16
Verify the battery back up systems by disconnecting the power source (120V)
REMEMBER to turn on the power source after check
Check the operating of all accessories, especially the functioning of all safety devices
and reversing sensors
PERIODICAL MAINTENANCE
Annual
Annual
Annual
Annual
Annual
Annual
Annual
Annual
Annual
Annual
Annual
Annual
Check the release functionality
Check the clutch functionality (if present)
Check the limit-switch conditions and functionality in opening and closing (if present)
Check the fixing screws
Check the connection cables integrity
Check the chain works perfectly and is well greased
Inspect the track for any signs of cracking or separation
Clean the gate track wheels and lubricate them with recommended lubricant
Check the tight of the hardware of the gate
Check for all corroded parts and replace them
All operations MUST be made exclusively by an authorized installer and when main power supply is OFF
After the periodical maintenance operations it is necessary to repeat the test of the automation and its commissioning
RISK EXAMINATION:
The points pointed by arrows are potentially
dangerous. The installer must take a thorough risk examination to prevent
crushing, conveying, cutting, grappling, trapping so as to guarantee a safe
installation for people, things and animals
(
Re. Laws in force in the Country
where the installation has been made)
NOTICE
:
SEA USA
Inc. can not be deemed responsible for any damage or
accident caused by product breaking, being damages or accidents due to a
failure to comply with the instructions herein. The guarantee will be void
and the manufacturer responsability will be nullified if
SEA USA
Inc. original
spare parts are not being used.
The electrical installation shall be carried out by a professional technician who will release documentation as requested by the laws
in force.
Packaging materials such as plastic bags, foam polystyrene etc must be kept out of children’s reach as dangers may arise
WARNINGS
The electrical installation and the operation logics must comply with current regulations. Keep the power cables
(motors, power supply) separated from the control cables (push-buttons, photocells, radio, etc.). Separate conduits should be used
to prevent noise issues.
Note:
Use “cable-glands” and/or “pipes/sheatings” close to the control panel box so to protect the
interconnection cables against pulling efforts
INTENDED USE
The operator has been designed exclusively for the automation of sliding gates
SPARE PARTS
: SEA USA Inc.
- Doral 33172 - Miami (FL) - USA Telephone: ++1-305.594.1151
www.sea-usa.com
ENVIRONMENT SAFETY
We recommend not to spoil the environment with product and circuit packing material
MAINTENANCE AND DECOMMISSION
The decommission or stop or maintenance of the automation system must be carried out
by skilled and expert technicians.
GUARANTEE LIMITS
For the guarantee see the sales conditions
NOTE: THE MANUFACTURER SHALL NOT SHOULDER ANY RESPONSIBILITIES IN CASE OF DAMAGE CAUSED BY
NAPPROPRIATE, WRONG OR CARELESS USE
SEA reserves the right to make all the necessary changes and modifications of the products or manuals without giving prior notice
T
O
THE
ATTENTION
OF
THE
END
-
USERS
AND
TECHNICIANS
GENERAL NOTICE
T
min
-4°F
T
max
+149°F
Humidity
min
5% without condensation
Humidity
max
90% without condensation
STORAGE TEMPERATURE