30
Barracuda 7200.7 Product Manual, Rev. D
27–46
Drive model number: (40 ASCII charac-
ters, padded with blanks to end of string)
ST3160021A
ST3160023A
ST3120022A
ST3120026A
ST380011A
ST380013A
ST340014A
47
(Bits 7–0) Maximum sectors per interrupt
on Read multiple and Write multiple (16)
8010
H
48
Reserved
0000
H
49
Standard Standby timer, IORDY sup-
ported and may be disabled
2F00
H
50
ATA-reserved
0000
H
51
PIO data-transfer cycle timing mode
0200
H
52
Retired
0200
H
53
Words 54–58, 64–70 and 88 are valid
0007
H
54
Number of current logical cylinders
xxxx
H
55
Number of current logical heads
xxxx
H
56
Number of current logical sectors per log-
ical track
xxxx
H
57–58
Current capacity in sectors
xxxx
H
59
Number of sectors transferred during a
Read Multiple or Write Multiple command
xxxx
H
60–61
Total number of user-addressable LBA
sectors available
(see Section 2.2 for related information)
*Note: The maximum value allowed in
this field is: 0FFFFFFFh (268,435,455
sectors, 137 Gbytes). Drives with capaci-
ties over 137 Gbytes will have
0FFFFFFFh in this field and the actual
number of user-addressable LBAs speci-
fied in words 100-103. This is required for
drives that support the 48-bit addressing
feature.
ST3160021A =0FFFFFFFh*
ST3160023A =0FFFFFFFh*
ST3120022A = 234,441,648
ST3120026A = 234,441,648
ST380011A = 156,301,488
ST380013A = 156,301,488
ST340014A = 78,165,360
Word
Description
Value
Содержание Barracuda 7200.7 ST3120022A
Страница 2: ......
Страница 6: ......
Страница 10: ...viii Barracuda 7200 7 Product Manual Rev D...
Страница 12: ...2 Barracuda 7200 7 Product Manual Rev D...
Страница 46: ...36 Barracuda 7200 7 Product Manual Rev D...
Страница 52: ...42 Barracuda 7200 7 Product Manual Rev D...
Страница 57: ......