Barracuda ES.2 FC Product Manual, Rev. B
A Drive Not Ready condition is reported by the drive under the following conditions:
• Motor will not spin
• Motor will not lock to speed
• Servo will not lock on track
• Drive cannot read configuration tables from the disc
In these conditions, the drive responds to a Test Unit Ready command with an 02/04/00 or 02/04/03 code.
5.2.6.2.2
Invoking DST
To invoke DST, submit the Send Diagnostic command with the appropriate Function Code (001b for the short
test or 010b for the extended test) in bytes 1, bits 5, 6, and 7.
5.2.6.2.3
Short and extended tests
DST has two testing options:
1.
short
2.
extended
These testing options are described in the following two subsections.
Each test consists of three segments: an electrical test segment, a servo test segment, and a read/verify scan
segment.
Short test (Function Code: 001b)
The purpose of the short test is to provide a time-limited test that tests as much of the drive as possible within
120 seconds. The short test does not scan the entire media surface, but does some fundamental tests and
scans portions of the media. A complete read/verify scan is not performed and only factual failures will report a
fault condition. This option provides a quick confidence test of the drive.
Extended test (Function Code: 010b)
The objective of the extended test option is to empirically test critical drive components. For example, the seek
tests and on-track operations test the positioning mechanism. The read operation tests the read head element
and the media surface. The write element is tested through read/write/read operations. The integrity of the
media is checked through a read/verify scan of the media. Motor functionality is tested by default as a part of
these tests.
The anticipated length of the Extended test is reported through the Control Mode page.
5.2.6.2.4
Log page entries
When the drive begins DST, it creates a new entry in the Self-test Results Log page. The new entry is created
by inserting a new self-test parameter block at the beginning of the self-test results log parameter section of the
log page. Existing data will be moved to make room for the new parameter block. The drive reports 20 param-
eter blocks in the log page. If there are more than 20 parameter blocks, the least recent parameter block will be
deleted. The new parameter block will be initialized as follows:
1. The Function Code field is set to the same value as sent in the DST command
2. The Self-Test Results Value field is set to Fh
3. The drive will store the log page to non-volatile memory
After a self-test is complete or has been aborted, the drive updates the Self-Test Results Value field in its Self-
Test Results Log page in non-volatile memory. The host may use Log Sense to read the results from up to the
last 20 self-tests performed by the drive. The self-test results value is a 4-bit field that reports the results of the
test. If the field is set to zero, the drive passed with no errors detected by the DST. If the field is not set to zero,
the test failed for the reason reported in the field.
Содержание Barracuda ES.2 FC
Страница 1: ...Product Manual Barracuda ES 2 FC 100498209 Rev B June 2008 ST31000640FC...
Страница 3: ...Barracuda ES 2 FC Product Manual Rev B i...
Страница 4: ...ii Barracuda ES 2 FC Product Manual Rev B...
Страница 8: ...iv Barracuda ES 2 FC Product Manual Rev B...
Страница 10: ...2 Barracuda ES 2 FC Product Manual Rev B...
Страница 14: ...6 Barracuda ES 2 FC Product Manual Rev B...
Страница 30: ...22 Barracuda ES 2 FC Product Manual Rev B...
Страница 40: ...32 Barracuda ES 2 FC Product Manual Rev B...
Страница 48: ...40 Barracuda ES 2 FC Product Manual Rev B...
Страница 74: ...66 Barracuda ES 2 FC Product Manual Rev B...
Страница 83: ......