background image

C

HEETAH 

15K.7 FC P

RODUCT 

M

ANUAL

, R

EV

. E

  23

  

   

Figure 2. 

Typical ST3450857FC current profiles

   

Figure 3. 

Typical ST3300657FC current profiles

Содержание Cheetah 100516225

Страница 1: ...etah 15K 7 FC 100516225 Rev E December 2012 Standard models ST3600057FC ST3450857FC ST3300657FC Self Encrypting Drive models ST3600957FC ST3450757FC ST3300557FC SED FIPS 140 2 models ST3600857FC ST345...

Страница 2: ...877 PUB TEK1 877 782 8351 to request permission When referring to drive capacity one gigabyte or GB equals one billion bytes and one terabyte or TB equals one trillion bytes Your computer s operating...

Страница 3: ...PERFORMANCE CHARACTERISTICS 10 4 2 1 Access time 10 4 2 2 Format command execution time minutes 11 4 2 3 General performance characteristics 11 4 3 START STOP TIME 11 4 4 PREFETCH MULTI SEGMENTED CACH...

Страница 4: ...8 5 DATA BANDS 33 8 6 CRYPTOGRAPHIC ERASE 33 8 7 AUTHENTICATED FIRMWARE DOWNLOAD 33 8 8 POWER REQUIREMENTS 33 8 9 SUPPORTED COMMANDS 33 9 0 DEFECT AND ERROR MANAGEMENT 34 9 1 DRIVE INTERNAL DEFECTS E...

Страница 5: ...TIONS 55 11 5 FC AL PHYSICAL INTERFACE 56 11 5 1 Physical characteristics 56 11 5 2 Connector requirements 57 11 5 3 Electrical description 57 11 5 4 Pin descriptions 58 11 5 5 FC AL transmitters and...

Страница 6: ...business hours Authorized Service Centers For information regarding Warranty Support visit http www seagate com support warranty and returns For information regarding data recovery services visit htt...

Страница 7: ...ormation in this manual applies to standard and Self Encrypting Drive models Note Previous generations of Seagate Self Encrypting Drive models were called Full Disk Encryption FDE models before a diff...

Страница 8: ...uct manual 2 1 1 Electromagnetic compatibility The drive as delivered is designed for system integration and installation into a suitable enclosure prior to use As such the drive is supplied as a suba...

Страница 9: ...dio Research Laboratory RRL Ministry of Information and Communication Republic of Korea Taiwanese BSMI If this model has two Chinese words meaning EMC certification followed by an eight digit identifi...

Страница 10: ...SCA 2 Connector with Bidirectional Enclosure Services Interface ANSI Small Computer System Interface SCSI Documents X3 131 1994 SCSI 2 X3 270 1996 SCSI 3 Architecture Model NCITS 305 199X SCSI 3 Encl...

Страница 11: ...s defined by the Trusted Computing Group see www trustedcomputinggroup org Note Never disassemble the HDA and do not attempt to service items in the sealed enclosure heads media actuator etc as this r...

Страница 12: ...frame sizes from 256 to 2 112 bytes Industry standard 3 5 inch low profile form factor dimensions Programmable logical block reallocation scheme Flawed logical block reallocation at format time Progr...

Страница 13: ...s current and future products will meet We recommend customers use this capacity in their project planning as it ensures a stable operating point with backward and forward compatibility from generatio...

Страница 14: ...ch are incorporated at the manufacturing facility during production or packaged before shipping Some of the options available are not an exhaustive list of possible options Other capacities can be ord...

Страница 15: ...2 37 1 49 2 37 Gbits sec max disk rotation speed 15k 15k 15k RPM Avg rotational latency 2 0 2 0 2 0 msec One Gbyte equals one billion bytes when referring to hard drive capacity Accessible capacity m...

Страница 16: ...t of the first logical block transfer to or from the host 1MB sec 1 000 000 bytes sec 4 3 START STOP TIME If the Motor Start option is disabled the drive becomes ready within 20 seconds after DC power...

Страница 17: ...or the moment That is the drive does not check in the buffer segments for the requested read data but goes directly to the medium to retrieve it The retrieved data merely passes through some buffer se...

Страница 18: ...mmand after the data has been transferred into the cache but before the data has been written to the medium If an error occurs while writing the data to the medium and Good status has already been ret...

Страница 19: ...s than 1 sector in error per 1016 bits transferred Unrecoverable Data Errors resulting from the same cause are treated as 1 error for that block 5 1 3 Seek errors A seek error is defined as a failure...

