Field Service Procedure - Replacement Pol Pot Kit, 6006C, 6009C,
9597B & 9507
Page
5
of
7
Document No
135302 Rev B
Copyright © Sea Tel, Inc 2011 - The information contained in this document is proprietary to Sea
Tel, Inc.. This document may not be reproduced or distributed in any form without prior written
consent of Sea Tel, Inc.
7.
Pol
Pot
Alignment
and
Verification:
1.
Drive
the
reflector
to
zero
degrees
of
elevation
to
view
the
orientation
of
the
feed
assembly:
Press
the
button
to
turn
the
tracking
function
off
(if
applicable)
to
prevent
the
antenna
from
going
into
a
search.
Push
the
button
until
the
‘Antenna’
window
is
displayed
(the
screen
will
show
the
AZ,
EL
and
REL
values).
Press
the
button
twice
to
isolate
the
‘EL’
window
and
then
press
the
arrow
to
activate
it
(a
cursor
will
be
displayed).
Now
use
the
and
arrow
keys
to
scroll
the
cursor
along
and
use
the
and
arrow
keys
to
change
the
elevation
value
to
“00.0”
and
press
the
button.
2.
Set
the
Polang
Type
to
manual
mode:
Enter
the
‘Setup
Menu’
mode
by
pressing
and
holding
the
arrow
keys
together
until
the
‘EL
Trim’
or
‘Auto
Trim’
window
is
displayed.
Push
the
arrow
key
until
the
‘Polang
Type’
window
is
displayed.
Press
the
arrow
key
to
activate
the
window.
Now
use
the
and
arrow
keys
to
scroll
the
cursor
along
and
use
the
and
arrow
keys
to
change
the
characters.
Set
the
‘Polang
Type’
to
“0009”
which
is
manual
mode
and
press
the
button.
3.
Press
the
button
to
go
to
the
‘Pol
Offset’
window
and
verify
the
default
setting
is
“0030”
for
a
9597B
or
9507
or
“0040”
for
a
6006C
or
6009C.
(If
necessary
use
arrow
keys
to
select
appropriate
digits
and
change
accordingly).
4.
Now
keep
pressing
the
button
until
the
‘Antenna’
window
is
displayed
(the
screen
will
show
the
AZ,
EL
and
REL
values).
5.
Press
the
button
4
times
until
‘Pol
xxx’
is
displayed
and
then
press
the
arrow
key
to
activate
the
window.
6.
Now
hold
either
the
or
arrow
key
to
drive
the
pol
until
a
count
of
either
“130”
for
the
6006C
or6009C,
or
“120”
is
displayed
for
the
9597B
and
9507
pedestals.
*Note:
It’s
advisable
to
have
someone
watching
the
feed
while
it’s
being
driven
as
if
the
pot
isn’t
correctly
calibrated
there
is
the
possibility
to
damage
the
assembly
if
the
LNB
hits
the
pol
motor
or
the
reflector
harness
is
coiled
around
the
feed.
7.
Observe
the
physical
alignment
of
the
feed:
The
RX
waveguide
should
be
facing
downwards
with
the
TX
reject
filter
to
the
right,
vertically
with
the
LNB
horizontally
above
the
assembly
with
the
coax
exiting
to
the
left.
Later
revisions
of
this
system
use
an
additional
length
of
waveguide
with
the
filter
above
the
assembly
horizontally,
and
the
LNB
facing
downwards
on
the
left
side
(as
shown
on
the
below
image).
Содержание 6006C