Seagate BarraCuda Pro v6 Serial ATA Product Manual, Rev. A
5
2.0
Drive specifications
Unless otherwise noted, all specifications are measured under ambient conditions, at 25°C, and nominal power. For convenience, the
phrases
the drive
and
this drive
are used throughout this manual to indicate the following drive models:
2.1
Specification summary tables
The specifications listed in the following tables are for quick reference. For details on specification measurement or definition, see the
appropriate section of this manual.
Table 1 Drive specifications summary
512E models
512N model
ST8000DM005
ST6000DM004
ST4000DX003
ST2000DX003
Drive specification
ST8000DM005
ST6000DM004
ST4000DX003
ST2000DX003
Formatted (512 bytes/sector)*
8TB
6TB
4TB
2TB
Guaranteed sectors
)
Heads
12
7
4
Discs
6
4
2
Bytes per logical sector
512E
512N
Bytes per physical sector
4096
512
Recording density, KBPI (Kb/in max)
2018
1936
Track density, KTPI (ktracks/in avg.)
369
330
Areal density, (Gb/in
2
avg)
732
651
Spindle speed (RPM)
7200
Internal data transfer rate (Mb/s max)
2396
2585
Maximum Sustained data transfer rate OD
214 MB/s
195 MB/s
I/O data-transfer rate (MB/s max)
600
ATA data-transfer modes supported
PIO modes 0–4
Multiword DMA modes 0–2
Ultra DMA modes 0–6
Cache buffer
256MB (262,144KB)
128MB (129,536KB)
Weight: (maximum)
780g (1.72 lb)
680g (1.50 lb)
550g (1.21 lb)
Average latency
4.16ms
Power-on to ready (sec) (typ/max)
23/30
17
Standby to ready (sec) (typ/max)
23/30
17
Startup current (typical) 12V (peak)
2.0A
Voltage tolerance (including noise)
5V +10/-5%
12V ±10%
Non-Operating ambient temperature (°C)
–40° to 70°
Operating ambient temperature (min °C)
5°
Operating temperature (Drive case max °C)
60°
†
Temperature gradient
(°C per hour max)
20°C (operating)
30°C (non-operating)
Relative humidity
5% to 95% (operating)
5% to 95% (non-operating)
Relative humidity gradient
30% per hour max
Altitude, operating
–304.8 m to 3,048 m
(–1000 ft to 10,000+ ft)
Altitude, non-operating
(below mean sea level, max)
–304.8 m to 12,192 m
(–1000 ft to 40,000+ ft)
Operational Shock (max at 2 ms)
Read 70 Gs / Write 40 Gs
Non-Operational Shock (max at 2 ms)
250 Gs
300 Gs