Страница 20: ...next device in the loop will continue to receive the output of the previous device to the newly inserted device If the bypass circuit is not present loop operation is temporarily disrupted until the...

Страница 21: ...T monitors the rate at which errors occur and signals a predictive failure if the rate of degraded errors increases to an unacceptable level To determine rate error events are logged and compared to...

Страница 22: ...nts The first trip point is set at 68 C which is the maximum temperature limit according to the drive specification The second trip point is user selectable using the Log Select command The reference...

Страница 23: ...e Not Ready condition is reported by the drive under the following conditions Motor will not spin Motor will not lock to speed Servo will not lock on track Drive cannot read configuration tables from...

Страница 24: ...e to appear in the self test results values log All other abort mechanisms will be reported as a 02 self test routine was interrupted by a reset condition 5 2 7 Product warranty Beginning on the date...

Страница 25: ...dditional drain on the 12V supply Table 2 ST3600057FC DC power requirements 2 Gbit 4 Gbit Notes Amps Amps Amps Amps Voltage 5V 12V 2 5V 12V 2 Regulation 5 5 5 2 5 5 2 Avg idle current DCX 1 7 0 39 0 8...

Страница 26: ...rrent loading for each supply voltage is not less than 1 2 of the maximum operating current shown 2 The 5V and 12V supplies should employ separate ground returns 3 Where power is provided to multiple...

Страница 27: ...ncing The drive protects against inadvertent writing during power up and down 6 2 3 Current profiles The 12V and 5V current profiles are shown in the following figures Note All times and currents are...

Страница 28: ...CHEETAH 15K 7 FC PRODUCT MANUAL REV E 23 Figure 2 Typical ST3450857FC current profiles Figure 3 Typical ST3300657FC current profiles...

Страница 29: ...o calculate BTUs per hour multiply watts by 3 4123 Figure 4 ST3600057FC DC current and power vs input output operations per second 450GB models Typical power dissipation under idle conditions in 4 Gbi...

Страница 30: ...typical random read operations refer to the following I O rate curve see Figure 4 Locate the typical I O rate for a drive in your system on the horizontal axis and read the corresponding 5 volt curren...

Страница 31: ...68 F 20 C per hour Air flow may be needed in the drive enclosure to keep within this range see Section 8 3 Operation at HDA case temperatures outside this range may adversely affect the drives abilit...

Страница 32: ...Shock occurring at abnormal levels may promote degraded operational performance during the abnormal shock period Specified operational performance will continue when normal operating shock levels resu...

Страница 33: ...CHEETAH 15K 7 FC PRODUCT MANUAL REV E 28 Z Y X Z Y X Figure 8 Recommended mounting...

Страница 34: ...ation Sound power while operating shall be 3 8 bels typical when measured to ISO 7779 specification There will not be any discrete tones more than 10 dB above the masking noise on typical drives when...

Страница 35: ...ad engagement of 0 12 in 3 05 mm Notes 1 Inches A B C D E F H J K L M N P R S T U 26 10 147 00 101 60 95 25 3 18 44 45 28 50 101 60 6 35 41 60 4 60 1 02 41 28 41 10 7 00 0 38 0 38 1 028 5 787 4 000 3...

Страница 36: ...ve their modules tested National Voluntary Laboratory Accreditation Program NVLAP accredited laboratories perform cryptographic module compliance conformance testing Seagate Enterprise SED The SED dri...

Страница 37: ...engine A unique data encryption key is used for each of the drive s possible16 data bands see Section 8 5 8 2 CONTROLLED ACCESS The drive has two security partitions SPs called the Admin SP and the L...

Страница 38: ...daries 8 6 CRYPTOGRAPHIC ERASE A significant feature of SEDs is the ability to perform a cryptographic erase This involves the host telling the drive to change the data encryption key for a particular...

Страница 39: ...tion the drive if programmed to do so performs error recovery procedures to attempt to recover the data The error recovery procedures used depend on the options previously set in the Error Recovery Pa...

Страница 40: ...on each command Therefore each command s total recovery time is subject to the recovery time limit Note A recovery time limit of 0 will use the drive s default value of FF FF Minimum recovery time lim...

Страница 41: ...been verified the drive proceeds with the normal write command If the LBAs have not been verified by BMS Pre Scan will convert the write to a write verify to certify that the data was properly written...

