12
P G
N
9. MANUAL RELEASE SYSTEM
To release the gate:
- Open the red door in front of the operator
to left or right (Fig. 30).
- Insert the hexagon «
T
» key (Fig. 31) and without forcing turn the key clockwise until it stops (Fig. 32).
- Manually open and close the gate.
To reconnect:
- Insert the hexagon «
T
» key and without forcing turn anti-clockwise until it stops (Fig. 32).
- Slowly push the gate manually until the release is re-engaged.
Caution: do not attempt to use the operator electrically before reconnecting the drive.
WARNING: Always switch off the main power (120V) before servicing the operator
RELEASE
Fig. 30
Fig. 31
Fig. 32
Fig. 33
SEA recommend
to release the operator
only in case of power
failure.
Always contact a pro-
fessional installer in
case of malfunctioning
16 Gauge
14 Gauge
12 Gauge
10 Gauge
8 Gauge
4 Gauge
Up to
150 FT
250 FT
400 FT
650 FT
1000 FT
2200 FT
Up to
75 FT
125 FT
200 FT
325 FT
500 FT
1100 FT
P = Single Phase 120 V~
G = Ground
N = Neutral
10. SINGLE PHASE POWER CONNECTION (120 V~ )
120V ~
POWER
WIRE
½ HP
and DUAL
MOTOR
1 HP
ON - OFF
switch
Keep the power cables (motors,
power supply) SEPARATE from
the command cables (push
b u t t o n s , p h o t o c e l l s e t c ) .
In order to avoid any interference
use two separate cable sheaths
WARNING