Страница 2: ... surge protection systems is highly recommended in order to protect and extend the life of your equipment Table of Contents 1 Introduction 2 1 1 Product Introduction 2 1 2 Features 2 1 3 Package List 2 2 Panel Description 3 2 1 Front Panel 3 2 2 Rear Panel 4 3 System Connection 6 4 Control Software 7 4 1 Basic Setting 7 4 2 Panel Set 10 4 3 Action List 11 4 4 Event setting 12 4 4 1 RS232 Setting 1...
Страница 3: ...mute button 3 built in programmable RS232 2 RS485 and 2 IR connectors Each button can be programmed to send RS232 RS485 IR or TCP IP commands simultaneously to control third party devices The unit can be easy configured using the supporting control panel via the ENTERNET port The volume control buttons is specially designed for various applications Crystal and backlit buttons with easy user friend...
Страница 4: ...OFF MUTE VOLUME 1 2 3 4 5 SDCP9 UK DISPLAY ON DISPLAY OFF MUTE VOLUME 1 2 3 4 5 No Name Description 1 Button 6 crystal and luminescent buttons programmable functions can be customized via the Control Software Each label within a button can be easily changed Simply select the label you need and change it as shown below ...
Страница 5: ...ns for specific application 5 MUTE The button can be customized as Toggle Mute and Unmute buttons for specific application 2 2 Rear Panel SDCP9 EU TX RX TX RX TX RX IR TCP IP 12V PWR Y Z Y Z IR 1 IR 2 1 2 6 7 3 4 5 SDCP9 UK 12V PWR Y Z Y Z TX RX TX RX TX RX IR TCP IP IR 1 IR 2 1 2 6 7 3 4 5 No Name Description 1 ETHERNET RJ45 connector for connecting PC to run the Control Software to customize the...
Страница 6: ... 4 RS485 5 2 pin RS485 terminal blocks for connecting the third party devices which need to be controlled via RS485 4 IR 1 IR 2 2 pin IR terminal blocks for connecting with IR emitters to control the third party devices via IR 5 PWR 12V 2 pin terminal block for connecting 12V DC power adaptor 6 IR Sensor Built in IR receiver for receiving IR code from IR remote to build the IR database 7 RESET Pre...
Страница 7: ...Wireless Route 3 Connect the third party devices such as matrix switcher and scaler switcher to the LAN port of Wireless Route 4 Connect the third party devices such as matrix switcher scaler switcher and projector to RS232 1 RS232 2 and RS232 3 ports 5 The third party devices which support RS485 communication can be connected to RS485 4 and RS485 5 ports 6 Connect the IR Emitters to IR 1 and IR 2...
Страница 8: ... system connection 2 The default IP of SDCP9 is 192 168 0 178 modifiable the network segment of control PC must be set the same as the SDCP9 s 3 Installation uninstallation of Control Software Installation Copy the software package to the control PC Uninstallation Delete all the software files in corresponding file path 4 Double click the below icon to run this software Same network segment as the...
Страница 9: ...button actions and any action can be chosen for setting events Show IP addresses of all connected wallplate control panels in LAN Panel Set Click any button to set its action Set events for the selected key action Show all events for the selected key action Show all key actions and any action can be chosen for setting events Show IP addresses of all connected wallplate control panels in LAN Panel ...
Страница 10: ... Update Open upgrade Web page http 192 168 0 178 4001 on IE Type User ID admin and Password 123456 upload update file Click Upload Click Reset MCU Click System Factory Defaults to restore factory defaults Click Connection TCP IP Reconnect to refresh all connected SDCP9 Click Connection Read from Device to load the MCU data of the selected SDCP9 to control software Click Connection Write to Device ...
Страница 11: ... software Buttons 1 6 KNOB MUTE ON OFF correspond to the buttons on SDCP9 For example click the button 1 to set its key action as below Key Type Press Execute events when press button Release Execute events when release button Toggle The button can be regard as composite key press and press again to execute different events Built key group for LED setting ...