Страница 42: ...tor prior to applying power to the drive If you change options after applying power to the drive recycle the drive power to activate the new settings It is not necessary to low level format this drive...

Страница 43: ...to 5 25 inch adapter frame verify with Seagate Technology that the drive can meet the shock and vibration specifications given herein while mounted in such an adapter frame Adapter frames that are av...

Страница 44: ...Table 6 lists the link services supported by Cheetah 15K 7 FC drives Table 6 Link services supported TYPE OF FRAME LINK SERVICE Basic link service frames Abort Sequence ABTS Basic link service reply...

Страница 45: ...l task management responses Table 8 lists the FC SCSI FCP response codes returned for task management functions supported Table 7 Fibre Channel SCSI FCP task management functions TASK NAME SUPPORTED T...

Страница 46: ...ing offset Must 1 Random relative offset Not checked Port Login Accept will return a 0 not supported Valid version level x N_Port F_Port Must 0 N_Port Alternate credit model Must 1 Other bits reserved...

Страница 47: ...00 FS FS 00 FF 00 00 Class 3 80 83 00 01 00 00 84 95 00 00 00 00 00 00 00 00 00 00 00 00 Reserved 96 99 00 00 00 00 100 111 00 00 00 00 00 00 00 00 00 00 00 00 Vendor 112 115 00 00 00 00 Version Tabl...

Страница 48: ...2 00 CC CC 32 35 CC UI UI UI 36 47 00 00 00 00 00 00 00 00 00 00 00 00 Class 1 48 51 00 00 00 00 52 63 00 00 00 00 00 00 00 00 00 00 00 00 Class 2 64 67 00 00 00 00 68 79 80 00 00 00 00 00 08 40 00 00...

Страница 49: ...checked The FC AL drive uses BB Credit of zero 0 CF Common features This binary field selects the common features requested by the fabric login MSB Continuously increasing offset x Random relative of...

Страница 50: ...to prevent an address conflict Note When a Cheetah 15K 7 FC drive is connected in loops with previous Seagate FC drive products Barracuda 4LP FC ST32171FC ST34371FC and ST34571FC Barracuda 9FC ST1917...

Страница 51: ...h Y Read N Y Executable Check Condition 0Ah Y Write N Y Executable Check Condition 0Bh Y Seek N N Executable Executable 12h Y Inquiry Y N Executable Executable Y Vital product data page 00h Y Unit ser...

Страница 52: ...e address 2Fh Y Verify 10 BYTCHK 0 N Y Executable Executable Y Verify 10 BYTCHK 1 N Y Executable Check Condition Y Disable page out Y Byte check N Relative address 30h N Search data high 31h N Search...

Страница 53: ...ion 41h Y Write same 10 N Y Executable Check Condition N PBdata N LBdata 42 4Bh N Not used 4Ch Y Log Select Y N Executable Executable 4Dh Y Log Sense Y N Executable Executable Y Support Log page 00h Y...

Страница 54: ...h Y PI only Verify 32 BYTCHK 0 N Y Executable Executable 7Fh Y PI only Verify 32 BYTCHK 1 N Y Executable Check Condition 80h N XD write extended 81h N Rebuild 82h N Regenerate 83 8Eh N Not used 8Fh Y...

Страница 55: ...ngeable by the Mode Select command get their values from default values storage When power is applied to the drive it takes saved values from the media and stores them as current values in volatile me...

Страница 56: ...hex value FF equates to the binary pattern 11111111 If there is a zero in any bit position in the field it means that bit is not changeable Since all of the bits in byte 02 are ones all of these bits...

Страница 57: ...0 00 00 00 00 00 00 00 00 00 00 00 00 DEF 87 0a 00 0b ff 00 00 00 00 00 ff ff CHG 87 0a 0f ff 00 00 00 00 00 00 ff ff DEF 88 12 14 00 ff ff 00 00 ff ff ff ff 80 20 00 00 00 00 00 00 CHG 88 12 a5 00 00...

Страница 58: ...0 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 DEF 87 0a 00 0b ff 00 00 00 00 00 ff ff CHG 87 0a 0f ff 00 00 00 00 00 00 ff ff DEF 88 12 14 00 ff ff 00 00 ff ff ff ff 80 20 00 00 00 00 00 00...

Страница 59: ...0 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 DEF 87 0a 00 0b ff 00 00 00 00 00 ff ff CHG 87 0a 0f ff 00 00 00 00 00 00 ff ff DEF 88 12 14 00 ff ff 00 00 ff ff ff ff 80 20 00 00 00 00 00 00...

