Constellation ES.1 SAS Product Manual, Rev. E
3
3.0
Applicable standards and reference documentation
The drives documented in this manual have been developed as system peripherals to the highest standards of
design and construction. The drives depends on host equipment to provide adequate power and environment
for optimum performance and compliance with applicable industry and governmental regulations. Special
attention must be given in the areas of safety, power distribution, shielding, audible noise control, and temper-
ature regulation. In particular, the drive must be securely mounted to guarantee the specified performance
characteristics. Mounting by bottom holes must meet the requirements of Section 11.3.
3.1
Standards
The Constellation ES.1 family complies with Seagate standards as noted in the appropriate sections of this
manual and the Seagate
SAS Interface Manual
, part number 100293071.
The drives are recognized in accordance with UL 60950-1 as tested by UL, CSA 60950-1 as tested by CSA,
and EN60950-1 as tested by TUV.
The security features of Self-Encrypting Drive models are based on the “TCG Storage Architecture Core Spec-
ification” and the “TCG Storage Workgroup Security Subsystem Class: Enterprise_A” specification with addi-
tional vendor-unique features as noted in this product manual.
3.1.1
Electromagnetic compatibility
The drive, as delivered, is designed for system integration and installation into a suitable enclosure prior to
use. The drive is supplied as a subassembly and is not subject to Subpart B of Part 15 of the FCC Rules and
Regulations nor the Radio Interference Regulations of the Canadian Department of Communications.
The design characteristics of the drive serve to minimize radiation when installed in an enclosure that provides
reasonable shielding. The drive is capable of meeting the Class B limits of the FCC Rules and Regulations of
the Canadian Department of Communications when properly packaged; however, it is the user’s responsibility
to assure that the drive meets the appropriate EMI requirements in their system. Shielded I/O cables may be
required if the enclosure does not provide adequate shielding. If the I/O cables are external to the enclosure,
shielded cables should be used, with the shields grounded to the enclosure and to the host controller.
3.1.1.1
Electromagnetic susceptibility
As a component assembly, the drive is not required to meet any susceptibility performance requirements. It is
the responsibility of those integrating the drive within their systems to perform those tests required and design
their system to ensure that equipment operating in the same system as the drive or external to the system
does not adversely affect the performance of the drive. See Table 2, DC power requirements.
Содержание Constellation Constellation ST4000NM0053
Страница 6: ...iv Constellation ES 1 SAS Product Manual Rev E ...
Страница 8: ...vi Constellation ES 1 SAS Product Manual Rev E ...
Страница 80: ...72 Constellation ES 1 SAS Product Manual Rev E ...
Страница 86: ...78 Constellation ES 1 SAS Product Manual Rev E ...
Страница 87: ......