Cheetah 10K.6 FC Product Manual, Rev. F
was written there at the beginning of the operation; however, the drive does not overwrite data that has not yet
been written to the medium.
If write caching is enabled (WCE=1), then the drive may return Good status on a write command after the data
has been transferred into the cache, but before the data has been written to the medium. If an error occurs
while writing the data to the medium, and Good status has already been returned, a deferred error will be gen-
erated.
The Synchronize Cache command may be used to force the drive to write all cached write data to the medium.
Upon completion of a Synchronize Cache command, all data received from previous write commands will have
been written to the medium.
Table 15 shows the mode default settings for the drive.
4.5.2
Prefetch operation
If the Prefetch feature is enabled, data in contiguous logical blocks on the disc immediately beyond that which
was requested by a Read command are retrieved and stored in the buffer for immediate transfer from the buffer
to the host on subsequent Read commands that request those logical blocks (this is true even if cache opera-
tion is disabled). Though the prefetch operation uses the buffer as a cache, finding the requested data in the
buffer is a prefetch hit, not a cache operation hit.
To enable Prefetch, use Mode Select page 08h, byte 12, bit 5 (Disable Read Ahead—DRA bit). DRA bit = 0
enables prefetch.
Since data that is prefetched replaces data already in some buffer segments, the host can limit the amount of
prefetch data to optimize system performance. The Max Prefetch field (bytes 8 and 9) limits the amount of
prefetch. The drive does not use the Prefetch Ceiling field (bytes 10 and 11).
During a prefetch operation, the drive crosses a cylinder boundary to fetch more data only if Mode parameters
page 08h, byte 2, bit 4 is set to 1 (Discontinuity—DISC bit).
When prefetch (read look-ahead) is enabled (enabled by DRA = 0), it operates under the control of ARLA
(Adaptive Read Look-Ahead). If the host uses software interleave, ARLA enables prefetch of contiguous blocks
from the disc when it senses that a prefetch hit will likely occur, even if two consecutive read operations were
not for physically contiguous blocks of data (e.g. “software interleave”). ARLA disables prefetch when it decides
that a prefetch hit will not likely occur. If the host is not using software interleave, and if two sequential read
operations are not for contiguous blocks of data, ARLA disables prefetch, but as long as sequential read oper-
ations request contiguous blocks of data, ARLA keeps prefetch enabled.
4.5.3
Optimizing cache performance for desktop and server applications
Desktop and server applications require different drive caching operations for optimal performance. This
means it is difficult to provide a single configuration that meets both of these needs. In a desktop environment,
you want to configure the cache to respond quickly to repetitive accesses of multiple small segments of data
without taking the time to “look ahead” to the next contiguous segments of data. In a server environment, you
want to configure the cache to provide large volumes of sequential data in a non-repetitive manner. In this
case, the ability of the cache to “look ahead” to the next contiguous segments of sequential data is a good
thing.
The Performance Mode (PM) bit controls the way the drive switches the cache buffer into different modes of
segmentation. In “server mode” (PM bit = 0), the drive can dynamically change the number of cache buffer seg-
ments as needed to optimize the performance, based on the command stream from the host. In “desktop
mode” (PM bit = 1), the number of segments is maintained at the value defined in Mode Page 8, Byte 13, at all
times. For additional information about the PM bit, refer to the Unit Attention Parameters page (00h) of the
Mode Sense command (1Ah) in the
Fibre Channel Interface Product Manual
, part number 77767496.
Содержание Cheetah 10K.6 FC ST336607FC
Страница 1: ...Cheetah 10K 6 FC Disc Drive ST3146807FC ST373307FC ST336607FC Product Manual Volume 1...
Страница 2: ......
Страница 3: ...Cheetah 10K 6 FC Disc Drive ST3146807FC ST373307FC ST336607FC Product Manual Volume 1...
Страница 6: ......
Страница 10: ......
Страница 12: ...2 Cheetah 10K 6 FC Product Manual Rev F...
Страница 18: ...8 Cheetah 10K 6 FC Product Manual Rev F...
Страница 38: ...28 Cheetah 10K 6 FC Product Manual Rev F Figure 14 Recommended mounting Z Y X Z Y X...
Страница 76: ...66 Cheetah 10K 6 FC Product Manual Rev F...
Страница 83: ......