67410182
MENU FOR INPUT CHECK
The settings of the control unit are made through the UP, DOWN and OK buttons. The UP and DOWN buttons to scroll
through the MENUS and SUBMENUS. By pressing OK you enter from MENU into SUBMENU and confirm the choice.
Moving in the
language
menu pressing the UP and DOWN buttons at the same time you access the SP MENU for
special settings.
Moving in the
language
menu pressing the OK button for 5 seconds, you enter the CHECK MENU, where you can check
the operating status of all inputs.
u.001
seage
UP
OK
UP
UP
UP
DOWN
DOWN
DOWN
OK
OK
OK
DOWN
otOR
U
Initial system
Software Version
Programming example
MENU
SEA
SET
---
--
---
DISPLAY INPUT STATUS
When the segment
is ON during self-
learning, the input
status is closed or
OFF.
Start
Start
pedestrian
Stop
Limit
Switch
opening
motor
Photocell 1
Photocell 2
Edge
Limit
Switch
closing
motor
Sl d
TR pk
L T SU T(H
(LOS NG
U
L T SU T(H
OPEN NG
U
MENU
start
Description
Description
EDGE
PHOTO1
PHOTO2
PedESTR AN Start
END
Start test
Stop test
Pedestrian
start test
Safety edge
test
Photocell 1
test
Photocell 2
test
Opening
limit switch
test
Closing
limit switch
test
The contact must be a N.O. Contact . When activating the related command
on the display SET lights up, the input works.
If SET is always on, check the wirings.
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works. If SET is always on, make
sure that the contact is a N.C. contact or that the related limit switch is not occupied.
The contact must be a N.O. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, check the wirings.
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
IThe contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
The contact must be a N.C. Contact. When activating the related command
on the display SET lights up, the input works. If SET is always on, make
sure that the contact is a N.C. Contact or that the related limit switch is not occupied.
Exit menu
stop
OK
OK
OK
MENU FUNCTION TABLE CHECK
GATE 1 DG R1
INPUTS
To access the Menu for input check keep pressed OK for about 5 seconds.
enabled
blo(ked
enabled
blo(ked
enabled
blo(ked
OK
enabled
blo(ked
Note:
If the
Stop
,
Photocell 1
and
Photocell 2
contacts are not bridged in self-learning, they will be
deactivated and can be reactivated through this menu, without repeating times self-learning.
English
GATE 1 DG R1
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
33
Rev.06 - 09/2014