Seagate Video 2.5 Product Manual, Rev. H
16
Drive Specifications
2.10
Electromagnetic Immunity
When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the
radio frequency (RF) environment as defined in
2.10.1 DC Magnetic Field Immunity
Table 8
Radio Frequency Environments
Test
Description
Performance
Level
Reference
Standard
Electrostatic discharge
Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV
B
EN 61000-4-2: 95
Radiated RF immunity
80 to 1GHz, 3 V/m, 80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz
A
EN 61000-4-3: 96
ENV 50204: 95
Electrical fast transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN 61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common, AC mains
B
EN 61000-4-5: 95
Conducted RF immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine
A
EN 61000-4-6: 97
Power Frequency H-field immunity
1 A/m, 50Hz/60Hz, 3 axes
A
EN 61000-4-8: 97
Voltage dips, interrupts
30% Reduction for 25 cycles
>95% Reduction for 250 cycles
>95%, 0.5 cycles
C
C
B
EN 61000-4-11: 94
Table 9
DC Magnetic Field Immunity
Test
Product Spec (Standalone)
DC Magnetic Field Immunity
1, 2, 3
400 Gauss, RMS
1
Field in Gauss at the drive envelope. Testing per procedures 20800109-349 and 20800109-350.
2
Passing Field in Gauss at the drive envelope. In practice, testing is conducted using a fixed distance from the bottom of the mag-
net to the top of the drive. Calibration of the field vs. distance is done with a Hall probe with no magnetic materials present.
3
Testing to be done with magnet.375” dia. x 0.100” Ni-plated NdFeB; B,~11.5 kG, magnetized along its length; the magnet is ori-
ented with the length perpendicular to the drive cover/PCBA. Drive to be properly secured during test.