2.8.

 Drill a hole into the gate (Fig 15) to be able to attach the front bracket with the supplied bolts being careful to place the operator 

perfectly horizontal (Fig 16).

NOTE:

if it is not possible to attach the 
front bracket with the bolts, 
weld it to the gate (Fig 17), 
being careful to protect the 
shaft from welding waste.

ENGLISH

Sistemi Elettronici

di Apertura Porte e Cancelli

International registered trademark n. 804888

®

Fig. 18

Mechanical stop in closing 

Mechanical stop in opening

INSTALLATION OF POSITIVE STOPS

On request mechanical stop in opening and closing available.

REV 06 - 07/2010

67410590

16

Содержание ALPHA 200 STANDARD

Страница 1: ...que intensity and the anti crushing safety are adjustable through the control board Key locked that must be used only in case of emergency and or power failure to manually operate the gate MAIN PARTS...

Страница 2: ...kg Max Leaf Weight Max Leaf Length ALPHA electromechanical operators DIAGRAM FOR THE USE OF ALPHA 200 AND ALPHA 330 ALPHA 330 24V 230V ALPHA 200 24V 230V ALPHA 330 24V 230V Notice The operator must be...

Страница 3: ...pening Limit Switch stop in closing Fig 6 Fig 7 ALPHA 200 STANDARD ALPHA 330 STANDARD 2 INSTALLATION OF THE OPERATORS 2 1 Fix the holed mounting plate to the post using screws as shown in Fig 6 The pl...

Страница 4: ...80 190 190 150 170 200 170 160 160 220 160 Vedi Fig 10 A C Fig 9 60 m m M IN Fig 10 ALPHA 200 STANDARD ALPHA 330 STANDARD Opening angle During selection prefer the higher dimensions of A and B The abo...

Страница 5: ...turn into the opposit direction screw it see Fig 12 and 13 Note After installation in opening leave minimum 15 mm of working stroke to avoid that the operator goes into mechanical lock if necessary in...

Страница 6: ...E if it is not possible to attach the front bracket with the bolts weld it to the gate Fig 17 being careful to protect the shaft from welding waste ENGLISH Sistemi Elettronici di Apertura Porte e Canc...

Страница 7: ...ongue from the shaft cover Fig 20 and mount it on the operator through the two tie rods without excessively tightening the two cover nuts Fig 21 Tie rod 1 Tie rod 2 Cover nuts Cover nuts Fig 19 Sistem...

Страница 8: ...CE SEA s r l can not be deemed responsible for any damage or accident caused by product breaking being damages or accidents due to a failure to comply with the instructions herein The guarantee will b...

Страница 9: ...wrong use of the product can cause sever damages to people 2 The max length of the power supply cable between control unit and motors is 10m use cables with 2 5 mm section Use wirings with double insu...

Страница 10: ...the earth installation has been correctly made connect all the metallic parts of the closing doors gates etc and all the components of the installation provided with earth terminals Apply all the safe...

Отзывы: