Cheetah 15K.3 SCSI Product Manual, Rev. G
57
9.6.2
SCSI interface physical description
Cheetah 15K.3 drives support the physical interface requirements of the Ultra320 SCSI Parallel Interface-4
(SPI-4) standard and operate compatibly at the interface with devices that support earlier SCSI-2 and SCSI-3
standards. It should be noted that this is only true if the systems engineering has been correctly done, and if
earlier SCSI-2 and SCSI-3 devices respond in an acceptable manner (per applicable SCSI Standards) to reject
newer Ultra320 protocol extensions that they don’t support.
The drives documented in this manual support single-ended and low voltage differential physical interconnects
(hereafter referred to as SE and LVD, respectively) as described in the corresponding ANSI SPI document ref-
erenced in the preceeding two paragraphs. These drives implement driver and receiver circuits that can oper-
ate either SE or LVD. However, they cannot switch dynamically between SE and LVD operation.
The drives typically operate on a daisy-chain interface in which other SCSI devices are also operating. Devices
on the daisy chain must all operate in the same mode, either SE or LVD, but not a mixture of these. On the
interface daisy chain, all signals are common between all devices on the chain, or bus, as it is also called. This
daisy chain of SCSI devices must be terminated at both ends with the proper impedance in order to operate
correctly. Do not terminate intermediate SCSI devices. In some cases, the SCSI devices at each end have
onboard termination circuits that can be enabled by installation of a jumper plug (
TE
) on the device. These ter-
mination circuits receive power from either a source internal to the device, or from a line in the interface cable
specifically powered for that purpose. LC and LW model drives do not have onboard termination circuits. Some
type of external termination circuits must be provided for these drives by the end user or designers of the
equipment into which the drives will be integrated. See the SPI-4 standard for the maximum number of devices
that can successfully operate at various interface transfer rates on SE and LVD daisy chains.
LC model drives plug into PCBA or bulkhead connectors in the host. They may be connected in a daisy-chain
by the host backplane wiring or PCBA circuit runs that have adequate DC current carrying capacity to support
the number of drives plugged into the PCBA or bulkhead connectors. A single 80-pin I/O connector cable can-
not support the DC current needs of several drives, so no daisy-chain cables beyond the bulkhead connectors
should be used. A single drive connected via a cable to a host 80-pin I/O connector is not recommended.
Table 14 shows the interface transfer rates supported by the various drive models defined in this manual.
Содержание 15K.3 - Cheetah - Hard Drive
Страница 1: ...Cheetah 15K 3 SCSI Disc Drive ST373453LW LC ST336753LW LC ST318453LW LC Product Manual Volume 1...
Страница 2: ......
Страница 3: ...Cheetah 15K 3 SCSI Disc Drive ST373453LW LC ST336753LW LC ST318453LW LC Product Manual Volume 1...
Страница 6: ......
Страница 10: ......
Страница 12: ...2 Cheetah 15K 3 SCSI Product Manual Rev G...
Страница 22: ...12 Cheetah 15K 3 SCSI Product Manual Rev G...
Страница 30: ...20 Cheetah 15K 3 SCSI Product Manual Rev G...
Страница 41: ...Cheetah 15K 3 SCSI Product Manual Rev G 31 Figure 15 Recommended mounting Z Y X Z Y X...
Страница 54: ...44 Cheetah 15K 3 SCSI Product Manual Rev G...
Страница 86: ...76 Cheetah 15K 3 SCSI Product Manual Rev G...
Страница 92: ......
Страница 93: ......