Страница 12: ...www seada co uk 11 26 E mail sales seada co uk 4 3 Action List All key actions will be shown on the below action list Delete the selected action Delete all invalid actions which have no events Empty all actions ...
Страница 13: ... about how to set events for each action 4 4 1 RS232 Setting This item is used for setting the events of the selected key action to control the third party device through RS232 1 3 and RS485 4 5 ports Operation procedure 1 Select a key action in action list 2 Set the Lib Name and Lib Function as needed 3 Select the RS232 485 port 4 Confirm and set the baud rate data bit stop bit and parity 5 Type ...
Страница 14: ... click Edit Lib to create a new library file as below Note Once set up please press Save to save the setting or press Save as to save the setting as a file and then press OK 7 The number of transmission strings and the delay time between strings can be set Open create a library Type RS232 command for device control Create delete the function name of the command ...
Страница 15: ...Website www seada co uk 14 26 E mail sales seada co uk 4 4 2 IR Setting This item is used for setting the events of the selected key action to control the third party device through IR 1 2 ports ...
Страница 16: ... to save the setting or Save as to save as a file and then press OK IR leaning procedure 1 Click Learn to enter IR learning mode 2 Put the IR Remote close to the IR sensor of wallplate control panel 3 Press any button on the IR Remote to send the IR code to the IR sensor and the IR edit box will refresh the IR data 4 Follow the above steps can learn other function of the remote buttons Note The IR...
Страница 17: ...Website www seada co uk 16 26 E mail sales seada co uk 8 The number of transmission strings and the delay time between strings can be set ...
Страница 18: ... mail sales seada co uk 4 4 3 TCP IP Setting This item is used for setting the events of the selected key action to control the third party device through TCP IP port Type the IP address of third party device Type the control command ...
Страница 19: ...item is used for setting the delay time between two events If set the delay time to be 3 seconds it means that the first event starts executing at 12 00 00 followed by the second event executing at 12 00 00 03 The delay time setting showed as below Hour 0 23 Minute 0 59 Second 0 59 ...
Страница 20: ...ending command The compare setting showed as below Operation procedure 1 Select the key action in action list 2 Select the RS232 port 3 Set the command format ASCII or Hex and then set the terminator for ASCII 4 Type the correct RS232 command in data box and then press add to save the command 5 Add an event that the LED lights up to indicate the comparison result 6 The executing priority of events...
Страница 21: ...programmable buttons to indicate the results of executing event On Switch on the LED of the selected Key1 Off Switch off the LED of the selected Key1 On Other off Switch on the LED of the selected Key1 and switch off the others On Group off Switch on the LED of the selected Key1 and switch off the others in the same group ...
Страница 22: ...s seada co uk 4 4 7 Toggle Setting The key action type can be set as Toggle that enable the button to be a composite key Here take Key1 as an example to introduce the Toggle Setting Operation procedure 1 Click 1 and set its key type as Toggle ...
Страница 23: ...Website www seada co uk 22 26 E mail sales seada co uk 2 Add toggle RS232 events for the key action 3 Press the button 1 to execute the second event and then press again to execute the fourth event ...
Страница 24: ... shows all events of the selected key action The executing priority of events is from top to bottom see the picture below If there is an event execute incorrectly all subsequent events will not be executed Delete the selected event Adjust the execution order for events Empty all events ...
Страница 25: ...Programmable buttons 2 Programmable display control buttons 1 Programmable volume knob 1 Programmable MUTE button Other 1 Built in IR sensor Baud Rate Supports 2400 4800 9600 19200 38400 56000 57600 115200 Software SDCP9 Power Consumption 1W Max Operation Temperature 10 55 Storage Temperature 25 70 Relative Humidity 10 90 Power Supply Input 100VAC 240VAC 50 60 Hz Output 12VDC 1A Net Weight About 3...