Seagate Exos X18 SAS Product Manual, Rev. D
50
www.seagate.com
Interface requirements
Extent Reservation
N
Restore Elements and Rebuild
9Eh/19h
Y
Rezero Unit (6)
01h
Y
Sanitize
48h
Y
Block Erase
48h / 02h
N
Cryptographic Erase
48h / 03h
Y (SED only)
Overwrite
48h / 01h
Y
Sanitize Exit
48h / 1Fh
Y
Search Data Equal
31h
N
Search Data High
30h
N
Search Data Low
32h
N
Security Protocol In
A2h
Y (SED models only)
Security Protocol Out
B5h
Y (SED models only)
Seek (6)
0Bh
Y
Seek (10)
2Bh
Y
Send Diagnostics
1Dh
Y
Supported Diagnostics pages (00h)
Y
Translate page (40h)
Y
Set Identifying Information
A4h/06h
Y
Set Limits
33h
N
Set Timestamp
A4h/0Fh
Y
Start Unit/Stop Unit (spindle ceases rotating)
1Bh
Y
Synchronize Cache (10)
35h
Y
Synchronize Cache (16)
91h
Y
Test Unit Ready
00h
Y
Verify (10)
2Fh
Y
BYTCHK bit
Y
Verify (12)
AFh
N
Verify (16)
8Fh
Y
Verify (32)
7Fh/000Ah
Y
Write (6)
0Ah
Y
Write (10)
2Ah
Y
DPO bit
Y
FUA bit
Y
Write (12)
AAh
N
Write (16)
8Ah
Y
Write (32)
7Fh/000Bh
Y
Write and Verify (10)
2Eh
Y
DPO bit
Y
Write and Verify (12)
AEh
N
Write and Verify (16)
8Eh
Y
Table 8
Supported commands
Command name
Command code
Supported
[4]