62
Installation
To route power cords from the power supply units:
1.
Select both power cords from the packaging, remove the cable ties, and connect a right-angle power cord connector
to each PSU.
2.
Move the CMA bracket assembly aside to access the cable capture clip on the chassis.
3.
Loosen the captive screw on cable capture clip and then raise the clip on its hinge.
Figure 50 Location of cable capture clip release screw
4.
Route the outer power cord just inside the outer fan and up to the clip, allowing a minimum of slack.
5.
Route the inner power cord just inside the third fan and up to the clip, allowing a minimum of slack.
Figure 51 Power cord routing up to cable capture clip
Required equipment
Qty
Identification
CMA bracket assembly
1
N/A
T10 Torx driver, 6-in length
1
N/A
Power cords
2
N/A
M3 low-profile screw, 5x2.75-in length
1