4

accessory hoses. Ensure that the second stage
and octopus are pointing down and away from
yourself and anybody standing close by,
checking that the second stage hose goes
towards right (exhalation outlets of the second
stage positioned downward). Open your tank
valve slowly to avoid a sudden and strong flow
of air into the regulator.

Be sure that the tank valve is completely
open before starting the dive.

-Press the purge button two or three times

to remove any dust or foreign matter that may
have accumulated in the second stage. Then
check the operation of your second stage by
breathing through  it.

- On entering the water when the regulator

is not in your mouth it is advisable to fill it
with water to reduce the risk of sudden
discharge of air. This is done by gently shaking
and rotating the second stage while it is sub-
merged.

- When using a second regulator or  octo-

pus, it is advisable to fit a mouthpiece
cover/retainer/plug. This should prevent forei-
gn matter from entering the regulator and redu-
ce the risk of uncontrolled air discharge. This
accessory is available from you dealer.

AFTER EACH DIVE - PERIODICAL

MAINTENANCE

Even though your regulator is manufactured
with high quality materials specifically tested
in sea water it is necessary to apply care to
avoid corrosion and deposits due to salt water.
We have listed below step by step instruction

for the care of your regulator after diving.

-As soon as the tank is on the boat or you

have left the water, close the tank valve, relea-
se the air left into the regulator by depressing
the second stage purge button and disconnect
the regulator by releasing the yoke screw.

-Lay down the tank to avoid it falling and

damaging equipment or injuring people.

-Clean and dry  the 1st stage filter and its

seat using a light compressed air blow.

-Repeat the same operation on the filter

dust cover, place it on the filter and tighten the
yoke screw.

-As soon as possible, carefully rinse each

part of the regulator with fresh water. During
this operation do not remove the dust cover
from the filter of the 1st stage and in order to
avoid water penetration inside the regulator do
not depress the second stage purge button.

-If you are not going to use the regulator

for a few weeks attach the regulator to a tank
and, by depressing the purge button on the
second stage, let the air flow for ten seconds.
This will eject any water thereby helping to eli-
minate problems of deposit and bad odour.

-Let the regulator dry avoiding direct sun

light and dust, hanging it from the yoke in
order to avoid bending occurring in the low
pressure hose.

-At the end of EVERY season, or in any

case after a long period of storage, it is advisa-
ble to have the regulator inspected and serviced
by a certified service centre. We suggest that
you contact an authorised  SEAC SUB dealer
who will be happy to arrange for the mainte-
nance of your regulator.

Содержание OCTOPUS SORIUS

Страница 1: ...0474 EN 250 EROGATORI SEAC SUB REGULATORS SEAC DIVING PRO S r l Via D Norero 29 16040 S Colombano Certenoli Ge Italy Tel 39 0185 356 301 Fax 39 0185 356 300 ...

Страница 2: ...long period of time Improper use and maintenance of your regulator could seriously impair its perfor mance SEAC SUB will not accept any responsibility with respect to any problem due to failure to follow the recommendations provided by this manual In case of any problem please contact an authorised SEAC SUB dealer or in case of dif ficulty contact SEAC SUB Note All service or maintenance of your r...

Страница 3: ...S regulator is designed with a 300 bars working pressure When it is used with pressures over 200 bars it is advisable to use the optional threaded DIN connection to the tank valve instead of the standard INT yoke connection SORIUS and SORIUS 1000 REGULATORS 2nd STAGE The main body is made from synthetic resin which is highly resistant to impacts abrasions ultraviolet rays and chemical agents Incor...

Страница 4: ...ported by the Venturi effect This system allows for low consumption of air by reducing air waste as it is designed to per fectly fit the divers air demand The downstream valve also provides maxi mum safety as it is also able to work in case of 1st stage overpressure by releasing the exces sive pressure and allowing the diver to breathe By rotation of the external pre dive control knob it is possib...

Страница 5: ...w step by step instruction for the care of your regulator after diving As soon as the tank is on the boat or you have left the water close the tank valve relea se the air left into the regulator by depressing the second stage purge button and disconnect the regulator by releasing the yoke screw Lay down the tank to avoid it falling and damaging equipment or injuring people Clean and dry the 1st st...

Страница 6: ...PARTI DI RICAMBIO SPARE PARTS COMPOSANTS REPUESTOS ERSATZTEILE 0474 EN 250 EROGATORI SEAC SUB REGULATORS ...

Страница 7: ...US1000body S710009 7 LP portplug S500042 8 HP portplug S500054 9 O Ring 2031 S101017 10 O Ring 108 S510022 11 Piston seat S540005 12 SORIUS1000 main spring S540006 13 O Ring 2018 S540007 14 SORIUS1000 piston S540008 15 O Ring 2100 S540009 16 SORIUS1000 cap S710008 17 O Ring 2037 S510021 18 O Ring 2056 S101024 19 Dustcap S500024 20 SORIUS1000KitDIN200bar S500056 21 O Ring 115 S101023 22 DIN cone sh...

Страница 8: ...ring BK 2012 S500034 26 O Ring 2012 S150004 27 O Ring lock bush S500035 28 Return spring S500036 29 Small balancing piston S500037 30 Small piston bush S500037 B 32 Slide stem S500038 B 33 Slide stem seat S500038 34 First stage diaphragm S500039 35 Diaphragm retainer ring S500040 36 Spring nut plate S500041 38 Setting spring S500044 40 Pressure adjusting ring S500046 41 Seal S720004 42 SORIUS SORI...

Страница 9: ...on flat spring S770005 6 Purge button S770006 7 Label S770007 8 Mouthpiece strap S500023 9 Mouthpiece 236 10 Exhaust valve S500009 11 Exhaust tee S770008 12 Elastic stop nut S500019 13 Adjusting ring S770009 14 Washer S770010 15 Lever S770011 16 Lever pin S770012 17 Spring retainer ring S770013 18 Stem spring S500018 19 Demand valve stem S770014 20 Stem seat S500017 21 O Ring 2043 S101030 22 Lever...

Страница 10: ...007 8 Mouthpiece strap S500023 9 Mouthpiece 236 10 Exhaust valve S500009 11 Exhaust tee S770008 12 Elastic stop nut S500019 14 Washer S770010 15 Lever S770011 16 Lever pin S770012 17 Spring retainer ring S770013 18 Stem spring S500018 19 Demand valve stem S770014 20 Stem seat S500017 21 O Ring 2043 S101030 22 SORIUS ADJ Lever support S800008 23 O Ring 2025 S500021 24 Orifice S500016 25 Flow baffle...

Отзывы: