Seagate BarraCuda Pro Serial ATA Product Manual, Rev. A
26
www.seagate.com
Configuring and mounting the drive
1.3.4
Drive mounting
Users can mount the drive in any orientation using four screws in the side-mounting holes or four screws in the
bottom-mounting holes. See
for drive mounting dimensions. Follow these important mounting precautions
when mounting the drive:
Allow a minimum clearance of 0.030 in (0.76mm) around the entire perimeter of the drive for cooling.
Use only 6-32 UNC mounting screws.
The screws should be inserted no more than 0.140 in (3.56mm) into the bottom or side mounting holes.
Do not overtighten the mounting screws (maximum torque: 6 in-lb).
1.3.4.1
Mechanical specifications
Refer to
for detailed mounting configuration dimensions. See
, “Drive mounting.”
NOTE
www.snia.org/technology-communities/sff/specifications.
Figure 3.
Mounting configuration dimensions
NOTE
The image is for mechanical dimension reference only and may not represent the actual drive.
Weight:
1.521 lb
690 g
2X 1.625±.020
2X 3.000±.010
4.000±.010
LQ
1.432
.125±.010
3.750±.010
.814
2.000
4X 6-32 UNC 2B
3 MIN THREAD DEPTH
.14 MAX FASTENER PENETRATION
MOUNTING HOLE.
MAX TORQUE 6 IN/LBS
B
Y
.250±.010
5.787
LQ
MAX
146.
MM
1.122±.020
LQ
4.000±.010
1.638±.010
2X 6-32 UNC 2B
3 MIN THREAD DEPTH
.14 MAX FASTENER PENETRATION
MOUNTING HOLES BOTH SIDES.
MAX TORQUE 6 IN/LBS
Y
Z
1.028
LQ
MAX
26.11MM
.138 ±.015
2.000
CL OF DRIVE
CL OF DRIVE
CL OF CONN
Z
28.50 ±.51 mm
101.60 ±.25 mm