Lyve Rack R1 Installation Guide
35
Figure 17: Ops panel - Only the Power ON LED should be lit.
Figure 18: Drawer LED panels
(two per drawer - left and right). Sideplane
OK/Power Good LED should be lit
8.2 | Switch ON server
After the 5U84 storage enclosure is switched ON and the LEDs show normal operation, switch on
server A and then server B.
Figure 19: Different components of the server control panel present at the front
Table 9: Server control panel component description
Item number
Name
Description
1
Power button
The main power switch applies or removes primary power
from the power supply to the server but maintains standby
power.
2
Reset button
Reboots the system. Do not use unless requested by
support.
3
Power LED
Indicates power is being supplied to the system power
supply units. This LED is illuminated when the system is
operating normally.
4
HDD
Indicates activity on the storage drive when flashing.