Страница 60: ...event notification N Synchronized locked spindle operation Y Segmented caching N Zero latency read Y Queue tagging up to 128 queue tags supported Y Deferred error handling Y Parameter rounding control...

Страница 61: ...devices A maximum of 127 devices may have addresses however one of the addresses is reserved for a fabric port switch device This means 126 addresses are available for FC AL devices More FC AL compati...

Страница 62: ...r for DC power FC AL interface Drive select device identification Option selection Enclosure Services interface This 40 pin connector is designed to plug directly into a backpanel External cables are...

Страница 63: ..._5 TTL input output 33 Port B_out FC Diff output pair 14 SEL_4 TTL input 34 Port B_out 15 SEL_3 TTL input output 35 Ground 16 Fault LED out Open collector out 36 SEL_2 TTL input output 17 DEV_CTRL_COD...

Страница 64: ...s evenly as possible among the voltage and ground pins The mating connector pins use shorter contacts to achieve power surge reductions and to aid in hot plugging the drives There are longer voltage c...

Страница 65: ...ull down resistor 1K located with the PBC should be used to insure the bypass is enabled if the disk drive is not installed The Enable Bypass signal is active under failing conditions within the drive...

Страница 66: ...g assigned using the SEL lines and that a soft address will be determined by FC AL loop initialization When the Parallel ESI line is low the enclosure backpanel logic switches to ESI mode if supported...

Страница 67: ...16 79 3B 59 32 66 102 CC 11 17 76 3C 60 31 67 103 CB 12 18 75 3D 61 2E 68 104 CA 13 19 74 3E 62 2D 69 105 C9 14 20 73 3F 63 2C 6A 106 C7 15 21 72 40 64 2B 6B 107 C6 16 22 71 41 65 2A 6C 108 C5 17 23 6...

Страница 68: ...ics Table 29 provides the TTL characteristics Table 28 Device control code values 2 PIN 17 1 PIN 18 0 PIN 39 DEFINITION 0 0 0 Reserved for power failure warning 0 0 1 Reserved for auto negotiation of...

Страница 69: ...ignal without rise and fall time degradation You must AC couple the receiver to isolate potentially different DC characteristics of the outputs and the receiver Figure 16 provides the data output vali...

Страница 70: ...nputs are AC coupled on the drive Figure 17 Receive eye diagram Table 33 Eye diagram data values LINK RATE 1 GHZ 2 GHZ 4 GHZ Bit time 941 ps 470 ps 235 ps XMIT eye 725 ps min 315 ps min 158 2 1 1 Shor...

Страница 71: ...d Media Scan 36 backpanel 57 backplane 61 Band 0 33 BandMasterX 32 basic link service frames 39 Basic_Accept BA_ACC 39 Basic_Reject BA_RJT 39 BB 41 44 BB Credit 41 44 BMS 36 buffer data 7 space 12 bus...

Страница 72: ...nting 30 38 drive orientation 37 drive select 57 driver signals 64 drivers and receivers 7 dual port support 45 E electrical description of connector 57 signal characteristics 63 specifications 20 ele...

Страница 73: ...ration options 7 Idle Read After Write 36 Implemented operating def page command 46 Information exceptions control page 1Ch command 47 Initiator control 41 Inquiry command 46 inquiry data 50 installat...

Страница 74: ...ing configuration dimensions 30 MSID 32 MTBF 15 N N_Port Login PLOGI 39 payload 41 payload values 42 NN 41 44 Node Name 44 Node name 41 noise audible 3 noise immunity 21 non operating 26 27 29 tempera...

Страница 75: ...eads 10 Reassign blocks command 46 Receive buffer field size 41 44 receive buffer field size 42 Receive diagnostic results command 47 receive eye diagram 65 receivers 59 recommended mounting 28 Recove...

Страница 76: ...40 Function complete 00 40 Function not supported 05 40 Function reject 04 40 task set full status 55 TCG 32 TCG Storage Architecture Core Specification 3 temperature 26 37 limits 26 non operating 26...

Страница 77: ...ted States 408 658 1000 ASIA PACIFIC Seagate Singapore International Headquarters Pte Ltd 7000 Ang Mo Kio Avenue 5 Singapore 569877 65 6485 3888 EUROPE MIDDLE EAST AND AFRICA Seagate Technology SAS 16...