Seagate IronWolf Product Manual, Rev. A
15
Drive Specifications
2.8.4 Altitude
2.8.5 Shock
All shock specifications assume that the drive is mounted securely with the input shock applied at the drive mounting
screws. Shock may be applied in the X, Y or Z axis.
2.8.5.1
Operating shock
These drives comply with the performance levels specified in this document when subjected to a maximum operating
shock of 70 Gs based on half-sine shock pulses of 2ms during read operations. Shocks should not be repeated more than
two times per second.
2.8.5.2
Non-operating shock
The non-operating shock level that the drive can experience without incurring physical damage or degradation in
performance when subsequently put into operation is 250 Gs based on a non-repetitive half-sine shock pulse of
2ms duration.
2.8.6 Vibration
All vibration specifications assume that the drive is mounted securely with the input vibration applied at the drive
mounting screws. Vibration may be applied in the X, Y or Z axis. Throughput may vary if improperly mounted.
2.8.6.1
Operating vibration
The maximum vibration levels that the drive may experience while meeting the performance standards specified in this
document are specified below.
2.8.6.2
Non-operating vibration
The maximum non-operating vibration levels that the drive may experience without incurring physical damage or
degradation in performance when subsequently put into operation are specified below.
Operating
–304m to 3048m (–1000 ft. to 10,000 ft.)
Non-operating
–304m to 12,192m (–1000 ft. to 40,000+ ft.)
10Hz to 22Hz
0.25 Gs (Limited displacement)
22Hz to 350Hz
0.50 Gs
350Hz to 500Hz
0.25 Gs
5Hz to 22Hz
3.0 Gs (Limited displacement)
22Hz to 350Hz
3.0 Gs
350Hz to 500Hz
3.0 Gs