be set to zero.
Содержание M8U-Internal SpinPoint
Страница 1: ...M8U Internal Product Manual 2 5 Hard Disk Drive May 12 2015 Rev 3 4 PM M8U USB2 0 100698037 Rev F ...
Страница 19: ...Spinpoint M8U Internal Product Manual REV 3 4 11 SPECIFICATIONS Figure 3 1 Measurement Position ...
Страница 30: ...Spinpoint M8U Internal Product Manual REV 3 4 22 INSTALLATION Figure 5 1 Exploded Mechanical View ...