Revision 2012.02.27
10
LOCK
Your vendor has one Lock, more commonly known as T-handle lock. To unlock the front door, insert key and turn
clockwise ¼ turn. When unlocked the ‘T’ of the Lock will pop out from its base. Turn the ‘T’ 15 to 20 times counter clock
wise to unlock the door. To Lock the door turn the ‘T’ handle clockwise 15 to 20 times and then push the ‘T’ inside the
Lock to lock the door. Key can now be removed. Note: Do not over-tighten when locking – this could strip the threads and
damage your machine.
REFRIGERATION
If you purchased a refrigerated model, please see special information throughout the manual regarding refrigeration,
settings and other information. The refrigeration system consists of Compressor, Relay circuit, Accumulator, condenser,
condenser fan, evaporator, evaporator fans and air duct. The entire refrigeration system is modular and has a separate
internal power cord, which is plugged in on the plug point provided at the bottom area below the last tray. The power
switch has to be turned ON in order to start up the refrigeration system. There is a door switch that controls the
refrigeration system ON and OFF condition. When the door is opened, the door switch is not depressed and the
refrigeration system shuts OFF. When the door is closed, the switch is activated and the evaporator fans starts turning.
There will be a delay before compressor starts running after the door closure.
There is a vent on the cabinet back to blow the air from condenser. The inlet vent is at the bottom of the cabinet in front of
the condenser. The condenser has to be cleaned regularly. The recommended frequency is once every two weeks.
There are 6 clips around the front of the refrigeration module that has to be un-hooked in order to remove the front door of
the refrigeration module. This will provide the access to the condenser. Either using fin-comb or a brush, clean the lint in
between the condenser fins. Note: Be careful not to bend the fins – this could restrict airflow and damage your machine.
The compressor and the relay circuit, condenser fan motor and drain pan can be accessed in the same manner by
removing the front door. The refrigeration system has to be unplugged and the module has to slide completely outside in
order to gain access to these components.
SECTION 3 OPERATION
Installed, side view.
Installed, Front View
Installed
Installed, Top View