5. RELEASE SYSTEM
5.1. In order to release do as follows:

-Open the lock cover, insert the key and rotate it 90° clockwise 
(Fig. 6).
- Pull   the release lever until it stops,   about 90° approximately 
(Fig. 7).

Note: when you pull the release lever, the electronic control 
unit receives a stop impulse thanks to a   micro-switch 
placed inside.

5.2. In order to relock do as follows:

- Push the release lever to complete closing.
- Rotate the key counter-clockwise and extract it.
- Close the protective lock cover.
Once the lock has been restored the electronic control unit 
reactivates

6. GEAR RACK MOUNTING

6.1.

Release the motor reducer and take the leaf to complete 

opening;

6.2.

Fix to each gear rack element the   support pawls using the 

appropriate lock screws, taking care to place them in the upper 
part of the hole (Fig. 8) ;

6.3.

Lean the gear rack element   on the toothed pinion of the 

motor so that it results parallel to the ground slideway of the 
gate,   place it as shown in Fig. 9 and electrically weld the central 
pawl B to the gate structure (Fig. 10). 

6.4.

Make sure   that all the gear rack elements are perfectly 

aligned and placed correctly (teeth in phase). It’s suggested to 
place two aligned elements infront of a third one as shown in 
Fig.11;

6.5.

Repeat the above described operation for all the remaining 

gear rack elements   which have to be installed;

6.6.

To avoid that the door weights down on the pinion (Fig.12) 

lift up the whole rack about 1,5 mm. 

Warning

: Keep a gap of about 0,5 mm between pinion tooth 

and gear rack tooth;

6.7.

Make sure that the gear rack works at the center of the 

pinion along all rack elements, if necessary, adjust the

 

distance 

pieces length.

Fig. 6

Fig. 9

A

B

C

Manually move the gate until pawl C is placed in 
correspondence to the pinion, now fix it with electric welding. 
Repeat   the same procedure for pawl A after having placed it in 
correspondence to   the pinion;

Fig. 7

Fig. 8

Fig. 10

Open

l

C ose

cod. 67410325

REV 01 - 04/2007

ENGLISH

Содержание Saturn 1000

Страница 1: ...ree Pinion Z16 Z20 speed Maximum torque Gate maximum weight Mechanical clutch Inductive or mechanical limit switch 230 V 5 50 60 Hz 330W 550W 750W 1 6 A 2 6 A 3 0 A 16 uf 12 5 uf 25 uf 35 35 30 20 C 55 C 150 C 12 Kg 13 Kg 14 5 Kg Electronic Electronic Mechanical IP55 9 5 11 m min 30 Nm 55 Nm 70 Nm 600 Kg 1000 Kg 2000 Kg no with or without yes 600 1000 2000 8 8 9 9 1 1 3 3 6 6 2000 Kg 1800 Kg 1000 ...

Страница 2: ...on plate it is necessary to 2 1 Prepare a concret basement with the dimensions shown in Fig 1 where the foundation plate and the anchor bolts will be concreted NOTE It is recommended gate structure permitting to lift the foundation plate about 50mm from the ground in order to avoid eventual water stagnation Fig 1 2 30 43 58 Fig 3 Fig 5 4 FITTING OF THE MOTOR REDUCER 4 1 Insert the 4 grains into th...

Страница 3: ...on the toothed pinion of the motor so that it results parallel to the ground slideway of the gate place it as shown in Fig 9 and electrically weld the central pawl B to the gate structure Fig 10 6 4 Make sure that all the gear rack elements are perfectly aligned and placed correctly teeth in phase It s suggested to place two aligned elements infront of a third one as shown in Fig 11 6 5 Repeat the...

Страница 4: ...Place the small plate on the gear rack so that the limit switch is small lever in case of mechanical limit switch Fig 14 small pointers placed on the upper part in case of inductive limit switch Fig 15 in corrispondence of pointX which is placed 50 mm from the folded side of the small plate fig 16 and fix it with the delivered screws Fig 17 7 2 In order to install and adjust the limit switch in cl...

Страница 5: ...not being used This is a quotation from the GENERAL DIRECTIONS that the installer must read carefully before installing Packaging materials such as plastic bags foam polystyrene nails etc must be kept out of children s reach as dangers may arise The electrical installation shall be carried out by a professional technician who will release documentation as requested by the laws in force D L 46 90 F...

Страница 6: ... run mains carrying cables in separate ducts to low voltage control cables to prevent mains interference INTENDED USE The SATURN operator has been designed to be solely used for the automation of sliding gates SPARE PARTS To obtain spare parts contact SEAs r l Zona Ind le 64020 S ATTO Teramo Italia SAFETYAND ENVIRONMENTALCOMPATIBILITY Don t waste product packing materials and or circuits When bein...

Отзывы: