C
ONSTELLATION
ES.1 SAS P
RODUCT
M
ANUAL
, R
EV
. G
21
Note.
See table notes on the next page.
[1]
Measured with average reading DC ammeter.
[2]
Instant12V current peaks will exceed these values.
[3]
Power supply at nominal voltage. N (number of drives tested) = 6, 35 Degrees C ambient.
[4]
For +12 V, a –10% tolerance is allowed during initial spindle start but must return to ±5% before reaching 7200 RPM. The ±5% must
be maintained after the drive signifies that its power-up sequence has been completed and that the drive is able to accept selection
by the host initiator.
[5]
See +12V current profile in Figure 3.
[6]
This condition occurs after OOB and Speed Negotiation completes but before the drive has received the Notify Spinup primitive.
[7]
See paragraph 6.3.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and transient response.
[8]
Operating condition is defined as random 8 block reads.
[9]
During idle, the drive heads are relocated every 60 seconds to a random location within the band from three-quarters to maximum
track.
Table 4
500GB drive (Standard & SED model) DC power requirements
Notes
3.0Gb mode
6.0Gb mode
(Amps)
(Amps)
Voltage
+5V
+12V [4]
+5V
+12V [4]
Regulation
[5]
±5%
±5% [2]
±5%
±5% [2]
Avg idle current DCX
[1] [7]
0.36
0.21
0.36
0.21
Advanced idle current
Idle_A
0.36
0.21
0.36
0.21
Idle_B
0.25
0.19
0.25
0.19
Idle_C/ Standby_Y
0.25
0.11
0.25
0.12
Standby_Z
0.25
0.02
0.26
0.02
Transition current
Idle_A - Active
0.62
1.48
0.64
1.42
Idle_B - Active
0.62
1.32
0.70
1.35
Idle_C - Active
0.66
2.04
0.84
2.05
Standby - Active
0.88
2.46
0.86
2.53
Maximum starting current
(peak DC) DC
3s
[5]
0.61
1.92
0.61
1.93
(peak AC) AC
3s
[5]
0.83
2.53
0.96
2.59
Delayed motor start (max) DC
3s
[1] [6]
0.44
0.02
0.44
0.02
Peak operating current (random read):
Typical DCX
[1] [6]
0.44
0.37
0.44
0.38
Maximum DC
3s
[1]
0.44
0.39
0.50
0.41
Maximum (peak) DC
3s
1.18
1.48
1.29
1.45
Peak operating current (random write)
Typical DCX
0.54
0.28
0.54
0.29
Maximum DC
3s
0.59
0.31
0.59
0.41
Maximum (peak) DC
3s
1.32
1.47
1.32
1.47
Peak operating current (sequential read)
Typical DCX
0.77
0.20
0.77
0.20
Maximum DC
3s
0.84
0.21
0.84
0.21
Maximum (peak) DC
3s
1.07
0.40
1.07
0.43
Peak operating current (sequential write)
Typical DCX
0.95
0.20
0.95
0.20
Maximum DC
3s
1.01
0.21
1.01
0.21
Maximum (peak) DC
3s
1.40
0.38
1.38
0.38